Hi all.

One of our clients is having issues with asset center and rs5000.

All RS projects (PLC,SLC,CLX etc) are in asset center. When performing a get or check out on any RS5000 program we see the splash screen, which disappears after a minute. We can see in process explorer that RS5000.exe is running (without a window) then some 20+ minutes later we get prompted to enter logon details for asset center and the file opens. The symptoms are identical across 3 development machines.

Any ideas on where to start looking for solutions?

Any help greatly appreciated.

Regards Dave
 
Finally resolved the issue.

All the machines have dual network cards and were struggling to resolve the machine names (a problem that only occurred after installing V20 logix5000)

We have resolved the issue by editing the hosts file on all machines (1 server and 4 clients)

Fingers crossed.

Dave
 

Similar Topics

Hi Everyone, We are getting an error window whenever I opened the Factory talk asset center Application as "The Database size is critical level...
Replies
0
Views
336
Not able to go online with some older 500 series processors. I have went online with the processors in the past, something changed. I get "no...
Replies
0
Views
983
A recent post on PLCS.net reminded me that we have our PLCs on Asset Center, getting backups done periodically ... but our Devicenet, Controlnet...
Replies
0
Views
1,332
We just purchased Asset Center and we will be attending a class on it in early march. I was reading up on its setup and have a few questions. We...
Replies
2
Views
4,182
I am in the progress of setting up a factory talk asset center application. I am a little confused on the whole sequence. I was hoping someone...
Replies
0
Views
1,352
Back
Top Bottom