Forum: LIVE PLC Questions And Answers November 19th, 2015, 10:35 AM
Replies: 8
Views: 1,090
Posted By krakenfan69
Thanks to all who have replied. (Doug -P, I...

Thanks to all who have replied. (Doug -P, I have that manual already but never saw a reference to using just one bit) It appears to indeed be a pulse for a flasher. Albeit a strange one.
...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 06:26 PM
Replies: 12
Views: 1,116
Posted By krakenfan69
Also have you tried to right click on the add-on...

Also have you tried to right click on the add-on and select view logic to see all the lad files behind the Add on to see whats actually happening to the timer? If it lets you this often is an easy...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 04:30 PM
Replies: 8
Views: 1,090
Posted By krakenfan69
PLC2 Timer question

HI again guys,

Still converting my PLC2 project and ran into an issue with a timer. I get that the PLC2 timers Start at the 030 address and that the bit 15 is the Done bit and bit 17 is the...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 02:48 PM
Replies: 10
Views: 897
Posted By krakenfan69
Mad respect to Rootboy for his help. Thanks to...

Mad respect to Rootboy for his help. Thanks to all the other posters as well. Rootboy suggested installing NotePad++ to help find and replace formatting errors. Yeah, do that. it's wicked. I...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 02:22 PM
Replies: 10
Views: 897
Posted By krakenfan69
I'm seeing that i should have turned off some...

I'm seeing that i should have turned off some options like printing the cross reference next to each I/O Point as well. Less clutter.

EDIT. Yeah much less busy with out the XRef printing out.
...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 01:45 PM
Replies: 10
Views: 897
Posted By krakenfan69
Thanks Rootboy, What I figured out was I...

Thanks Rootboy,

What I figured out was I was getting the DOS Write Error because I had left the default printer port to LPT1 and not changed that to a file name logic.txt for instance as...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 01:33 PM
Replies: 10
Views: 897
Posted By krakenfan69
When I try to print from the software (PLC-2...

When I try to print from the software (PLC-2 Ladder Logistics is all I see for a name) it throws up a DOS Write error. Its running on an old Win98 machine. The Dos window on this old beast is not...
Forum: LIVE PLC Questions And Answers November 18th, 2015, 11:37 AM
Replies: 10
Views: 897
Posted By krakenfan69
Printing out a PLC2 LAD file

Hi guys,

Upgrading a PLC2 to CompactLogix. I have a VERY old laptop running the PLC2 software. How can I get a hard copy printed out? No chance I can hook this to our networked printer. ...
Forum: LIVE PLC Questions And Answers March 27th, 2015, 03:57 PM
Replies: 1
Views: 527
Posted By krakenfan69
Beijer Trend only allowing 48 hours of history???

I guys. I have a Beijer T12 panel that was developed by someone else. The trending is only allowing the last 48 hours to show. All the curves in the panel are updated every 60 seconds and the...
Forum: LIVE PLC Questions And Answers November 26th, 2014, 12:40 PM
Replies: 3
Views: 1,112
Posted By krakenfan69
Sorry. No experience with Wnderware (clearly)...

Sorry. No experience with Wnderware (clearly) and misunderstood what the customer said. Thanks for the heads up guys.

Kraken Fan #69
Forum: LIVE PLC Questions And Answers November 26th, 2014, 12:36 PM
Replies: 48
Views: 7,108
Posted By krakenfan69
If the PLC is connected to an HMI can you not...

If the PLC is connected to an HMI can you not open that program and see what communication protocol it is using and then disconnect the HMI and connect to t he PLC to do an upload , set an IP address...
Forum: LIVE PLC Questions And Answers November 26th, 2014, 12:11 PM
Replies: 3
Views: 1,112
Posted By krakenfan69
Programming Schneider Momentum PLC with RSLogix5000?

I have a customer that would like to move away from Wonderware to RSlogix5000. They currently have Schneider TSX PLCs at their location and would like to minimize the upgrade by being able to use...
Forum: LIVE PLC Questions And Answers November 25th, 2014, 04:54 PM
Replies: 5
Views: 1,813
Posted By krakenfan69
I don't tend to like that kind of code and have...

