Forum: LIVE PLC Questions And Answers July 11th, 2018, 02:29 PM
Replies: 6
Views: 513
Posted By nehpets
K is used to denote a constant, in this case K-1...

K is used to denote a constant, in this case K-1 means a constant of minus 1, this would give a value of 65535 in 16 bit unsigned integer.


Steve
Forum: LIVE PLC Questions And Answers June 26th, 2018, 09:32 AM
Replies: 12
Views: 588
Posted By nehpets
Dave!

Dave!
Forum: LIVE PLC Questions And Answers June 22nd, 2018, 03:55 PM
Replies: 8
Views: 521
Posted By nehpets
Check out EUROTHERM NANODAC Steve

Check out EUROTHERM NANODAC


Steve
Forum: LIVE PLC Questions And Answers June 16th, 2018, 04:21 PM
Replies: 5
Views: 465
Posted By nehpets
I was always lead to believe that the S:FS flag...

I was always lead to believe that the S:FS flag was a global flag, although each program had its own associated S:FS, given that, I would say that the S:FS flag would be initiated as its associated...
Forum: LIVE PLC Questions And Answers June 12th, 2018, 10:12 AM
Replies: 18
Views: 1,205
Posted By nehpets
+1 for Daba's method, I always generate my own...

+1 for Daba's method, I always generate my own dummy and shorting flags (usually Steve_flag1, 2, etc). It is easier to cross ref to find.
If I remember correctly you can disable the shorted branch...
Forum: LIVE PLC Questions And Answers May 26th, 2018, 04:05 AM
Replies: 20
Views: 1,100
Posted By nehpets
I'm not sure this will help but it's the formula...

I'm not sure this will help but it's the formula I used recently to acertain the volume in a horizontal eliptical tank.


If the height of the tank is A, the width of the tank B, and the height of...
Forum: LIVE PLC Questions And Answers May 18th, 2018, 04:35 PM
Replies: 3
Views: 374
Posted By nehpets
Welcome Check in the project window under...

Welcome
Check in the project window under display unit, system area you will find addresses used for control and indication functions, there should be a 'change to screen' with a word address...
Forum: LIVE PLC Questions And Answers May 5th, 2018, 02:34 AM
Replies: 5
Views: 600
Posted By nehpets
Welcome, You could try downloading the...

Welcome,
You could try downloading the Mitsubishi manual JY997D16701, it's the analogue control manual for the FX range of PLC's and is invaluable for analogue control, it also has many programming...
Forum: LIVE PLC Questions And Answers April 28th, 2018, 11:56 AM
Replies: 15
Views: 659
Posted By nehpets
Just a little confused, a SDE1-V1-G2-HQ4-C-P2-M8...

Just a little confused, a SDE1-V1-G2-HQ4-C-P2-M8 is a two PnP digital output unit not analogue.
Forum: LIVE PLC Questions And Answers April 18th, 2018, 09:50 AM
Replies: 11
Views: 502
Posted By nehpets
First off the plc in the screen shot is offline,...

First off the plc in the screen shot is offline, second, is the OTE/OTL being unlatched elsewhere in the program, or, is it a bit within a word and that word being written to elesewhere?

Steve
Forum: LIVE PLC Questions And Answers March 21st, 2018, 11:46 AM
Replies: 13
Views: 565
Posted By nehpets
Or just place an unconditional rung with a MOV 0...

Or just place an unconditional rung with a MOV 0 to StationCmd above your rung with the MOV

Steve
Forum: LIVE PLC Questions And Answers March 5th, 2018, 04:44 PM
Replies: 15
Views: 1,150
Posted By nehpets
TRUE / FALSE HIGH / LOW ON / OFF ENERGISED...

TRUE / FALSE
HIGH / LOW
ON / OFF
ENERGISED / DE-ENERGISED
ACTIVE / INACTIVE


Steve
Forum: LIVE PLC Questions And Answers February 28th, 2018, 09:21 AM
Replies: 15
Views: 915
Posted By nehpets
I'm assuming this is for CIP (clean in place),...

