Forum: LIVE PLC Questions And Answers September 4th, 2017, 08:22 PM
Replies: 0
Views: 247
Posted By psychosunshine
PARKER-CTC Interact HMI Software - LRP File

I am taking over a CTC Interact project. All I have to start with is the LRP file. I do not know what version it was written in.

It was done about a year ago.

What I need to know, is what...
Forum: LIVE PLC Questions And Answers November 10th, 2016, 07:25 AM
Replies: 7
Views: 1,271
Posted By psychosunshine
Yeah, I thought about that. Although, it's a...

Yeah, I thought about that. Although, it's a printing press.
Forum: LIVE PLC Questions And Answers November 10th, 2016, 06:37 AM
Replies: 7
Views: 1,271
Posted By psychosunshine
Siemens S5 Programming Software

I have a customer that wants to upload a PLC program from a Siemens S5 PLC (115U CPU942).

It's a DB15 Female connector on the CPU.

What software and cable adapter would you guys recommend?
...
Forum: LIVE PLC Questions And Answers July 12th, 2016, 07:08 AM
Replies: 1
Views: 227
Posted By psychosunshine
Siemens S7-200 with VFDs Setup

I have 4 Siemens VFDs connected to an S7-200. Two of them are Micromaster and the other two are Micromaster 420 VFDs. How can I see in this PLC program how they are addressed? I am not that...
Forum: LIVE PLC Questions And Answers July 1st, 2016, 12:24 PM
Replies: 12
Views: 1,429
Posted By psychosunshine
Can anyone convert this project so that it can be...

Can anyone convert this project so that it can be downloaded into an HMI with ProSave?

ProSave will not open this project file?
Forum: LIVE PLC Questions And Answers June 17th, 2016, 04:51 PM
Replies: 12
Views: 1,429
Posted By psychosunshine
What I will need to do is to upload this project...

What I will need to do is to upload this project into a new (used) OP17 with ProSave (which uses a different file type) or I will have to use a new touchscreen HMI and convert or write from scratch...
Forum: LIVE PLC Questions And Answers June 17th, 2016, 04:47 PM
Replies: 12
Views: 1,429
Posted By psychosunshine
Yes! a PDF of the screens and the tag list if...

Yes! a PDF of the screens and the tag list if possible.

Is there a list of the tags and addresses that are attached to the F keys?
Forum: LIVE PLC Questions And Answers June 17th, 2016, 02:26 PM
Replies: 12
Views: 1,429
Posted By psychosunshine
Here is the project file... I have WinCC SP3...

Here is the project file...

I have WinCC SP3 upd3.

That's why I couldn't figure it out.
Forum: LIVE PLC Questions And Answers June 17th, 2016, 12:42 PM
Replies: 12
Views: 1,429
Posted By psychosunshine
I guess another option is to import this project...

I guess another option is to import this project into WinCC Flex. Does anyone know how to do that?
Forum: LIVE PLC Questions And Answers June 17th, 2016, 10:07 AM
Replies: 12
Views: 1,429
Posted By psychosunshine
Siemens ProTool Software for old OP17 Panel

Does anyone have the old ProTool software from Siemens?

I was wondering if someone could open a project for me or sell me the software. From Siemens it is obsolete.

I have a pdb file that I'd...
Forum: LIVE PLC Questions And Answers June 17th, 2016, 10:01 AM
Replies: 0
Views: 522
Posted By psychosunshine
Siemens ProTool Software for old OP17 Panel

Does anyone have the old ProTool software from Siemens?

I was wondering if someone could open a project for me or sell me the software. From Siemens it is obsolete.

I have a pdb file that I'd...
Forum: LIVE PLC Questions And Answers April 11th, 2016, 10:33 AM
Replies: 10
Views: 1,023
Posted By psychosunshine
I thought VM would be the answer. Now, I guess...

I thought VM would be the answer. Now, I guess I need to start learning how to use them.

Microsoft or VirtualBox?

I have Windows 7 64 bit
Forum: LIVE PLC Questions And Answers April 10th, 2016, 08:05 PM
Replies: 10
Views: 1,023
Posted By psychosunshine
Siemens Step 7 and RSLogix on same PC

My Windows 7 64 bit laptop has Step 7 on it.

