You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 0.10 seconds.
Search: Posts Made By: NetNathan
Forum: LIVE PLC Questions And Answers Yesterday, 05:18 PM
Replies: 2
Views: 293
Posted By NetNathan
The "gsdml" file is for recognizing and...

The "gsdml" file is for recognizing and configuring the Profinet devices use in the plc Logic.
A "Profinet Configurator" (like Profinet Commander) is for connecting to the device over Profinet and...
Forum: LIVE PLC Questions And Answers August 5th, 2020, 12:27 PM
Replies: 16
Views: 848
Posted By NetNathan
We commonly run 120 and 480 in same conduit, but...

We commonly run 120 and 480 in same conduit, but 600V rated wire.
We run a separate conduit with any 24 VDC, Analog signals, and Ethernet.
Forum: LIVE PLC Questions And Answers July 27th, 2020, 12:22 PM
Replies: 9
Views: 1,712
Posted By NetNathan
Sweet...

Sweet...
Forum: LIVE PLC Questions And Answers July 22nd, 2020, 05:14 PM
Replies: 10
Views: 1,857
Posted By NetNathan
I would worry big time on maintaining a...

I would worry big time on maintaining a connection to a PLC across the Internet. Lots of issues, dropped connection while downloading or editing could cause locked PLC or leave it in a dangerous...
Forum: LIVE PLC Questions And Answers July 19th, 2020, 05:33 PM
Replies: 21
Views: 1,730
Posted By NetNathan
Are you tracking more than 1 billet? Do the...

Are you tracking more than 1 billet?
Do the billets have S/N?
Trying to resolve a unique file name...
Forum: LIVE PLC Questions And Answers July 19th, 2020, 03:53 PM
Replies: 21
Views: 1,730
Posted By NetNathan
Can save more data in the file? Like every...

Can save more data in the file?
Like every hour rotate the file name, and inside are 60 readings every minute?
Forum: LIVE PLC Questions And Answers July 19th, 2020, 03:20 PM
Replies: 21
Views: 1,730
Posted By NetNathan
So you know have RunData 1 to RunData 3, for...

So you know have RunData 1 to RunData 3, for Date, Time and Data from tag.?
How often do you want to save the file?
Save on time change?
Save on data change?
Forum: LIVE PLC Questions And Answers July 17th, 2020, 09:58 PM
Replies: 21
Views: 1,730
Posted By NetNathan
See post 7 and 8, just remove or add what you do...

See post 7 and 8, just remove or add what you do not need...
http://www.plctalk.net/qanda/showthread.php?t=84472

Also..... read the help explanation of FileWriteFields in Intouch script box.
Forum: LIVE PLC Questions And Answers July 17th, 2020, 03:01 PM
Replies: 21
Views: 1,730
Posted By NetNathan
Check these links

Check these links
Forum: LIVE PLC Questions And Answers July 16th, 2020, 09:36 PM
Replies: 6
Views: 421
Posted By NetNathan
He wants a user to be be able to perform certain...

He wants a user to be be able to perform certain functions...
So he can still use IF $OperatorEntered = "USER" scripts on the button to allow functions based on User.
Forum: LIVE PLC Questions And Answers July 16th, 2020, 04:35 PM
Replies: 6
Views: 421
Posted By NetNathan
If just $OperatorEntered does not work, for sure...

If just $OperatorEntered does not work, for sure I believe $OperatorEntered = "USER Name" will work.
Forum: LIVE PLC Questions And Answers July 16th, 2020, 12:56 PM
Replies: 6
Views: 421
Posted By NetNathan
You can try an "On True" Condition script on...

You can try an "On True" Condition script on $OperatorEntered, or $OperatorEntered = "USER"

Script start...
IF $OperatorEntered = "USER" THEN
Forum: LIVE PLC Questions And Answers July 9th, 2020, 07:06 PM
Replies: 13
Views: 1,594
Posted By NetNathan
Have you talked to Anybus support? They will...

Have you talked to Anybus support? They will help if you show you are already trying to program it. just send them your config file and tell them your issue...
Forum: LIVE PLC Questions And Answers July 7th, 2020, 06:07 PM
Replies: 25
Views: 1,905
Posted By NetNathan
You might also try "Advanced CSV Converter". It...

