CP343-1 IT applets and JAVA (Borland JBuilder X)

seppeomloop

Member
Join Date
Apr 2005
Posts
1
Hi,

I have to visualize a process by using the integrated webserver of the CP343-1 IT. I'm reading the manual S7Beans / Applets for IT-CPs and i'm trying some examples, but the most examples don't work properly:
  1. When I use the default Get or Put applet, and set the language parameter and edit parameter in the HTML code, de applet works, but the edit-feature won't work properly when I double click on the applet. I tried it in different browsers, and it only works in Mozilla. So not in Netscape or internet explorer. I checked the browsers configuration and looks good. I disabled blocking pop ups etc. any idea?
  2. Another problem with the default applets: when I use the symbol parameter, add the symbol in the hardware config and the Step7 symbol editor, I always retrieve Error on the applet. So only the absolute addressing works and can't find the reason.
  3. A 3th problem: I'm trying to write an own applet by using Borland JBuilder X, but when I write the same code as shown in an example, I cant compile. I got lots of errors, JBuilder can't find the classes from the de.siemens.simaticnet.itcp-packages. I copied the packages from the CP to my project. I think it's only a problem caused by the project settings, but don't know how to resolve them.
anyone experience with this?

Thanks,

Seppe Omloop
Student KHK Geel
 
hi seppeomloo,
I was searching abaout CP343-1 Advanced Java Applets I saw you. and I need CP343-1 Advanced Java Applets. if you can send me applets , I will be happy. please hepl me. this is my e-mail adress: [email protected]. I am waiting your answer.
yours,
 

Similar Topics

Dear All, I have stored a website in this CP and some applets. One day all of a sudden all my applets stopped working and the Java Console...
Replies
1
Views
10,158
P
Hello at all, I tried to use the S7Applets for a Website that runs in the CP343-1 IT. Normal Web pages with Links to other sides are working...
Replies
4
Views
2,415
Hi, I have a customer with a S7300 from around 2013 which they link to approx 25 inverters, 3 DP to DP converters and 5 IM153 remote I/O units...
Replies
8
Views
318
I've been called to a site to assist with an ASi fault. The line has been down for a couple of weeks following a failure of the ASi power supply...
Replies
6
Views
1,295
I have an S7-300 and an HMI. The HMI is the only device that talks over Profinet through the CP343-1 module. It's run fine for a couple of years...
Replies
2
Views
502
Back
Top Bottom