Forum: LIVE PLC Questions And Answers October 24th, 2012, 07:57 AM
Replies: 0
Views: 1,385
Posted By burbrink
RSLinx DDE Exception

I'm getting an RSLinx error in the Windows event log.

"A DDE Client has caused an exception to occur in the DDE substem"

When we get this error, all RSLinx unsolicited message handling stops...
Forum: LIVE PLC Questions And Answers July 25th, 2012, 07:38 AM
Replies: 14
Views: 4,400
Posted By burbrink
Upgraded RSLinx from 2.58 to 2.59 ... problem...

Upgraded RSLinx from 2.58 to 2.59 ... problem seems resolved.
Forum: LIVE PLC Questions And Answers February 8th, 2012, 04:24 PM
Replies: 0
Views: 761
Posted By burbrink
RSLinx message receipt using Allen Bradley Gateway

Does anyone have experience receiving unsolicited messages using RSLinx through an Allen Bradley gateway? We're trying to send message over DH+ (1756 DHRIO), backplane to 1776-ENBT module to RSLinx....
Forum: LIVE PLC Questions And Answers January 23rd, 2012, 01:57 PM
Replies: 5
Views: 5,414
Posted By burbrink
RSLinx Classic 2.59 - Release Notes

Does anyone know what issues have been addressed (ie release notes) for RSLinx 2.59 Classic?

Thanks,
Steve
Forum: LIVE PLC Questions And Answers January 13th, 2012, 03:21 PM
Replies: 14
Views: 4,400
Posted By burbrink
I seem to have baffled everyone?

I seem to have baffled everyone?
Forum: LIVE PLC Questions And Answers January 5th, 2012, 04:08 PM
Replies: 14
Views: 4,400
Posted By burbrink
With the way we implement our product, we...

With the way we implement our product, we actually need to increase the parameters mentioned in the pdf article. We've found that under heavy loads, the defaults don't work and cause delays in...
Forum: LIVE PLC Questions And Answers January 5th, 2012, 11:57 AM
Replies: 14
Views: 4,400
Posted By burbrink
Sorry for posting the first reply .. see more...

Sorry for posting the first reply .. see more questions.
1. Please describe in detail what you consider a "lockup" of RSLinx Classic.
Our product uses RSLinx as an OPC server. It receives...
Forum: LIVE PLC Questions And Answers January 5th, 2012, 11:49 AM
Replies: 14
Views: 4,400
Posted By burbrink
Remvoed .. see below

Remvoed .. see below
Forum: LIVE PLC Questions And Answers January 5th, 2012, 08:50 AM
Replies: 14
Views: 4,400
Posted By burbrink
Running as a service - this is a production...

Running as a service - this is a production server which isn't actively managed - you turn it on and it works.
Forum: LIVE PLC Questions And Answers January 4th, 2012, 02:10 PM
Replies: 14
Views: 4,400
Posted By burbrink
We're using an Ethernet interface.... Why do you...

We're using an Ethernet interface.... Why do you make the "serial port" comment?
Forum: LIVE PLC Questions And Answers January 4th, 2012, 02:06 PM
Replies: 14
Views: 4,400
Posted By burbrink
RSLinx 2.58 Hanging - Win2008 R2

We're running RSLinx 2.58 on Win2008 R2.

We've had some issues with it "locking up". Only way to getting it running is to use Task Manager and Kill the process.

RSLinx is configured to...
Forum: LIVE PLC Questions And Answers November 9th, 2011, 10:27 AM
Replies: 6
Views: 30,518
Posted By burbrink
Thank you... The thread...

Thank you... The thread http://www.plctalk.net/qanda/showthr...t=rslinx+edits (http://www.plctalk.net/qanda/showthread.php?t=66764&highlight=rslinx+edits) provided a solution!
Forum: LIVE PLC Questions And Answers November 9th, 2011, 10:10 AM
Replies: 6
Views: 30,518
Posted By burbrink
Not much of the older software (Logix 500) is...

Not much of the older software (Logix 500) is officially compatible with Win 7 - 64. It works, not reliabibly.

The configuration is a 5/05 over ethernet, using RSLinx 2.58.
Forum: LIVE PLC Questions And Answers November 9th, 2011, 09:50 AM
Replies: 6
Views: 30,518
Posted By burbrink
RSLogix 500 (Version 8.4.XX) & Windows 7 64 Bit

Using Logix 500 (Vers 8.4.XX & Win 7 - 64-Bit) I seem to be having a lot of trouble when performing online editing.

About 50% of the time when I go to assemble edits, Logix simply Fails and...
Forum: LIVE PLC Questions And Answers May 31st, 2007, 12:43 PM
Replies: 6
Views: 2,777
Posted By burbrink
Driver support ... If it's an "Out of the Box"...

Driver support ... If it's an "Out of the Box" Dell server with drivers, would you see driver issues with it?

I have a small C++ application, that can be compiled for X64 architecture and the...
Forum: LIVE PLC Questions And Answers May 31st, 2007, 09:12 AM
Replies: 6
Views: 2,777
Posted By burbrink
So RSLinx 2.5X will work ok with 2003 Server X64?...

So RSLinx 2.5X will work ok with 2003 Server X64? I have a very high speed application where I am receiving unsolicited messages (10-15 a second) that I am considering using all X64 components (SQL...
Forum: LIVE PLC Questions And Answers May 30th, 2007, 11:21 PM
Replies: 6
Views: 2,777
Posted By burbrink
RSLinx and Windows 2003 Server X64

Does anybody have experience with Windows 2003 Server x64 Architecture and RSLinx 2.5?