Posts
475
When you move your SE project what all to you need to move to shop floor PC? The Client, APP, My HMI is talking to 4 SLC's and 1 RMC, but not all or the shortcuts are communicating. They do point to the corect IP though.
Also they work from my play button on my laptop but not when I put is on the ind computer.
Yes the licence is on it.
 
Last edited:
We have 3 real big jobs going on right now. We went with SE because production needed a PC so the can get to SAP.I have to admit I wanting to get my hands on the SE software. Now if given a choice I will take ME and a PV+ over SE. There is a few features with SE I like, but overall it is the hokiest software I have ever used. I would like to see an list from everyone about all the hiccups it has. I've seen a few comments already.
 
We have 3 real big jobs going on right now. We went with SE because production needed a PC so the can get to SAP.I have to admit I wanting to get my hands on the SE software. Now if given a choice I will take ME and a PV+ over SE. There is a few features with SE I like, but overall it is the hokiest software I have ever used. I would like to see an list from everyone about all the hiccups it has. I've seen a few comments already.

VBA is pretty much broken in SE Versions 4 and up. Yes, it works, but due to "Some Issue", it is 100% unreliable at passing parameters from one display to another.

The "Numeric" and "String" input boxes just plain suck (but honestly, they have in every single version of RSView ever).

Communications is not robust, nor are communications issues smoothly recoverable. Redundancy is horrendous.

Patches are very poorly implemented (but better then they used to be).

Installation is a nightmare. Versioning is a nightmare.

The "Recipe" system pretty much bites, much better to roll your own.

I use it extensively, but it is still in pre-alpha as far as I'm concerned.
 

Similar Topics

Hi all, Attached below is an example of what is happening to our existing SCADA. It seems after patching some Rockwell Software that I thought...
Replies
9
Views
319
The client has an application that when communication between the PLC and the Factory Talk VIEW supervisory fails, the object in the supervisory...
Replies
5
Views
284
Hello all, I am looking for a way to have a user get logged out after an X amount of time because to default so that user privilages are no...
Replies
4
Views
586
Hello everybody. I was wondering if there is a way in FTVIEW Studio to close ) view after x min without interaction . My issue is the following...
Replies
2
Views
363
Is there a way to choose the base font in ME. Text in the Arial Unicode MS which is the default font on my FTVS doesnt show up properly on a...
Replies
1
Views
676
Back
Top Bottom