Search: Posts Made By: Eduardo Pelegrin
Forum: LIVE PLC Questions And Answers May 2nd, 2019, 02:54 PM
Replies: 3
Views: 549
Posted By Eduardo Pelegrin
Thanks

Thanks
Forum: LIVE PLC Questions And Answers April 5th, 2019, 08:37 AM
Replies: 3
Views: 549
Posted By Eduardo Pelegrin
S7TCP driver license

Hi everyone, finally I succeded to communicate Citect 2016 with S7 1516 PLC, part number 6ES7 516-3AN01-0AB0 (firmware versión 2.1), but I am having a WARNING message . It says that I am running a...
Forum: LIVE PLC Questions And Answers February 12th, 2019, 08:09 AM
Replies: 6
Views: 738
Posted By Eduardo Pelegrin
Hi sigmadelta. I am getting #BAD when I try to...

Hi sigmadelta. I am getting #BAD when I try to read a REAL value from DB20 in S7 1500 PLC. What is the meaning of "<symbolic name>" for address format?. Do you have a real example of Citect...
Forum: LIVE PLC Questions And Answers February 12th, 2019, 06:12 AM
Replies: 6
Views: 738
Posted By Eduardo Pelegrin
Thanks a lot

Thanks a lot
Forum: LIVE PLC Questions And Answers February 11th, 2019, 02:33 PM
Replies: 6
Views: 738
Posted By Eduardo Pelegrin
Thanks, sigmadelta. Yes, I have that driver...

Thanks, sigmadelta. Yes, I have that driver already, but what I need is what should I have to set up in Citect to get the communication with the S7 1500 PLC using this driver
Regards EP
Forum: LIVE PLC Questions And Answers February 11th, 2019, 11:09 AM
Replies: 6
Views: 738
Posted By Eduardo Pelegrin
Communicate Citect 2016 with Siemens S7 1500 with S7TCP driver

I need to know the steps to communicate Citect 2016 with Siemens S7 1500 using S7TCP driver.
Thanks
Forum: LIVE PLC Questions And Answers June 10th, 2016, 09:17 AM
Replies: 4
Views: 931
Posted By Eduardo Pelegrin
S7 TIME format and Citect

Hello, I am working with the FB 41 (CONT_C, Continuous Control) for P+I control. I use Citect as SCADA. To address GAIN parameter I have not problem because it is in REAL Data type, but the I...
Forum: LIVE PLC Questions And Answers September 12th, 2008, 11:07 AM
Replies: 0
Views: 752
Posted By Eduardo Pelegrin
Smile Freeze digital outputs on S7 300

Hello,
I have found that in S7 200 there is a System Block tool where you can select and Freeze in last state of Digital Outputs when PLC transitions from RUN to STOP Mode. I would like to know how...
Forum: LIVE PLC Questions And Answers March 1st, 2005, 10:03 AM
Replies: 1
Views: 2,240
Posted By Eduardo Pelegrin
Arrow GE Fanuc 9030 optical communication

Hello,
We have some GE Fanuc PLCs 9030 series with CPU 374. I want to know if this type of PLC has a communication card with fiber optic connection. If not,please advise how to connect the PLC to...
Forum: LIVE PLC Questions And Answers September 22nd, 2004, 01:52 PM
Replies: 1
Views: 2,261
Posted By Eduardo Pelegrin
S5 115U as DP slave

Hello guys,I am communicating a S7-300 PLC as a master with one S5 115U(IM 308C) as slave using Profibus DP.I would like to be able to read all four analog inputs cards (16 inputs each) at the...
Forum: LIVE PLC Questions And Answers July 1st, 2004, 03:16 PM
Replies: 2
Views: 13,553
Posted By Eduardo Pelegrin
S7 300 analog output

Hello,
Could somebody tell me which FC or SFC on S7 300 PLC do I have to use to send a 4-20 mA signal through an analog ouput card?. In S5 115 PLC I have used the FB 251. Do I have to create my own...
Forum: LIVE PLC Questions And Answers June 2nd, 2004, 06:29 AM
Replies: 2
Views: 1,200
Posted By Eduardo Pelegrin
S5 Analog reading

Thanks Daniel. Your suggestion is very useful.

