Search: Posts Made By: Rob S.
Forum: LIVE PLC Questions And Answers December 4th, 2019, 06:51 PM
Replies: 2
Views: 283
Posted By Rob S.
Do you know any Electric Actuaters capable of withstanding 180 degree F

Good Evening ,

Do you folks know of any Electric Actuaters that can handle about 180 Degrees F ? What are the common brands of Actuaters ?

Thanks in advance ,
Forum: LIVE PLC Questions And Answers November 20th, 2019, 09:24 AM
Replies: 9
Views: 747
Posted By Rob S.
RS Logix 5000- Sub Routine rung outputs will not activate. JSR is active .

Good Morning ,

I'm merging another RS Logix 5000 PLC program ( CompactLogix ) into another . Everything is working great except this one sub routine . The timers work , but not the outputs...
Forum: LIVE PLC Questions And Answers November 18th, 2019, 07:30 PM
Replies: 1
Views: 180
Posted By Rob S.
Dog FactoryTalk View-Difference between Test Application and Create Runtime

Good Evening ,

I'm working on a FactoryTalk View ME project and I have my communication path setup with my L33 CompactLogix and when I do the test application it runs great , but when I Create...
Forum: LIVE PLC Questions And Answers October 29th, 2019, 02:01 PM
Replies: 4
Views: 863
Posted By Rob S.
Thanks for your thoughts and advice. ...

Thanks for your thoughts and advice.

How would you define ......
Active
Active Mature
End of Life

For 2020 , I plan on replacing alot of SLC 500's with CompactLogix. How long
can I...
Forum: LIVE PLC Questions And Answers October 27th, 2019, 06:58 PM
Replies: 4
Views: 863
Posted By Rob S.
The future of the Powerflex 4 and Powerflex 40 Drives

Good Evening ,

We have a ton of Powerflex 40 and Powerflex 4 Drives in the plant. What is the future of the Powerflex 40's and 4's ?

What about the Powerflex 70' and 700's ?

Thanks ,
Forum: LIVE PLC Questions And Answers September 29th, 2019, 02:57 PM
Replies: 0
Views: 200
Posted By Rob S.
PowerFlex 70- Issues with replacing the drive with different version with DeviceNet

Good Afternoon ,

We have a number of PowerFlex 70 Drives that are on DeviceNet . These are older drives so when we replace a drive , we have a difficult time getting them to communicate on...
Forum: LIVE PLC Questions And Answers September 27th, 2019, 10:18 AM
Replies: 7
Views: 379
Posted By Rob S.
Ok. So really this Selector Switch is only a...

Ok. So really this Selector Switch is only a image , right ? So I would need to
put a pushbutton , with a tag attached , under this Selector Switch , correct ?

Thanks
Forum: LIVE PLC Questions And Answers September 27th, 2019, 09:12 AM
Replies: 7
Views: 379
Posted By Rob S.
Yea. That's a good suggestion . Thanks

Yea. That's a good suggestion . Thanks
Forum: LIVE PLC Questions And Answers September 27th, 2019, 08:49 AM
Replies: 7
Views: 379
Posted By Rob S.
FactoryTalk View ME-Symbol Factory Selector Switch.Can you visually make that toggle?

Good Morning ,

I'm working on a FactoryTalk View ME project , and I'm using , out of the Symbol Factory , ( in the 3D Pushbutton group ) a Selector Switch . I guess you can make that visually...
Forum: LIVE PLC Questions And Answers September 20th, 2019, 09:25 AM
Replies: 2
Views: 281
Posted By Rob S.
PowerFlex 753 and CompactLogix L33- What is DeviceLogix ?

Good Morning ,

I have a CompactLogix L33 and several Powerflex 753 Drives ( Ethernet ).
In my RS Logix 5000 Tree I have all the drives. In those drives I have....

Slot 4- Ethernet / IP ...
Forum: LIVE PLC Questions And Answers September 17th, 2019, 12:37 PM
Replies: 4
Views: 399
Posted By Rob S.
Rockwell Panelview Plus Replacement for a Old Panelview 2711-T6C20L1

Good Afternoon ,

I have 3 old Panelview Terminals that I need to replaced. Could you tell me
the replacement for the Panelview Terminal 600 2711-T6C20L1 with what model Panelview Plus 7 ?
...
Forum: LIVE PLC Questions And Answers September 4th, 2019, 02:06 PM
Replies: 6
Views: 349
Posted By Rob S.
Rockwell Automation Safety-Will a TLS-ZGD2 Locking Switch work with a 440C-CR30 Relay

Good Afternoon ,

I putting a Rockwell Automation Safety System. I was wondreing if a
TLS-Z GD2 Guard Locking Switch would work well with a 440C-CR30-22 BBB
Safety Relay that is programmed...
Forum: LIVE PLC Questions And Answers August 22nd, 2019, 04:40 PM
Replies: 0
Views: 246
Posted By Rob S.
FactoryTalk ME -The correct version of the Microsoft XML Parser is not installed ?

