Search: Posts Made By: Webhead
Forum: LIVE PLC Questions And Answers April 16th, 2018, 01:33 PM
Replies: 1
Views: 299
Posted By Webhead
The help files are very handy when trying to...

The help files are very handy when trying to figure out the different functions. I assume you are bursting to a MDLC Gateway?
Forum: LIVE PLC Questions And Answers January 11th, 2018, 04:31 PM
Replies: 3
Views: 438
Posted By Webhead
If I'm reading the cutsheet correctly, Brown goes...

If I'm reading the cutsheet correctly, Brown goes to +24VDC, blue to (-) terminal on plc input and black to (+) terminal on PLC. If that doesn't get you where you want to be let us know.
Forum: LIVE PLC Questions And Answers January 11th, 2018, 04:22 PM
Replies: 2
Views: 332
Posted By Webhead
Your biggest problem is Motorola don't make that...

Your biggest problem is Motorola don't make that product anymore. It was phased out over 10 years ago. Feasibly you could connect one of the comm ports to another Motorola PLC and write code to...
Forum: LIVE PLC Questions And Answers September 20th, 2017, 08:55 AM
Replies: 5
Views: 511
Posted By Webhead
We are already doing this but I was looking for a...

We are already doing this but I was looking for a better way.
Forum: LIVE PLC Questions And Answers September 20th, 2017, 08:40 AM
Replies: 5
Views: 511
Posted By Webhead
We use Motorola ACE3600 PLCs.

We use Motorola ACE3600 PLCs.
Forum: LIVE PLC Questions And Answers September 19th, 2017, 01:14 PM
Replies: 5
Views: 511
Posted By Webhead
Exclamation PLC Backup Software - Source Safe??????

We now have a second programmer on staff. I was the main person touching all of our PLC programs and we never really had a problem with backups of software. Now I find that having a second guy can...
Forum: LIVE PLC Questions And Answers August 22nd, 2017, 01:45 PM
Replies: 14
Views: 8,667
Posted By Webhead
What did it cost if you don't mind me asking?

What did it cost if you don't mind me asking?
Forum: LIVE PLC Questions And Answers July 25th, 2017, 03:00 PM
Replies: 2
Views: 1,026
Posted By Webhead
That is not correct at all..... If the memory...

That is not correct at all..... If the memory has been wiped from the CPU the default IP is 10.100.100.100
Forum: LIVE PLC Questions And Answers July 25th, 2017, 02:55 PM
Replies: 2
Views: 1,303
Posted By Webhead
I wish i would have looked at this thread before...

I wish i would have looked at this thread before buying the software...... Grrrrr
Forum: LIVE PLC Questions And Answers July 25th, 2017, 02:53 PM
Replies: 5
Views: 1,121
Posted By Webhead
I've been using it and it is very buggy. Instead...

I've been using it and it is very buggy. Instead of just re-loading the report you modified I have found it's better to re-load the whole project. The software is not as user friendly as the...
Forum: LIVE PLC Questions And Answers February 8th, 2017, 11:05 AM
Replies: 2
Views: 723
Posted By Webhead
It's a government job. Pay can be negotiable with...

It's a government job. Pay can be negotiable with right candidate.
Forum: LIVE PLC Questions And Answers February 8th, 2017, 07:12 AM
Replies: 1
Views: 1,167
Posted By Webhead
If you have a copy of the program and config you...

If you have a copy of the program and config you can blank out the PLC and reload the program with your own password. But, if it is communication with other PLCs in the same network it will not...
Forum: LIVE PLC Questions And Answers February 8th, 2017, 07:08 AM
Replies: 2
Views: 723
Posted By Webhead
Job Opportunity - Seminole County, FL

Seminole County is looking for an Industrial Programmer with some experience to perform jobs for both water and waste water facilities. All interested should click on the link and apply for the...
Forum: LIVE PLC Questions And Answers November 3rd, 2016, 09:10 AM
Replies: 2
Views: 606
Posted By Webhead
Do you give access tot he "File" menu after a...

Do you give access tot he "File" menu after a supervisor logs on. If so they could click Special>Security>Configure Users and do it that way. Or you could set the system tag to $ConfigureUsers = 1...
Forum: LIVE PLC Questions And Answers October 7th, 2015, 06:51 AM
Replies: 5
Views: 1,222
Posted By Webhead
We have always had good luck with these: ...

We have always had good luck with these:
...
Forum: LIVE PLC Questions And Answers October 5th, 2015, 09:59 AM
Replies: 3
Views: 2,431
Posted By Webhead
GE Proficy ME latest version?

Can someone tell me the latest version of Proficy Machine Edition? I had a contractor use 8.6 and we have 8.0 so I am unable to load his project let alone download anything if I need to. Thanks in...
Forum: LIVE PLC Questions And Answers September 30th, 2015, 06:18 AM
Replies: 7
Views: 921
Posted By Webhead
Well that shows my ignorance with Step 7. I'm...

Well that shows my ignorance with Step 7. I'm glad you were able to get a solution.
Forum: LIVE PLC Questions And Answers September 28th, 2015, 07:16 AM
Replies: 7
Views: 921
Posted By Webhead
Can you say "Change Order"? I would use a PID...

Can you say "Change Order"? I would use a PID function. You should be able to accomplish your task by configuring the parameters correctly.

Does the Siemens have a For Next capability? ...
Forum: LIVE PLC Questions And Answers August 26th, 2015, 03:58 PM
Replies: 4
Views: 934
Posted By Webhead
Very good idea. I'm just getting ready to deploy...

Very good idea. I'm just getting ready to deploy AccessAnywhere pretty soon. So not sure if web app will overide OS. I do that it is using a computer him client so it might. Won't really know until...
Forum: LIVE PLC Questions And Answers August 26th, 2015, 01:25 PM
Replies: 4
Views: 934
Posted By Webhead
If InTouch is running on the tablet then InTouch...

If InTouch is running on the tablet then InTouch is in charge of the touch controls and should override the OS for long press.
Forum: LIVE PLC Questions And Answers September 4th, 2014, 03:13 PM
Replies: 7
Views: 1,770
Posted By Webhead
We just tried using it last week and it failed...

We just tried using it last week and it failed miserably.....
Forum: LIVE PLC Questions And Answers December 13th, 2013, 09:12 AM
Replies: 15
Views: 2,849
Posted By Webhead
I don't have anything special but I have been...

I don't have anything special but I have been known to ask the question what is x = x + 1? Usually if they have any programming skills whatsoever they can answer this quickly. If you get the blank...
Forum: LIVE PLC Questions And Answers December 13th, 2013, 09:09 AM
Replies: 6
Views: 3,743
Posted By Webhead
It would be a nice feature but unfortunately not.

It would be a nice feature but unfortunately not.
Forum: LIVE PLC Questions And Answers January 28th, 2013, 01:39 PM
Replies: 14
Views: 16,303
Posted By Webhead
Thanks Russ, the values I needed were hard coded...

Thanks Russ, the values I needed were hard coded into the comments above the PID blocks.
Forum: LIVE PLC Questions And Answers January 28th, 2013, 11:50 AM
Replies: 14
Views: 16,303
Posted By Webhead
Thanks Steve. That was just what I needed.

Thanks Steve. That was just what I needed.