Search: Posts Made By: Operaghost
Forum: LIVE PLC Questions And Answers Yesterday, 02:17 PM
Replies: 14
Views: 239
Posted By Operaghost
Must be on your end. I can access the sites. ...

Must be on your end. I can access the sites.

OG
Forum: LIVE PLC Questions And Answers Yesterday, 11:16 AM
Replies: 4
Views: 133
Posted By Operaghost
Ok, so we see the button and the tag associated...

Ok, so we see the button and the tag associated with it. What about the logic in your PLC to reset your values? The button should be used to trigger reset logic in the PLC rather than trying to have...
Forum: LIVE PLC Questions And Answers Yesterday, 09:34 AM
Replies: 15
Views: 898
Posted By Operaghost
So as discussed, a router or a NAT device is...

So as discussed, a router or a NAT device is probably the best way to go here.

Consider that a router will connect the two networks. It could potentially allow any device on either network to talk...
Forum: LIVE PLC Questions And Answers June 22nd, 2022, 09:08 AM
Replies: 5
Views: 476
Posted By Operaghost
If you want to see the code for the existing...

If you want to see the code for the existing instructions double-click over on the rung number. That will show you the ASCII code. When you type in your code can you see the text then?

If however,...
Forum: LIVE PLC Questions And Answers June 20th, 2022, 09:35 AM
Replies: 2
Views: 325
Posted By Operaghost
One PC may have up to two HMI servers....

One PC may have up to two HMI servers. Functionally I don't believe it will prevent you from adding a third. I seem to recall running more than two HMI servers for demonstration purposes.

But,...
Forum: LIVE PLC Questions And Answers June 20th, 2022, 09:28 AM
Replies: 2
Views: 352
Posted By Operaghost
For some reason, the internal bell function...

For some reason, the internal bell function stopped working with version 6.0. Here is the Tech Note describing the issue.
...
Forum: LIVE PLC Questions And Answers June 9th, 2022, 11:25 AM
Replies: 2
Views: 290
Posted By Operaghost
And you can always use copy & paste too. ...

And you can always use copy & paste too.

OG
Forum: LIVE PLC Questions And Answers May 26th, 2022, 02:54 PM
Replies: 1
Views: 334
Posted By Operaghost
Objects ==> Diagnostic Viewer It isn't...

Objects ==> Diagnostic Viewer

It isn't exactly the same window but it gets the job done.

OG
Forum: LIVE PLC Questions And Answers May 25th, 2022, 09:39 AM
Replies: 16
Views: 1,707
Posted By Operaghost
When a device configured to use DHCP fails to...

When a device configured to use DHCP fails to obtain an IP address from a DHCP server they will default to what Microsoft called an Automatic Private IP Address (APIPA). I think they started this...
Forum: LIVE PLC Questions And Answers May 23rd, 2022, 09:42 AM
Replies: 16
Views: 1,707
Posted By Operaghost
I suspect VNC will be reenabled at some point...

I suspect VNC will be reenabled at some point with a firmware update. Whatever updates they did behind the scenes probably affected the VNC tool and prevented it from working properly. Doesn't help...
Forum: LIVE PLC Questions And Answers May 23rd, 2022, 09:34 AM
Replies: 7
Views: 675
Posted By Operaghost
Well that would be weird, changing the name on a...

Well that would be weird, changing the name on a minor revision. It was actually version 21.0 where the name changed.

OG
Forum: LIVE PLC Questions And Answers May 19th, 2022, 12:05 PM
Replies: 26
Views: 1,331
Posted By Operaghost
To be clear, what you described is not the same...

To be clear, what you described is not the same as what I mentioned.

You must go: PROG ==> RUN ==> PROG (clears fault)
You described PROG ==> RUN ==> REMOTE (does nothing)

Maybe you did it...
Forum: LIVE PLC Questions And Answers May 19th, 2022, 09:16 AM
Replies: 26
Views: 1,331
Posted By Operaghost
The flashing red light means there is a fault in...

