You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 28
Search took 0.01 seconds.
Search: Posts Made By: ZestyMozzarella
Forum: LIVE PLC Questions And Answers December 9th, 2019, 02:52 PM
Replies: 3
Views: 584
Posted By ZestyMozzarella
I would second Wasan. If the Schneider PLC...

I would second Wasan. If the Schneider PLC supports the Modbus TCP protocol, it is likely the best way to exchange the information between each PLC. I got a Siemens guide here that shows an example...
Forum: LIVE PLC Questions And Answers December 5th, 2019, 10:23 AM
Replies: 2
Views: 372
Posted By ZestyMozzarella
Being familiar with VNC or TeamViewer, I know in...

Being familiar with VNC or TeamViewer, I know in a thinclient sense that you can definitely login to the same computer to view the instance at the same time and both have a separate mouse control...
Forum: LIVE PLC Questions And Answers December 5th, 2019, 09:59 AM
Replies: 1
Views: 279
Posted By ZestyMozzarella
I'm familiar with the DAS Server and newer IO...

I'm familiar with the DAS Server and newer IO Interfaces of Wonderware but uncertain about the toolkit. It would appear to be sort of like Kepware and other IO development software's that allow you...
Forum: LIVE PLC Questions And Answers December 3rd, 2019, 05:40 PM
Replies: 7
Views: 646
Posted By ZestyMozzarella
As a closing follow up for others, there were no...

As a closing follow up for others, there were no memory overlaps or extended data types interfering. The momentary blinking as the program grew in scan time as Gary eluded to seems to have been the...
Forum: LIVE PLC Questions And Answers December 1st, 2019, 12:45 PM
Replies: 7
Views: 646
Posted By ZestyMozzarella
Thanks for the advice. I'll be back at it...

Thanks for the advice. I'll be back at it tomorrow morning. I'll run through the variable list to see if there are any doubles or expanded memory areas that are potentially causes for an overwrite...
Forum: LIVE PLC Questions And Answers November 28th, 2019, 01:23 PM
Replies: 7
Views: 646
Posted By ZestyMozzarella
RX3I Ghost Rung Occurence - Possible Corruption?

Hi everyone, had an odd occurence happen and wondering if its ever happened to anyone else in their field. Programming a GE RX3I with Quickpanel+. There is a stop button on the HMI tied to a...
Forum: LIVE PLC Questions And Answers November 26th, 2019, 04:26 PM
Replies: 10
Views: 393
Posted By ZestyMozzarella
They are senseless vector drives, Schneider...

They are senseless vector drives, Schneider Avaltar 212 HVAC.
Forum: LIVE PLC Questions And Answers November 26th, 2019, 02:44 PM
Replies: 10
Views: 393
Posted By ZestyMozzarella
Modifying an existing system. Beyond setting a...

Modifying an existing system. Beyond setting a drive bias of operating at say 70% it's RPM capacity, there is no control on it. As you imply, it simply continues to ramp until it hits maximum RPM...
Forum: LIVE PLC Questions And Answers November 26th, 2019, 09:57 AM
Replies: 10
Views: 393
Posted By ZestyMozzarella
Also for anyone that does come across this...

Also for anyone that does come across this article in the future, I found this nifty little PID tuning pocket guide that shares a plethora of PLC brands and seems very useful. Thought I would post...
Forum: LIVE PLC Questions And Answers November 26th, 2019, 09:43 AM
Replies: 10
Views: 393
Posted By ZestyMozzarella
I have seen a couple applications with GE/LE...

I have seen a couple applications with GE/LE comparisons but I agree that an ON/OFF sounds like a terrible idea which lead me here. The RPM range of the motor is standard industrial 0-1760 RPM. The...
Forum: LIVE PLC Questions And Answers November 25th, 2019, 04:44 PM
Replies: 10
Views: 393
Posted By ZestyMozzarella
GE RX3I Motor Speed Control

Quick question on my first from scratch program needing to control the speed of a motor via controlled input to a motor drive; is it more applicable to use a GE/LE Comparison Scale to turn the motor...
Forum: LIVE PLC Questions And Answers September 6th, 2019, 05:40 PM
Replies: 14
Views: 747
Posted By ZestyMozzarella
Cannot two S7 1200's just Modbus TCP/IP configure...

