Dear All

It's late Sunday night and I am getting low on suger :)

I am trying to connect to a Sinamic drive with my serial cable as I have done many times before, but something is giving me trouble.

A few days ago I was playing around with my PC adapter USB and trying to get it to work on my Windows 10 laptop (this laptop)

So now when I am in the PG/PC interface i have the
PC.adapter.PROFIBUS.1 <active>

And I can't get it to switch to serial, what am I missing here anything, is there a process I need to kill ??

Thanks
Holmux
 
Dear All

It's late Sunday night and I am getting low on suger :)

I am trying to connect to a Sinamic drive with my serial cable as I have done many times before, but something is giving me trouble.

A few days ago I was playing around with my PC adapter USB and trying to get it to work on my Windows 10 laptop (this laptop)

So now when I am in the PG/PC interface i have the
PC.adapter.PROFIBUS.1 <active>


Well you're lucky it starte
And I can't get it to switch to serial, what am I missing here anything, is there a process I need to kill ??

Thanks


I would only guess that if it's not accepting the change it may be your serial adapter driver. But before going too far with that, try changing to any other adapters you have working and see if it accepts the change and tests OK.

Kal
 
Hi Kal

I have tried a few giving me the same result, can't get it to let go of the PC adapter
 
hmm, close PG/PC and check if s7elonls64.exe process is terminated or not. And if all else fails I usually restart my PC even though it an oldie and takes 15-20 minutes to fully load
 
Found it :)

My stupid Firewall was kicked out, I have a hole true to the S110 :)

Thanks Kal, for helping me keeping my spirit up
 

Similar Topics

Hey guys, I just wanted to see if any of the bright minds on here had any opinions on these relay interface modules. Particularly, I would love to...
Replies
1
Views
78
Hello world! The company I started working for has these valves that they ordered years ago as spares. now we have to add couple valves on...
Replies
6
Views
224
Good morning fellow sea captains and wizards, I am being asked to do the above and obtain 4 values from each slave, I know about the MRX and MWX...
Replies
32
Views
992
Does anyone know why the connection interface is greyed out and says why I can only use Teleservice instead of the other options like PN/IE? I am...
Replies
5
Views
268
I am attempting to generate a VBA script within FactoryTalk View SE to open a Google Chrome webpage (PI Vision) when an object is right-clicked...
Replies
2
Views
147
Back
Top Bottom