Omron cable help C200HS-CN220-EU

geniusintraining

Lifetime Supporting Member + Moderator
Join Date
Jun 2005
Location
SC
Posts
8,274
Hello all,

I have sold a cable to someone and they are having an issue with it... not realy the cable but the connections

They have an C200H with an C200H-LK201 the cable that I sold was an C200HS-CN220-EU

He is having issues going from the 25pin? to the cable I sold (its a 9pin)

After reading some other post from gtsuport and others I can not find the answer is it just a 9 to 25 pin adapter?

Thanks
Mark
 
Thanks Panic..

I just posted on MrPLC.com and asked if they could use it, looks like they have 2 types??

Thanks again
 
GIT,
Standard 9 to 25 pin adaptor will not work.
One problem is the Signal Ground.
Standard adaptor will have SG going from Pin 5 (9pin)
to Pin 7 (25 pin).
C200HS-CN220-EU has Omron 9 pin side SG on pin 9.

Panic Mode's cable is correct.

Hope this will help.
 

Similar Topics

hello,I have a customer ask me: he want a FS-CN226,FX-CIF02,but he didn't have RS232/USB interface to connect PC instead of Touch screen That...
Replies
0
Views
1,963
Hi, all. I just got an Omron CPM2A off eBay and I need to make my own serial cable to connect it to my computer for programming. I will be...
Replies
5
Views
12,329
Hi! Has someone a pinout and/or wiring diagram for an old CQM1-CIF02 cable? Thanks!
Replies
2
Views
1,890
Please suggest me programing cable for omron plc sysmac model no. Cpm2a
Replies
1
Views
1,127
Hi. I work for an industrial machinery merchant so we have to try to get uploads from all sorts of different PLCs & HMIs. Our latest victim is an...