I'm assuming this is for CIP (clean in place), which conductivity meter is it (manufacturer & model), maybe we can help with a little more info given the confusion?

Steve
Forum: LIVE PLC Questions And Answers February 27th, 2018, 10:01 AM
Replies: 15
Views: 915
Posted By nehpets
I would be mindful that US fluid measures are...

I would be mindful that US fluid measures are different fron Imperial fluid measures 1 US fluid pint = 16 US fluid oz, whereas 1 Imperial pint = 20 Imperial fluid oz.

Steve
Forum: LIVE PLC Questions And Answers February 27th, 2018, 09:54 AM
Replies: 7
Views: 818
Posted By nehpets
I've never used a compare function with the logo...

I've never used a compare function with the logo the best I can come up with is this, the output counter is set to 10 & the reset counter is set to 11

Steve
Forum: LIVE PLC Questions And Answers February 26th, 2018, 10:59 AM
Replies: 7
Views: 818
Posted By nehpets
Send the output to a 'M' flag and feed back to...

Send the output to a 'M' flag and feed back to the reset input on the counter.

Steve
Forum: LIVE PLC Questions And Answers February 20th, 2018, 10:18 AM
Replies: 25
Views: 1,350
Posted By nehpets
When moving activations via Evmovecf on windows7...

When moving activations via Evmovecf on windows7 upward you need to run as administrator otherwise the activations are removed from source drive but don't appear on destination drive.

Steve
Forum: LIVE PLC Questions And Answers February 16th, 2018, 09:53 AM
Replies: 10
Views: 474
Posted By nehpets
This is not restricted to Siemens you will find a...

This is not restricted to Siemens you will find a lot of modern HMI's (many Windows based firmware) will not upload to an editable file unless the project file has also been downloaded along with the...
Forum: LIVE PLC Questions And Answers January 7th, 2018, 07:55 AM
Replies: 36
Views: 2,454
Posted By nehpets
Minimum four hours + travel + milage around 300 ...

Minimum four hours + travel + milage around 300

Steve
Forum: LIVE PLC Questions And Answers December 1st, 2017, 01:29 PM
Replies: 9
Views: 567
Posted By nehpets
Have a look at this. Steve

Have a look at this.

Steve
Forum: LIVE PLC Questions And Answers November 28th, 2017, 10:21 AM
Replies: 4
Views: 667
Posted By nehpets
I was recently quoted for a lifetime development...

I was recently quoted for a lifetime development licence as an end user - 14,000.00

Steve
Forum: LIVE PLC Questions And Answers November 11th, 2017, 05:07 AM
Replies: 2
Views: 438
Posted By nehpets
Vijeo Designer

I am starting to get to grips with Scheider PLC's/HMI's, however I have a question that I cannot find a definative answer to, so I'm hoping someone out there can put me right.

I have created a...
Forum: LIVE PLC Questions And Answers November 10th, 2017, 11:23 AM
Replies: 7
Views: 603
Posted By nehpets
The standard, out of the box timers for this unit...

The standard, out of the box timers for this unit have a time base of 100mS, you don't say what time period you hope to achieve, but given that the time base is 100mS, K144000 would suggest you...
Forum: LIVE PLC Questions And Answers October 31st, 2017, 05:15 PM
Replies: 4
Views: 395
Posted By nehpets
Just found this, it may be a replacement battery....

Just found this, it may be a replacement battery.

http://www.allbatteries.co.uk/automaton-battery/telemecanique/tsxbat4903-ram.html

Steve
Forum: LIVE PLC Questions And Answers October 31st, 2017, 04:37 PM
Replies: 4
Views: 395
Posted By nehpets
You could try here, the battery you require is...

You could try here, the battery you require is AZ1 AQ0006, but I'm not sure Schneider supports these any longer.

https://www.mroelectric.com/blog/modicon-batteries/

Steve