I am going to do a Rockwell job tomorrow.

Do you know if there are any issues with installing RSLogix 500 or RSLogix 5000 on the same PC?

Thanks,...
Forum: LIVE PLC Questions And Answers September 4th, 2015, 11:47 AM
Replies: 0
Views: 403
Posted By psychosunshine
Hardware Config - You can only use IO devices in a PNIO syste, ERROR

Why am I getting this error?

I am trying to install a Turck module on this station.

This module is installed on several stations here with no issue.
Forum: LIVE PLC Questions And Answers August 18th, 2015, 01:51 PM
Replies: 3
Views: 1,048
Posted By psychosunshine
Step 7 Hardware Config Adding Module Error

I am trying to install an FVDO-P or an FVDO-P2 module into my hardware config in Siemens Step 7.

That is slot 5 of my module. But, when I try to install the module into that slot,...
Forum: LIVE PLC Questions And Answers August 13th, 2015, 07:27 AM
Replies: 2
Views: 792
Posted By psychosunshine
Step 7 5.5 SP3 Simatic Manager Zoom

Is there a way to zoom in, in Simatic Manager?

I have an extremely high resolution monitor (3200x1800) and it's hard to read.

I know that I can zoom in, in the ladder editor, and that helps a...
Forum: LIVE PLC Questions And Answers February 23rd, 2015, 06:09 AM
Replies: 4
Views: 737
Posted By psychosunshine
Siemens Step 7 Monitoring SF Indicator

Is there a way to monitor the error indicators of the PLC from Step 7 V5.5 SP3?
Forum: LIVE PLC Questions And Answers February 21st, 2015, 08:09 AM
Replies: 13
Views: 1,376
Posted By psychosunshine
What is the default IP address of a new S7-300?

What is the default IP address of a new S7-300?
Forum: LIVE PLC Questions And Answers February 20th, 2015, 06:54 AM
Replies: 13
Views: 1,376
Posted By psychosunshine
OK. The existing PLC is a 6ES7 315-2FJ14-0AB0 /...

OK. The existing PLC is a 6ES7 315-2FJ14-0AB0 / V3.2. And the new one is a 6ES7 317-2FK14-0AB0
Forum: LIVE PLC Questions And Answers February 19th, 2015, 05:23 PM
Replies: 13
Views: 1,376
Posted By psychosunshine
I was definitely planning on archiving the...

I was definitely planning on archiving the existing project first. I was also thinking of copying the online DBs to that offline project before archiving. Any thoughts on that?
Forum: LIVE PLC Questions And Answers February 19th, 2015, 01:48 PM
Replies: 13
Views: 1,376
Posted By psychosunshine
Upgrading a Siemens CPU315 to CPU319

I have never installed a brand new CPU before.

But, I need to take an existing project from a CPU315 and put it in a CPU319 because we are running out of memory in the 315.

We have...
Forum: LIVE PLC Questions And Answers January 26th, 2015, 06:14 AM
Replies: 15
Views: 1,859
Posted By psychosunshine
That's what I planned on doing, but there are...

That's what I planned on doing, but there are changes to OB1, OB100, FB250, FB258 and FC250. Those FBs and FCs are safety related and will require a re-compile of the safety logic, right? And, I am...
Forum: LIVE PLC Questions And Answers January 23rd, 2015, 09:38 AM
Replies: 15
Views: 1,859
Posted By psychosunshine
I was told that when you upload the HWConfig,...

I was told that when you upload the HWConfig, that there are things lost in the upload that will not exist. SO, I was hesitant to do that. If you don't lose anything, can you describe how to do...
Forum: LIVE PLC Questions And Answers January 22nd, 2015, 09:52 AM
Replies: 15
Views: 1,859
Posted By psychosunshine
I could use the old project with the old, known...

I could use the old project with the old, known good hw config. Although, there have been lots of changes to the code since December 18 when that archive was created.

Right now, my known fix is...
Forum: LIVE PLC Questions And Answers January 22nd, 2015, 07:04 AM
Replies: 15
Views: 1,859
Posted By psychosunshine
http://foxautomation.com/images/Untitled2.png

http://foxautomation.com/images/Untitled2.png