Forum: LIVE PLC Questions And Answers January 10th, 2019, 03:36 AM
Replies: 20
Views: 1,237
Posted By controlconcepts
Wow I'm all over the thread. This brings up some...

Wow I'm all over the thread. This brings up some really interesting thoughts and questions. Just bought a new house and about to do the same thing. My biggest issue it's just that of resale or God...
Forum: LIVE PLC Questions And Answers January 7th, 2019, 12:33 PM
Replies: 36
Views: 1,502
Posted By controlconcepts
Amen to that. Just bought a new house and this...

Amen to that.
Just bought a new house and this is a must.
"only automation will be done with a PLC and me pushing a HMI button" On a air gapped network.
It's so tempting with all the great fancy...
Forum: LIVE PLC Questions And Answers December 25th, 2018, 03:46 PM
Replies: 24
Views: 1,524
Posted By controlconcepts
One thing I also try with serial comms is to...

One thing I also try with serial comms is to verify the settings through typing mode into a command prompt. This will also show if the com Port is in use. If it is open it will not show the com port....
Forum: LIVE PLC Questions And Answers July 7th, 2018, 10:28 PM
Replies: 27
Views: 2,370
Posted By controlconcepts
I had just a thought about the strain on the...

I had just a thought about the strain on the communications and the amount of messages.

You said that you are reading 100 integers from each micrologix, 20 integers are status, alarms, counters...
Forum: LIVE PLC Questions And Answers May 28th, 2018, 04:50 AM
Replies: 3
Views: 499
Posted By controlconcepts
To find G file length I/O Configuration ...

To find G file length
I/O Configuration
Advanced Config on bottom left after module selected.
Not familiar with this module so can't give you a value to plug in.
Forum: LIVE PLC Questions And Answers May 28th, 2018, 04:11 AM
Replies: 7
Views: 678
Posted By controlconcepts
Look up flip flop.

Look up flip flop.
Forum: LIVE PLC Questions And Answers March 9th, 2018, 02:35 AM
Replies: 7
Views: 3,207
Posted By controlconcepts
Have had the same thing happen as well. All I did...

Have had the same thing happen as well. All I did was logged in to a different class even without a password just by clicking OK with a empty password would then allow online editing. Hope this helps.
Forum: LIVE PLC Questions And Answers December 29th, 2017, 03:49 PM
Replies: 43
Views: 3,392
Posted By controlconcepts
A bit expensive but I would go the serial to...

A bit expensive but I would go the serial to Ethernet port server route. I have never had any issues with any serial device. It is also so great that I can drop the port server in a control panel and...
Forum: LIVE PLC Questions And Answers December 29th, 2017, 12:41 AM
Replies: 6
Views: 871
Posted By controlconcepts
In situations like this where the wires are...

In situations like this where the wires are already labled and your dealing with a rusty mess what has been a life saver is clear heat shrink to put over the individual wire numbers. I've had it...
Forum: LIVE PLC Questions And Answers October 27th, 2017, 03:39 PM
Replies: 2
Views: 554
Posted By controlconcepts
Yes I have done this recently. As you have...

Yes I have done this recently. As you have assumed it Is very similar to the PLC 5 block transfers. The only difference is using M data files for BRW & BTR. I used the 1747-SN RIO manual which has...
Forum: LIVE PLC Questions And Answers September 15th, 2017, 04:43 PM
Replies: 2
Views: 525
Posted By controlconcepts
Wow!! Thank you so very much Contr_Conn. I was...

Wow!! Thank you so very much Contr_Conn. I was just taking a shot at it on here not thinking I would not get anything as to how old it was. All I really need is the module setup as to BTW and BTR. ...
Forum: LIVE PLC Questions And Answers September 14th, 2017, 06:06 PM
Replies: 2
Views: 525
Posted By controlconcepts
AB 1771-QRC Rev A Series C Manual

Hello All,
I have a 1771-QRC Rev A Series C Module that I need manual for.
On the card it says (See Users Manual Ref # 1771-6.5.20)

I have searched and searched and the only results I found...
Forum: LIVE PLC Questions And Answers April 11th, 2017, 04:15 PM
Replies: 10
Views: 1,592
Posted By controlconcepts
@Aabeck Not sure if it will install on a tablet...