I don't tend to like that kind of code and have actively removed it from more than one program at operations request. It can tend to be an issue when you are trouble shooting and want to see...
Forum: LIVE PLC Questions And Answers November 25th, 2014, 04:39 PM
Replies: 11
Views: 2,227
Posted By krakenfan69
UPDATE: I got it working using VANs method. ...

UPDATE: I got it working using VANs method. Took me a minute or two (ten) to get the data table right Then I tossed it in a test rack and had at it. A little more tweaking and bingo! Thanks for...
Forum: LIVE PLC Questions And Answers November 25th, 2014, 01:10 PM
Replies: 11
Views: 2,227
Posted By krakenfan69
Yeah I know. I was working on my reply to an...

Yeah I know. I was working on my reply to an earlier post without seeing yours. ;)

Kraken Fan #69
Forum: LIVE PLC Questions And Answers November 25th, 2014, 12:11 PM
Replies: 11
Views: 2,227
Posted By krakenfan69
Thanks for the replies so far guys. I am trying...

Thanks for the replies so far guys. I am trying to keep away form the excel solutions as this will be driving SD's I am concerned about the excel sheet getting closed and then I am not populating...
Forum: LIVE PLC Questions And Answers November 24th, 2014, 06:11 PM
Replies: 11
Views: 2,227
Posted By krakenfan69
Cross referencing 2 variables to a chart in 5000?

HI guys,


I have a project where I need to set a SD based off of 2 variables. Speed and Differential pressure. I have a table that has the speed setpoints down the left side and the diff...
Forum: LIVE PLC Questions And Answers August 24th, 2014, 12:53 PM
Replies: 1
Views: 542
Posted By krakenfan69
Panelview Plus 1000 Alarm Ack time issue

Hi Guys,
I tried searching but search parameters "Alarm and Ack" will get a sea of hits. :confused: I have a PVPlus 1000 with an Alarm List Display. The alarms all ring in great, show the time...
Forum: LIVE PLC Questions And Answers July 10th, 2014, 03:01 PM
Replies: 14
Views: 1,674
Posted By krakenfan69
Yeah I tried to explain setting up an...

Yeah I tried to explain setting up an Autoexec.bat and Config.sys to a guy the other day. May as well have been speaking Yiddish...

Kraken Fan #69
Forum: LIVE PLC Questions And Answers July 10th, 2014, 10:22 AM
Replies: 14
Views: 1,674
Posted By krakenfan69
Thanks I was able to open and view the file with...

Thanks I was able to open and view the file with that software and your help. You rock!
Funny Rockwell had no idea about that software.

Kraken Fan #69
Forum: LIVE PLC Questions And Answers July 9th, 2014, 04:45 PM
Replies: 14
Views: 1,674
Posted By krakenfan69
Wow. That was super fast!! Thanks for your...

Wow. That was super fast!! Thanks for your help. can I ask what software you used to open it up? Rockwell was just telling me there was no way it was an SLC 100/150 file as it did not have a...
Forum: LIVE PLC Questions And Answers July 9th, 2014, 04:13 PM
Replies: 14
Views: 1,674
Posted By krakenfan69
Looking for help with a PLC 100

I have been given an old file with the .100 extension that I was to use to create a new ML1400 program with but I have no way of opening the logic. Does anyone have software for that old dinosaur...
Forum: LIVE PLC Questions And Answers May 7th, 2014, 04:28 PM
Replies: 6
Views: 1,025
Posted By krakenfan69
Rockwell sent the issue to thier engineers and...

Rockwell sent the issue to thier engineers and they say there is an Edit Transaction Buffer (don't quote me on these names) that keeps track of online changes and something in there must have become...
Forum: LIVE PLC Questions And Answers May 7th, 2014, 02:45 PM
Replies: 6
Views: 1,025
Posted By krakenfan69
I had copied 7 rungs from an offline program and...

I had copied 7 rungs from an offline program and pasted them into the online program
and was accepting them one at a time. later it would do it if I edited one rung to add a branch around an alarm...
Forum: LIVE PLC Questions And Answers May 7th, 2014, 01:42 PM
Replies: 6
Views: 1,025
Posted By krakenfan69
PLC5 Buffer Overflow. Too Many Edits

So I was making some program changes to a PLC5/80 E-2000/Files Extended Rev F controller the other day and I got knocked offline with the following message. My memory usage is 55067 and free memory...