saia PCD2_M150 upload and download

ngoclan

Member
Join Date
Sep 2013
Location
vung tau
Posts
153
I want to upload a program from a saia pcd2 to modify some constants and download it again to the same plc. i have downloaded the PG5 software. when i established the connection between PC and PLC. but me upload being errors, i have a question for your help, I have found errors when I upload panel p41. those errors are shown that I send link video attach. could you help me how to fix those errors?
https://youtu.be/YlRNeVD8jY0
 
I want to upload a program from a saia pcd2 to modify some constants and download it again to the same plc. i have downloaded the PG5 software. when i established the connection between PC and PLC. but me upload being errors, i have a question for your help, I have found errors when I upload panel p41. those errors are shown that I send link video attach. could you help me how to fix those errors?
https://youtu.be/YlRNeVD8jY0
could you help me how to fix those errors?
 
Many years later, but I hope it works for someone.

For PCD1 and PCD2 plcs you want to use a lower version of Saia Project Manager PG5 Version 1.4 + Patch 15 + SAIA USB driver update works for me in windows XP and problem solved.

Also check your PCD8.K111 cable that all pins are wired correctly, if one pin is missing you won't have connection to your PLC.

PG5 download + drivers updates
https://sbc-support.com/en/product-index/archive/pg5-controls-suite/pg5-14/pg5-14-suite/
PCD8.K111 PC-PLC wiring
https://sbc-support.com/en/faq/100151/
 
Soporte

Many years later, but I hope it works for someone.

For PCD1 and PCD2 plcs you want to use a lower version of Saia Project Manager PG5 Version 1.4 + Patch 15 + SAIA USB driver update works for me in windows XP and problem solved.

Also check your PCD8.K111 cable that all pins are wired correctly, if one pin is missing you won't have connection to your PLC.

PG5 download + drivers updates
https://sbc-support.com/en/product-index/archive/pg5-controls-suite/pg5-14/pg5-14-suite/
PCD8.K111 PC-PLC wiring
https://sbc-support.com/en/faq/100151/

Buenos dias compañero me podrias apoyar con el SAIA USB driver update. Ya que no lo encontre disponible en la pagina de SBC..

Solo encontre este SComm Driver Update 1.4.321 for running PG5 V 1.4.300 on Win7/8 32 Bit and 64 Bit systems. Pero a mi parecer no es el indicado..

Gracias 🤞🏻
 

Similar Topics

hi, i have a machine with SAIA model number PCD2.M5540. Recently i am facing issue regarding the run and stop mode. i tried setting the plc to...
Replies
2
Views
1,801
Hello Friends I need to backup a SAIA PCD2 (pic attached). I have no experience with SAIA. Which software do i need? which cable? I have read...
Replies
2
Views
1,910
Gents, I have a PLC and HMI from SAIA Please, see in the attached pics and tell me how to upload the programs to the PC (PLC and HMI) Tons...
Replies
5
Views
2,271
helo sir /madam i have a old saia burgess pcd2 m110 plc.(1996) i down load the pg5 from the net and i am able to communicate .(i am able to upload...
Replies
1
Views
3,331
Hi all. I have problem with RIO moduls. 1. Can I download somwhere list of fault code? 2. e006 on RIO is lost commucation on profibus? 3. is...
Replies
0
Views
1,646