Good Afternoon ,

When I open FactoryTalk View ME . I go to open it up and I get the following message. " The correct version of the Microsoft XML Parser is not installed. Version 4 is...
Forum: LIVE PLC Questions And Answers August 12th, 2019, 08:02 AM
Replies: 20
Views: 1,420
Posted By Rob S.
New Laptop.No serial ports.Looking for best USB to Serial cable to SLC 500

Good Morning ,

I just purchased a Windows 10 Hp Laptop. Of course no serial ports , but 3 USB ports . Need a USB to Serial cable to go to SLC 500 PLC . What is the correct Rockwell Automation...
Forum: LIVE PLC Questions And Answers June 16th, 2019, 09:40 AM
Replies: 0
Views: 337
Posted By Rob S.
CEIA Metal Detectors - Can they integrate into RS Logix 5000 ( CompactLogix )

Good Morning , and Happy Fathers Day ,

We have a lot of CEIA Metal Detectors and we would like to capture this data into our IPM Stations . If you have CEIA Metal Detectors, have you been...
Forum: LIVE PLC Questions And Answers June 11th, 2019, 04:51 AM
Replies: 16
Views: 1,656
Posted By Rob S.
How can you determine the RPM of a 3 Phase motor without a nameplate ?

Good Morning ,

We had a 3 phase motor go bad yesterday . The motor had no nameplate .
How can you determine what RPM ( or how many poles ) without a nameplate .

Any links or...
Forum: LIVE PLC Questions And Answers June 6th, 2019, 06:57 AM
Replies: 28
Views: 2,767
Posted By Rob S.
We know that the price of the older and phased...

We know that the price of the older and phased out AB Automation is increasing , but do you think that the price of the support contract is increasing , for these components ?

Thanks ,
Forum: LIVE PLC Questions And Answers June 5th, 2019, 09:15 PM
Replies: 28
Views: 2,767
Posted By Rob S.
Future of the AB MicroLogix and RS Logix 500 ?

Good Evening ,

What is the future of MicroLogix PLC's and RS Logix 500 software ? I know
the SLC 500 is quickly being phased out . I would like to stick with one software package , such...
Forum: LIVE PLC Questions And Answers May 13th, 2019, 03:19 PM
Replies: 13
Views: 916
Posted By Rob S.
Possible Static on Conveyor Belt causing Metal Detector Issues..... Possible ?

Good Afternoon ,

I just came out of a meeting , and the subject came up , about static buildup on a conveyor belt causing a metal detector to go "Haywire" . Have any of you had this problem...
Forum: LIVE PLC Questions And Answers May 13th, 2019, 03:12 PM
Replies: 5
Views: 388
Posted By Rob S.
Thanks so much. I will mess around with it in a...

Thanks so much. I will mess around with it in a few weeks.
Forum: LIVE PLC Questions And Answers May 13th, 2019, 10:50 AM
Replies: 5
Views: 388
Posted By Rob S.
Messaging-SLC 500 to/from CompactLogix ?

Good Morning ,

We are getting ready to do a small project with a Cognex Vision System.
We have a SLC 500 , controlling the operation , but since we need to eventually convert to the Logix...
Forum: LIVE PLC Questions And Answers April 23rd, 2019, 04:03 AM
Replies: 6
Views: 634
Posted By Rob S.
Thanks for your thoughts and information. Where...

Thanks for your thoughts and information. Where would I find this S:FS bit in the program . I recall seeing something similar in RS Logix 500 ( SLC ) in the controller folder . I will check online...
Forum: LIVE PLC Questions And Answers April 22nd, 2019, 03:26 PM
Replies: 6
Views: 634
Posted By Rob S.
Servo positions not updating.Could you please explain this code ?

Good Afternoon ,

We have a new machine from Italy , and for some reason , the servo actual positions quit updating on the HMI. I looked at the tag in the "connection" tab in Numeric Display...
Forum: LIVE PLC Questions And Answers April 15th, 2019, 07:52 PM
Replies: 6
Views: 465
Posted By Rob S.
Thanks so much for your help. I'm better at...

Thanks so much for your help. I'm better at creating my own program , then trying to figure , ok , why are they doing this , this way . With your help , it will give me a better perspective to look...
Forum: LIVE PLC Questions And Answers April 15th, 2019, 01:45 PM
Replies: 6
Views: 465
Posted By Rob S.
SLC 500- Need help understanding N106:[N7:10] in a MOV

Good Afternoon ,

I'm sorry. But I'm struggling to understand this combination of integers
in this MOV , and really anywhere else this scheme is being used.

N106:[N7:10] - With your...