@Aabeck
Not sure if it will install on a tablet but if it is a full windows version it would be worth a try. I have used serial port servers like systech or digi with advancedhmi and many other...
Forum: LIVE PLC Questions And Answers April 5th, 2017, 05:55 PM
Replies: 32
Views: 2,494
Posted By controlconcepts
Not sure this could be an option as you have said...

Not sure this could be an option as you have said a new sensor is not an option. What I have done for removable apparatus that must be connected for opperation but also removable for maintenance is...
Forum: LIVE PLC Questions And Answers February 24th, 2017, 01:38 PM
Replies: 56
Views: 12,826
Posted By controlconcepts
One of the ones that always sticks out in my...

One of the ones that always sticks out in my head.
Work scope : 480V feeder junction boxes to 4 heaters about 5 or 6 of them total all # 14 thhn brown orange, yellow.
Forman
" Jason go...
Forum: LIVE PLC Questions And Answers December 30th, 2016, 12:06 AM
Replies: 7
Views: 1,210
Posted By controlconcepts
Thank you all for the prompt responses. That is...

Thank you all for the prompt responses. That is what I had figured. But never hurt's to ask.
Forum: LIVE PLC Questions And Answers December 27th, 2016, 06:17 PM
Replies: 7
Views: 1,210
Posted By controlconcepts
Thanks, Micky. That's what I thought. Dose...

Thanks, Micky. That's what I thought.

Dose that mean swapping out to a DH+ card is out of the question or just for the DF1 port?
Thanks
Forum: LIVE PLC Questions And Answers December 27th, 2016, 05:41 PM
Replies: 7
Views: 1,210
Posted By controlconcepts
One other thing I was wondering is the DeviceNet...

One other thing I was wondering is the DeviceNet port the only way for the PV to communicate to a PLC or can you use the DF1 port to connect to the PLc?
Forum: LIVE PLC Questions And Answers December 27th, 2016, 05:26 PM
Replies: 7
Views: 1,210
Posted By controlconcepts
Panel view 1000 Devicenet to DH+ Change

I have a PV 1000 T10C10 Ser B That has from the factory the DeviceNet communication card installed. I am wondering if it is possible to change the Comm card out to a DH+ one. I am think the firmware...
Forum: LIVE PLC Questions And Answers March 22nd, 2016, 01:13 AM
Replies: 17
Views: 2,420
Posted By controlconcepts
Sorry for the confusion Mickey. I thought I had...

Sorry for the confusion Mickey. I thought I had posted this earlier. It is a 1771 ifm fast millivolt series B. I must have fat fingered it during the evil copy and paste.
Forum: LIVE PLC Questions And Answers March 20th, 2016, 06:57 AM
Replies: 17
Views: 2,420
Posted By controlconcepts
Great leadMicky

I have now tried.

Fresh .RSP with only new files.
Test AS per Micky's link

1771-IFF A
Fast Analog Input, 16 single-ended or 8 differential channels
1771-IFF B
...
Forum: LIVE PLC Questions And Answers March 18th, 2016, 08:46 PM
Replies: 17
Views: 2,420
Posted By controlconcepts
Thank you very much micky. I tried your...

Thank you very much micky. I tried your suggestion with the output file would have never thought to look at that, really smart and makes complete sense,
thanks. It is in a test rack that had...
Forum: LIVE PLC Questions And Answers March 17th, 2016, 07:11 AM
Replies: 17
Views: 2,420
Posted By controlconcepts
Dropped the Ball on this .RSP Finally

Guess I may have Not been proper in one of my post's. Since then I have had dead ears Here. I Have had a lot of family health and personal struggles lately. Now I am back if anyone would like to...
Forum: LIVE PLC Questions And Answers February 24th, 2016, 11:56 PM
Replies: 17
Views: 2,420
Posted By controlconcepts
So finally got logged in... I should not post...

So finally got logged in... I should not post until I have the file on local disk..

Module # AB 1771-IFM Series B
Part # 96069682
only jumpers ( viewed by on site tech)

Run/Cal [ Run ]
JP1 ...
Forum: LIVE PLC Questions And Answers February 22nd, 2016, 02:42 AM
Replies: 17
Views: 2,420
Posted By controlconcepts
Just got logged in to site will post .RSP .. ...

Just got logged in to site will post .RSP ..
Oddly I tried one of the manuals trouble shooting recommendations , go from RUN-Prog-Run and let module power up then do a read.
Result is BTR EN...