Eduardo
Forum: LIVE PLC Questions And Answers June 1st, 2004, 02:28 PM
Replies: 2
Views: 1,200
Posted By Eduardo Pelegrin
S5 Analog Reading

I need this help.FB 250 is used in S5(115U) PLC for analog readings. Parameters UGR and OGR are used to set Min and Max Ranges.I can see that the only way of setting these parameters is by mean of KF...
Forum: LIVE PLC Questions And Answers April 29th, 2004, 07:45 AM
Replies: 1
Views: 1,650
Posted By Eduardo Pelegrin
DP Master System

In a DP Master System, the Master(S7 300 PLC) has to be placed always at the one end of the Bus or it could be placed at any place of the DP Master System?. Your help will be appreciated.

Regards,...
Forum: LIVE PLC Questions And Answers March 25th, 2004, 01:35 PM
Replies: 18
Views: 7,446
Posted By Eduardo Pelegrin
Thanks everybody for your help. Best...

Thanks everybody for your help.

Best regards,
Ed
Forum: LIVE PLC Questions And Answers March 24th, 2004, 02:21 PM
Replies: 18
Views: 7,446
Posted By Eduardo Pelegrin
Retentive On-delay Timer for S7-300

It seems to be a very straightforward question but I need a help.For S7 200 Micro PLCs there is a Retentive On-Delay timer(TONR)
that satisfies the application I want to implement, but in S7 300...
Forum: LIVE PLC Questions And Answers March 24th, 2004, 12:11 PM
Replies: 11
Views: 16,485
Posted By Eduardo Pelegrin
Daniel, My email address is...

Daniel, My email address is epelegrin@moanickel.com.cu

Thanks.
Eduardo.
Forum: LIVE PLC Questions And Answers March 24th, 2004, 12:08 PM
Replies: 11
Views: 16,485
Posted By Eduardo Pelegrin
Thanks a lot Daniel I will work on it. I will let...

Thanks a lot Daniel I will work on it. I will let you know my results.
May I contact you through your email address?
Regards,
Edauardo
Forum: LIVE PLC Questions And Answers March 24th, 2004, 10:55 AM
Replies: 11
Views: 16,485
Posted By Eduardo Pelegrin
Thanks a lot Nif and Daniel,at the time when I...

Thanks a lot Nif and Daniel,at the time when I wanted to write this reply I had a little problem in my computer, so I do not know if my reply was sent out.According to the valuable information you...
Forum: LIVE PLC Questions And Answers March 23rd, 2004, 02:50 PM
Replies: 11
Views: 16,485
Posted By Eduardo Pelegrin
Thanks a lot Daniel, it is nice to be in contact...

Thanks a lot Daniel, it is nice to be in contact with you again. I will try it and I will let you know how the things are going.

Best regards,
Eduardo
Forum: LIVE PLC Questions And Answers March 23rd, 2004, 10:43 AM
Replies: 11
Views: 16,485
Posted By Eduardo Pelegrin
Redundancy on S7 300 PLCs

I would like to know the best way to make two S7 300 PLCs redundant.
Each PLC would have the same slaves( on S5 115U PLC through IM 308, one ET 200U trough IM318 and one OP37). The S7 300 PLCs will...
Forum: LIVE PLC Questions And Answers April 26th, 2003, 03:59 PM
Replies: 2
Views: 5,086
Posted By Eduardo Pelegrin
S7 300 PLC with S5 95U PLC

Your are correct RRobbins. I am using a S7-315 2DP and the FDL version of the 95U. I will appreciate your help,

Thanks,
Eduardo
Forum: LIVE PLC Questions And Answers April 25th, 2003, 10:10 AM
Replies: 2
Views: 5,086
Posted By Eduardo Pelegrin
S7 300 PLC with S5 95U PLC

I have tried to communicate S7 300 PLC with S5 115U PLC through Free Layer Link without problems. I would like to do the same with the S5 95U. So far I have not had any success with this...