Cannot two S7 1200's just Modbus TCP/IP configure to talk information back and forth?
Forum: LIVE PLC Questions And Answers September 6th, 2019, 05:35 PM
Replies: 3
Views: 517
Posted By ZestyMozzarella
Fairly certain we're allowed to share these and...

Fairly certain we're allowed to share these and they're legacy at this point, someone please update me if not so, but here is the Serial Communications manual for the 90-30 Series PLCs. In it, you...
Forum: LIVE PLC Questions And Answers September 6th, 2019, 05:06 PM
Replies: 14
Views: 769
Posted By ZestyMozzarella
I do not believe the 90-30's had a way like the...

I do not believe the 90-30's had a way like the newer Rx3i's to flash upgrade via USB. I believe upgrades were done via "kits" that you had to order from a distributor and I believe it was actually...
Forum: LIVE PLC Questions And Answers September 3rd, 2019, 02:00 PM
Replies: 3
Views: 526
Posted By ZestyMozzarella
Thanks everyone. These are all fresh...

Thanks everyone.

These are all fresh variable locations separated with plenty of room. I assured myself before allocating them, that they're not part of any other locations or scripting. I...
Forum: LIVE PLC Questions And Answers August 30th, 2019, 09:50 AM
Replies: 3
Views: 526
Posted By ZestyMozzarella
GE Rx3i Register Issue

Hi everyone, not sure if anyone else has ever witnessed this in a GE Rx3i register value, but I got a floating point value being fed into a register written there from a Wonderware HMI. Every now...
Forum: LIVE PLC Questions And Answers June 8th, 2019, 12:58 PM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
Not any difference whatsoever on my end. I still...

Not any difference whatsoever on my end. I still get the same two guys every time I call whether that is my area driven or not. I asked the guy I deal with and like having a lot and he said nothing...
Forum: LIVE PLC Questions And Answers June 8th, 2019, 01:53 AM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
A note for future viewers, I had to add a 5...

A note for future viewers, I had to add a 5 second delay to the beginning of my close operation. Apparently trying to initiate a close from open too fast does not allow all my open conditions to...
Forum: LIVE PLC Questions And Answers June 7th, 2019, 05:48 PM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
SUCCESS!!! It works! So here is what I had to...

SUCCESS!!! It works! So here is what I had to do:

1. I was not making full use of LAN status bits at the beginning of each sequence.

2. My close instruction was missing a single one-shot...
Forum: LIVE PLC Questions And Answers June 7th, 2019, 10:50 AM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
Also, do not see a way to attach a zip. I...

Also, do not see a way to attach a zip. I upgraded with a $20 donation that I think allows it? I don't see my account updated though, perhaps it takes a little bit. I'll keep an eye and post the...
Forum: LIVE PLC Questions And Answers June 7th, 2019, 10:49 AM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
Yes, I can one to two channels to work, multiples...

Yes, I can one to two channels to work, multiples start failing beyond that. I can read and write in a sequence of one shots successfully on a single channel all day long no problem. When multiple...
Forum: LIVE PLC Questions And Answers June 6th, 2019, 04:30 PM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
Yes, it was stating only one comm_req per channel...

Yes, it was stating only one comm_req per channel can be pending at one time, so given that, I'm assuming I can have one Comm_req processing in each of the six channels, but not more than one in a...
Forum: LIVE PLC Questions And Answers June 6th, 2019, 03:04 PM
Replies: 8
Views: 791
Posted By ZestyMozzarella
If the emitter is far enough away from the...

If the emitter is far enough away from the sensor, I would consider a concentrated air hose to keep contaminates from building up on the sensor, otherwise a backup is possible, but expensive. At...
Forum: LIVE PLC Questions And Answers June 6th, 2019, 02:23 PM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
And yes, reading and writing, but one comm_req at...

And yes, reading and writing, but one comm_req at a time waiting to go to next between each command (waits for CRS good response to continue). The structure is much like what was advised in the...
Forum: LIVE PLC Questions And Answers June 6th, 2019, 02:22 PM
Replies: 16
Views: 1,495
Posted By ZestyMozzarella
Multiple channels should be able to talk and...

Multiple channels should be able to talk and operate individually at the same time right? That is what I believe I read, up to sixteen channels at once, but each channel must be sequenced properly...
Showing results 1 to 25 of 28

 
Forum Jump

All times are GMT -5. The time now is 09:52 PM.


.