Siemens Wincc installation woes

falc

Member
Join Date
Aug 2007
Location
antwerp
Posts
11
Hi

for a reason I had to uninstall wincc 6.0 and sql server 2000

but I cant reinstall sql server 2000, he says installation failed

this is the sqlstp log file.

Code:
 16:05:06 SetFileSecuritySQLAndAdmin for C:\Program Files\Microsoft SQL Server3\MSSQL$WINCC returned: 0, 0
 16:05:06 SetRegSecuritySQLAndAdmin for Software\Microsoft\Microsoft SQL Server\WINCC returned: 0, 0
 16:05:06 Begin Action: UpdateSystemPath
 16:05:06 Path successfully updated.
 16:05:06 C:\WINDOWS\Intellution;C:\Program Files\Common Files\Siemens\bin;C:\Program Files\Common Files\Siemens\Sqlany;C:\Program Files\Siemens\Step7\S7bin;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem;C:\Program Files\Microsoft SQL Server\80\Tools\BINN;C:\Program Files\Common Files\Siemens;C:\Program Files\Siemens\WinCC\Interfaces;C:\Dynamics
 16:05:06 End Action: UpdateSystemPath
 16:05:07 C:\Program Files\Microsoft SQL Server\80\Tools\Binn\cnfgsvr.exe  -F "C:\WINDOWS\sqlstp.log" -I WINCC -V 1 -M 0 -Q "Latin1_General_CI_AS" -H 1312246 -U sa -P 
 ###############################################################################
 
 
 Starting Service ...
 
 Latin1_General_CI_AS
 
 -m -Q -T4022 -T3659
 
 Connecting to Server ...
 
 driver={sql server};server=****\WINCC;UID=sa;PWD=;database=master
 
 [Microsoft][ODBC-stuurprogrammabeheer] De naam van de gegevensbron is niet gevonden en er is geen standaardstuurprogramma opgegeven
 
 driver={sql server};server=****\WINCC;UID=sa;PWD=;database=master
 
 [Microsoft][ODBC-stuurprogrammabeheer] De naam van de gegevensbron is niet gevonden en er is geen standaardstuurprogramma opgegeven
 
 driver={sql server};server=****\WINCC;UID=sa;PWD=;database=master
 
 [Microsoft][ODBC-stuurprogrammabeheer] De naam van de gegevensbron is niet gevonden en er is geen standaardstuurprogramma opgegeven
 
 SQL Server configuration failed.
 
 ###############################################################################
 
 16:05:43 Process Exit Code: (-1) 
 16:05:43 Setup failed to configure the server.   Refer to the server error logs and C:\WINDOWS\sqlstp.log for more information.
 16:05:43 Action CleanUpInstall:
 16:05:43 C:\DOCUME~1\****\LOCALS~1\Temp\SqlSetup\Bin\scm.exe  -Silent 1 -Action 4 -Service SQLAgent$WINCC
 16:05:43 Process Exit Code: (1060) De opgegeven service is geen geïnstalleerde service.
 
 16:05:43 C:\DOCUME~1\Pieter\LOCALS~1\Temp\SqlSetup\Bin\scm.exe  -Silent 1 -Action 4 -Service MSSQL$WINCC
 16:05:43 Process Exit Code: (0) 
 16:05:43 StatsGenerate returned: 2
 16:05:43 StatsGenerate (0x0,0x1,0xf000000,0x200,1033,303,0x0,0x1,0,0,0
 16:05:43 StatsGenerate -1,Pieter)
 16:05:43 Installation Failed.


I did forget to delete the previous directory.

I realy have to get this fixed soon.


thx in advance
 

Similar Topics

Hi. We purchased SIMATIC WinCC flexible 2008 Advanced SP3 and I am not able to install it. Details: - Desktop w/Intel Core2 Duo E8400 3.00 GHz...
Replies
4
Views
19,373
Cool, the boss bought me a long awaited new HP Probook Windows 7 laptop with a serial port. My (not that old) Siemens software isn't allowed to be...
Replies
15
Views
19,824
Hello colleagues, On a Siemens Multi panel (MP 377 12") of a machine (S7-300) at a customer's site, some parameters need to be changed that have...
Replies
7
Views
281
I thought I was nearly finished on this TIA Portal/s7-1212C project (famous last words)... Up until now, I'd developed the PLC/HMI such that the...
Replies
10
Views
1,510
Hi, I have a HMI which is a KTP1200 Basic. Let's suppose USER03 is logged in. How do I create a simple "Lock Screen" that appears if the screen...
Replies
2
Views
664
Back