The flashing red light means there is a fault in the controller. Cycling power won't necessarily clear the fault. That only works if the controller is configured to reload its program from that...
Forum: LIVE PLC Questions And Answers May 18th, 2022, 10:58 PM
Replies: 7
Views: 675
Posted By Operaghost
I guess I should have said version 14 was not...

I guess I should have said version 14 was not publicly available.

OG
Forum: LIVE PLC Questions And Answers May 18th, 2022, 05:02 PM
Replies: 7
Views: 675
Posted By Operaghost
I think significant versions I have used and come...

I think significant versions I have used and come across included: 13, 15-21, 24, 28, 30-34.

There wasn't a 14 or 22. 23 was a rebadged 21. 25-27 I don't recall ever running across in the field....
Forum: LIVE PLC Questions And Answers May 17th, 2022, 10:10 AM
Replies: 16
Views: 1,218
Posted By Operaghost
The status bits on the MSG operate a little...

The status bits on the MSG operate a little differently than on other instructions. The EN in particular.

The EN bit turns on when the logic ahead of it goes true. That's normal of course. It...
Forum: LIVE PLC Questions And Answers May 16th, 2022, 09:33 AM
Replies: 9
Views: 1,158
Posted By Operaghost
There's a whole lot going on here... In...

There's a whole lot going on here...


In my experience, the demo mode runs for two continuous hours and then the client shuts down. Not the computer itself. I seem to recall just restarting the...
Forum: LIVE PLC Questions And Answers May 15th, 2022, 07:04 PM
Replies: 6
Views: 444
Posted By Operaghost
Perhaps it is easier than all this... The .MER...

Perhaps it is easier than all this... The .MER must be in a specific folder for your PV to see it. It must be in this folder:

\Rockwell Software\RSViewME\Runtime

OG
Forum: LIVE PLC Questions And Answers May 13th, 2022, 09:38 AM
Replies: 4
Views: 753
Posted By Operaghost
There are several things that could prevent...

There are several things that could prevent conversion. There are many features and modules that have been added since version 19. Using any of those could prevent conversion from being successful....
Forum: LIVE PLC Questions And Answers May 9th, 2022, 09:31 AM
Replies: 7
Views: 1,278
Posted By Operaghost
And then after you right-click on the address and...

And then after you right-click on the address and select to edit the description, you can select Instruction or Address. But you have to right-click on the address as Nova5 mentioned, to get started....
Forum: LIVE PLC Questions And Answers May 6th, 2022, 11:24 AM
Replies: 4
Views: 602
Posted By Operaghost
Is your new input only being used in that routine...

Is your new input only being used in that routine after the IIM, or is it being used elsewhere? The concern with the IIM is that your data could change mid scan.

If you only want to remove the one...
Forum: LIVE PLC Questions And Answers May 5th, 2022, 02:31 PM
Replies: 7
Views: 1,134
Posted By Operaghost
Sometimes a programmer will include the RET for...

Sometimes a programmer will include the RET for clarity so that anyone looking at that code will know that the logic will return back from where it was called.

There are some uses for the RET...
Forum: LIVE PLC Questions And Answers May 5th, 2022, 09:25 AM
Replies: 15
Views: 1,842
Posted By Operaghost
And for anyone considering using VMs, a server...

And for anyone considering using VMs, a server operating system is not required to use virtual machines. It may be JZerb's preference (and I'm sure others too), but it is not required.

OG
Forum: LIVE PLC Questions And Answers May 4th, 2022, 05:25 PM
Replies: 13
Views: 849
Posted By Operaghost
Loved Mudbone... "Damn, this water's cold...Yeah,...

Loved Mudbone... "Damn, this water's cold...Yeah, and it's deep too" is one of the funniest lines for me still to this day.

OG
Forum: LIVE PLC Questions And Answers May 4th, 2022, 05:18 PM
Replies: 13
Views: 849
Posted By Operaghost
:thumb: OG