Panel View Plus Print Screen

Whitey

Member
Join Date
Jul 2009
Location
Brisbane
Posts
2
Hello Everybody,
Has anyone used the Panel View Plus Print screen feature recently with a HP printer? I tried for the first time today.
I read the tech notes selected a HP printer which supports PCL3 (HP D2560), upgraded the firmware in the HMI to >5. What happens is when I press the print screen button the printer responds by flashing the power button as if receiving data only it just continues to flash for about 5 minutes then stops. No printing done. I cannot find anything of use in the manual or driver setup for the printer. Any thoughts would be appreciated.

Thanks
 
I have done this with a PV+ 1000. I had to find a printer that supports PCL3 also, was not that easy, ended up getting a 2nd one off a local buy/sell site.

I don't have access to the PV config setup, but do recall having to do some settings in there. Have you had a look at the settings in the config screen?

What method are you using, serial/ethernet/USB? I used USB.

You can also read/write the status to print remotely using Global connections, the Display Print Active is set when the display is being printed, this could assist in confirming that the PV+ is trying to print.
 
Yes I am using USB. Yes there was some basic setup needed in the PV Config setup. Thanks for the tip as the print is active however there must be a time out that cancels it after about 5 minutes. I think you are right. I will need to track down an older printer as PCL3 is becoming out of date and perhaps there is a problem with this printer being both PCL3 and GUI. I will try and track down an older unit even if it is just to prove the point.
 

Similar Topics

Am asking if we can upgrade sd ram and cf card of panel view plus ab by a normal sd ram and cf card but Allen Bradley to save cost because in ab...
Replies
9
Views
280
Good morning, I have a question, I would like to know if I can send an Excel file to an email from my panel view and see how it is possible to...
Replies
1
Views
154
I want to run a factory talk view ME project in a Panel View Plus 7 Performance HMI. The project was developed in a 'Windows 7 Professional 64 bit...
Replies
5
Views
332
I purchased a used PanelView Plus 1000 to learn get familiar with the software. Seems to be a pretty popular HMI. I can ping the HMI but I cannot...
Replies
6
Views
883
Hello, hope yall are doing well. I have a HMI program where I need to add a "GoToDisplay" button, so when this button is pressed, it goes to a...
Replies
5
Views
880
Back
Top Bottom