You might also try "Advanced CSV Converter". It cross converts a lot of formats and supports command line operation.... also txt to csv.
Nice thing is if you buy, you get lifetime upgrades.
...
Forum: LIVE PLC Questions And Answers June 30th, 2020, 06:56 PM
Replies: 5
Views: 562
Posted By NetNathan
I would contact whoever you paid for the...

I would contact whoever you paid for the subscription.. It should have been transferred from GE to Emerson.
That is what happened to my contract.

Yes they are a little slow to respond and the...
Forum: LIVE PLC Questions And Answers June 26th, 2020, 02:53 PM
Replies: 20
Views: 1,634
Posted By NetNathan
NetSetMan Pro is my goto also. Great program and...

NetSetMan Pro is my goto also. Great program and you can change your computer IP in a flash. Worth the money.
Actually most can probably get by okay on the free version.... if you do not have more...
Forum: LIVE PLC Questions And Answers June 26th, 2020, 02:49 PM
Replies: 20
Views: 1,634
Posted By NetNathan
You can run Wonderware on LTSC? Intouch 2017 is...

You can run Wonderware on LTSC? Intouch 2017 is not compatible with LTSC (so it will not install), but it is compatible with LTSB.
This was a huge argument between me a WW on why they did not do...
Forum: LIVE PLC Questions And Answers June 26th, 2020, 02:00 PM
Replies: 29
Views: 2,017
Posted By NetNathan
Yes...going to screw up Master/Slave references...

Yes...going to screw up Master/Slave references for a lot of things, like Modbus, and a lot of other communication protocol references.
Forum: LIVE PLC Questions And Answers June 26th, 2020, 12:27 PM
Replies: 29
Views: 2,017
Posted By NetNathan
OOps....Cant use "Master" any more, must now be...

OOps....Cant use "Master" any more, must now be "Primary". "Master" is now considered racially biased...
Realtors in Texas and a few other states have been notified... It is Primary Bedroom and...
Forum: LIVE PLC Questions And Answers June 26th, 2020, 12:22 PM
Replies: 23
Views: 1,685
Posted By NetNathan
I run a Dell Precision M7730. Slightly spoiled...

I run a Dell Precision M7730. Slightly spoiled with power
You may also want to support VM drives
Can support up to 4 M2 drives, I am running 3 (1TB , 500GB, 500GB)
32GB of ram

This is my 3rd...
Forum: LIVE PLC Questions And Answers June 24th, 2020, 07:26 PM
Replies: 13
Views: 1,230
Posted By NetNathan
Lynda is very good and the price is not that...

Lynda is very good and the price is not that bad..
Plus with Lynda, you can take other courses also.
Forum: LIVE PLC Questions And Answers June 24th, 2020, 01:28 PM
Replies: 11
Views: 831
Posted By NetNathan
In AutoCad Electrical that is what it looks...

In AutoCad Electrical that is what it looks like..

You can get fancier and just ADD another 8 at 90 degrees. The you have a 4 blade fan.
Forum: LIVE PLC Questions And Answers June 24th, 2020, 11:07 AM
Replies: 11
Views: 831
Posted By NetNathan
I use a the number 8 at 90 degrees and put it in...

I use a the number 8 at 90 degrees and put it in a circle.
Forum: LIVE PLC Questions And Answers June 22nd, 2020, 04:05 PM
Replies: 40
Views: 1,995
Posted By NetNathan
Regrettably.... Wonderware tech support bailed on...

Regrettably.... Wonderware tech support bailed on it...

Nathan,
We can’t get the SMC to maximize consistency using server 2016.

We can sometimes get it to maximize and sometimes minimize but...
Forum: LIVE PLC Questions And Answers June 19th, 2020, 07:05 PM
Replies: 40
Views: 1,995
Posted By NetNathan
After about 12 emails back and forth on how it is...

After about 12 emails back and forth on how it is working and things to try..
It has now been passed from my local TS at Wonderware California (very knowledgeable guy who has helped me a bunch of...
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -4. The time now is 08:50 PM.


.