Has anyone had any direct issues with the accuracy of the memory estimation in RSLogix Vs. Online with real processor Vs. RSLogix Emulate 5.

Right now I am making some fairly substantial changes to an existing system so I have been checking the calculations in the emulator. When I verify the project offline and then check the remaining memory I have 11000 words remaining, but I happened to look when "online" with the emulator and it was showing 800 words remaining, which of course is too close.

Has anyone ever noticed this "anomaly" before and which one would you trust (RSLogix offline or online with emulator)?

RSLogix V6.30.00(CPR6)
RSLogix Emulate 5 V5.00.08.00

Thanks for any insight,

Darren
 
In case anyone is interested it seems to be an issue with the emulator. The offline file (after verifying the project) was within a few words of the actual memory usage of the actual processor. Thank goodness for that. Now I can get back to work without so much stress.

Darren
 

Similar Topics

We have plc 5/30 processor in our plant. we r planning to purchase rslogix5 software for interfacing with plc 5/30.but the laptop we have lacks...
Replies
1
Views
4,612
Is this correct? A hardware (sensors) is connected to PLC5... PLC5 is linked to PC via ethernet (Or RS232c)... PC is bundled with RSView32...
Replies
2
Views
3,167
I am working in the following system and i am having the problem mentioned below please help me and solution. System: Allen Bradly-PLC-5...
Replies
2
Views
6,994
I could use some help figuring out the layout of a Remote I/O channel Diagnostic Files in a PLC5 using RSLogix5. I've attached a screen shot of...
Replies
14
Views
3,662
Hi all. I was wondering if anyone knew a way to renumber Ladder Numbers in RSLogix 5. I have deleted some of the old Program Files in my Project...
Replies
2
Views
1,534
Back
Top Bottom