Search: Posts Made By: sjohnson
Forum: LIVE PLC Questions And Answers Yesterday, 12:23 PM
Replies: 11
Views: 253
Posted By sjohnson
Gregg I just did what you are looking for last...

Gregg I just did what you are looking for last week. It is kind of a hidden feature that you would really think of as a feature. Use the Screen saver and auto log out so if one walks away it will log...
Forum: LIVE PLC Questions And Answers April 12th, 2018, 09:54 AM
Replies: 36
Views: 1,620
Posted By sjohnson
Maybe a bent pin or possible that you had the...

Maybe a bent pin or possible that you had the arrow in the base 180 out and it went together but wasn't correct. I was able to put one together without trouble by accident once. but glad to hear it...
Forum: LIVE PLC Questions And Answers April 9th, 2018, 09:18 AM
Replies: 5
Views: 956
Posted By sjohnson
Welcome to the world of automation.. Things...

Welcome to the world of automation.. Things aren't always just a click away or black and white.. Probably pay a bit more here but it is a add to cart.. You will probably find it a bit cheaper from a...
Forum: LIVE PLC Questions And Answers April 9th, 2018, 07:10 AM
Replies: 5
Views: 956
Posted By sjohnson
Most Big Name Brand company's relay on...

Most Big Name Brand company's relay on distributors to do the dirty work for them at the bottom of the page is where you find the locator...

https://exorint.com/locations/
Forum: LIVE PLC Questions And Answers April 3rd, 2018, 09:40 AM
Replies: 36
Views: 1,620
Posted By sjohnson
Maybe only thing I can see is double check the...

Maybe only thing I can see is double check the jumper settings with the module properties to make sure they are correct. Double check to make sure you have the correct Chassis and power supply as...
Forum: LIVE PLC Questions And Answers April 3rd, 2018, 07:11 AM
Replies: 36
Views: 1,620
Posted By sjohnson
Does Either of the Remote I/O have all Status LED...

Does Either of the Remote I/O have all Status LED Green? or is both Have a yellow Fault?
Forum: LIVE PLC Questions And Answers April 3rd, 2018, 06:19 AM
Replies: 36
Views: 1,620
Posted By sjohnson
Steve I am using a Tripp-Lite CPXX URT Chip with...

Steve I am using a Tripp-Lite CPXX URT Chip with good results windows 7 and 10. I would stay away from the Prolific Chip ones as to the Chinese clones circulating with driver issues. . A Good CPXX...
Forum: LIVE PLC Questions And Answers March 23rd, 2018, 07:43 AM
Replies: 36
Views: 1,620
Posted By sjohnson
You are on the right track as far as setting up...

You are on the right track as far as setting up the Genius in the BEM331 and GBI001 as the data has to match both units in your Proficy machine hardware. You need to download your configuration to...
Forum: LIVE PLC Questions And Answers February 22nd, 2018, 06:58 AM
Replies: 7
Views: 307
Posted By sjohnson
It was in GFK-1541 : "TASK: For the Series...

It was in GFK-1541 :
"TASK: For the Series 90-30 CPU364, this must always be set to 21 decimal (0015H). For the
Series 90-30 Ethernet Interface and the Series 90-70 Ethernet Interface (Type2), this...
Forum: LIVE PLC Questions And Answers February 22nd, 2018, 06:50 AM
Replies: 7
Views: 307
Posted By sjohnson
Close Channel Remember the Task is for the CPE305...

Close Channel Remember the Task is for the CPE305 and may not work for the 364

NCCON CHNNL_OPEN_SUCSS_BIT,G,%M00103; H_WIRE; H_WIRE; H_WIRE; ONDTR_TENTHS R09242,G,%R09242 ** 100...
Forum: LIVE PLC Questions And Answers February 22nd, 2018, 06:47 AM
Replies: 7
Views: 307
Posted By sjohnson
The 364 in listed in GFK-1541 and I don't see...

The 364 in listed in GFK-1541 and I don't see anywhere that there is restriction. You might want to make sure you have the latest firmware as it looks like 10.75 or so. There are many ways to do the...
Forum: LIVE PLC Questions And Answers January 22nd, 2018, 06:45 AM
Replies: 2
Views: 324
Posted By sjohnson
I asked Ge about running on windows server and...

I asked Ge about running on windows server and they said no. But wasn't till after trying it on 2003 and it crashed the server. They said You can however build a Virtual windows or such inside the...
Forum: LIVE PLC Questions And Answers December 28th, 2017, 12:27 PM
Replies: 5
Views: 447
Posted By sjohnson
Lengths make a difference as standard Ethernet...

Lengths make a difference as standard Ethernet would You could use a repeater or Switch but would not do it in a high speed servo type setting.. Being a HMI probably not an issue but well worth the...
Forum: LIVE PLC Questions And Answers December 28th, 2017, 05:20 AM
Replies: 7
Views: 895
Posted By sjohnson
Not sure if it is Related but worth checking....

Not sure if it is Related but worth checking. Every time I smell a fire on a new panel it is usually caused by someone wiring 120Vac to a 24VDC circuit or 24VDC to a 24VAC circuit. 9 out of 10...
Forum: LIVE PLC Questions And Answers December 21st, 2017, 12:46 PM
Replies: 5
Views: 446
Posted By sjohnson
Steve thanks for the reply, The biggest question...

Steve thanks for the reply, The biggest question I had was it looks like the MODBUS TCP RW instruction that is used now for the Versamax UDR140 with the UEM001 that you no longer use the open channel...
Forum: LIVE PLC Questions And Answers December 21st, 2017, 08:27 AM
Replies: 5
Views: 446
Posted By sjohnson
Thanks for the Replys, I have been looking at...

Thanks for the Replys, I have been looking at those pages of the GFK-1645 pretty vague but was hoping for an different manual like there was for coms for the 9030 ect. there was a couple extra...
Forum: LIVE PLC Questions And Answers December 20th, 2017, 09:44 AM
Replies: 5
Views: 446
Posted By sjohnson
GE FANUC VersaMax IC200UEM001

Good Day and Merry Christmas.. I have a IC200UDR140 Fitted with a IC200UEM001 Ethernet Module. I am looking at setting up Modbus/TCP communications. I have set up the Ethernet Module with the Modbus...
Forum: LIVE PLC Questions And Answers May 25th, 2017, 04:04 PM
Replies: 25
Views: 3,678
Posted By sjohnson
Every application is different and one needs to...

Every application is different and one needs to adjust accordingly. I have one application that monitors the status word of the comms and when it times out or drops or whatever the reason when it...
Forum: LIVE PLC Questions And Answers April 9th, 2017, 07:05 PM
Replies: 23
Views: 3,614
Posted By sjohnson
What is the model you are using ?

What is the model you are using ?
Forum: LIVE PLC Questions And Answers April 9th, 2017, 05:59 PM
Replies: 23
Views: 3,614
Posted By sjohnson
Did you try the default password? 111111

Did you try the default password? 111111
Forum: LIVE PLC Questions And Answers April 5th, 2017, 01:31 PM
Replies: 49
Views: 2,244
Posted By sjohnson
I know on my CMM321's some have the Stat blinking...

I know on my CMM321's some have the Stat blinking some do not. I know it blinks when a power cycle or after starting when project download. But it soon goes out on a few of them. It never prevented...
Forum: LIVE PLC Questions And Answers April 5th, 2017, 11:05 AM
Replies: 49
Views: 2,244
Posted By sjohnson
Pages 2-4 and 2-5 of GFK-2382A STAT LED...

Pages 2-4 and 2-5 of GFK-2382A

STAT LED Operation
The STAT LED indicates the condition of the Ethernet interface in normal operational mode. If
the STAT LED is off, an event has been entered...
Forum: LIVE PLC Questions And Answers April 5th, 2017, 08:39 AM
Replies: 49
Views: 2,244
Posted By sjohnson
Thatís probably the biggest reason I started the...

Thatís probably the biggest reason I started the Upgrading to the RX3i is the mature and discontinued items were twice if not 3 times the cost of the New. Being a first time buyer you might qualify...
Forum: LIVE PLC Questions And Answers April 5th, 2017, 06:45 AM
Replies: 49
Views: 2,244
Posted By sjohnson
Those errors and warnings are configurable in...

Those errors and warnings are configurable in Your Machine edition Under Options then Controller and General. The coil conflict and type mismatch can be set to warn or not warn. My findings are if it...
Forum: LIVE PLC Questions And Answers March 10th, 2017, 12:31 PM
Replies: 1
Views: 615
Posted By sjohnson
Page 338 of GFK-1645L shows the pinout of DB9 to...

Page 338 of GFK-1645L shows the pinout of DB9 to rj-45 RS-232 you could use a cable . Or could try using program Advanced IP Scanner and use crossover Ethernet or a switch and scan and get the ip...