Search: Posts Made By: janner_10
Forum: LIVE PLC Questions And Answers Yesterday, 03:54 PM
Replies: 15
Views: 325
Posted By janner_10
Over here, yes. It is classed as a live conductor...

Over here, yes. It is classed as a live conductor and should be treated so.
Forum: LIVE PLC Questions And Answers Yesterday, 03:38 PM
Replies: 22
Views: 537
Posted By janner_10
If you were paid to build a panel over here and...

If you were paid to build a panel over here and sent it with no ferrules, it would be thrown back in your face and you would get told to do it properly.

I guess different continents, different...
Forum: LIVE PLC Questions And Answers April 14th, 2019, 02:01 AM
Replies: 12
Views: 545
Posted By janner_10
This is the sort of garbage I would expect from a...

This is the sort of garbage I would expect from a bean counter.
Forum: LIVE PLC Questions And Answers March 29th, 2019, 03:39 PM
Replies: 20
Views: 1,387
Posted By janner_10
Many years ago, this was the last resort to...

Many years ago, this was the last resort to finding a breaker! There we no fancy gadgets, you just cut, mind you, this was on T&E, sod doing on SWA!
Forum: LIVE PLC Questions And Answers March 28th, 2019, 10:37 AM
Replies: 13
Views: 747
Posted By janner_10
On a few trips to the states, I've thought this,...

On a few trips to the states, I've thought this, but there seems to be a big obsession with arc'ing for some reason.

Obviously both done wrong is quite bad, but not something I've ever understood....
Forum: LIVE PLC Questions And Answers March 27th, 2019, 04:08 PM
Replies: 7
Views: 371
Posted By janner_10
Thanks for taking the time for that Ken - it...

Thanks for taking the time for that Ken - it worked very well.
Forum: LIVE PLC Questions And Answers March 26th, 2019, 05:37 PM
Replies: 7
Views: 371
Posted By janner_10
The results make no sense - However the customer...

The results make no sense - However the customer just wants a unique number so, thinking as I type the Hex thing may be a red herring!
Forum: LIVE PLC Questions And Answers March 26th, 2019, 03:30 PM
Replies: 7
Views: 371
Posted By janner_10
Array of SINTs (Hex) to Strings

We have a IFM DTE102 RFID Reader. PLC is L82E v32

It presents the results into an array of SINTs, I have to select HEX as the style in the tag editor so it matches with the IFM web browser...
Forum: LIVE PLC Questions And Answers March 19th, 2019, 04:23 PM
Replies: 3
Views: 446
Posted By janner_10
Not helpful, but we got attracted by the 755...

Not helpful, but we got attracted by the 755 safety over EIP for a project, won't make that mistake again.
Forum: LIVE PLC Questions And Answers March 19th, 2019, 04:20 PM
Replies: 4
Views: 544
Posted By janner_10
With that kind of simple control, I would...

With that kind of simple control, I would probably just make a UDT and copy the couple of rungs 7 times.
Forum: LIVE PLC Questions And Answers March 19th, 2019, 03:59 PM
Replies: 18
Views: 1,034
Posted By janner_10
Keep it a secret!

Keep it a secret!
Forum: LIVE PLC Questions And Answers March 19th, 2019, 03:47 PM
Replies: 9
Views: 513
Posted By janner_10
This needs to be more of a one way street, you...

This needs to be more of a one way street, you tell the customer what can or cannot be done both legally and safely and how much it will cost.

If they don't have the money, then walk away.
...
Forum: LIVE PLC Questions And Answers March 15th, 2019, 06:32 AM
Replies: 18
Views: 1,494
Posted By janner_10
I probably do around 100 projects a year, 80%...

I probably do around 100 projects a year, 80% being bespoke. I wish I had time to mess about with stuff like this but experience has taught me, KEEP IT SIMPLE!

When you return in 3 years to make...
Forum: LIVE PLC Questions And Answers March 15th, 2019, 06:26 AM
Replies: 20
Views: 1,560
Posted By janner_10
I could see it being semi-useful for monitoring...

I could see it being semi-useful for monitoring state of digital IO or analogue values, as an actual touchscreen for control - seems a bit of a daft idea.
Forum: LIVE PLC Questions And Answers March 9th, 2019, 11:41 AM
Replies: 7
Views: 818
Posted By janner_10
For the sake of a $5 relay and $5 sounder, it...

For the sake of a $5 relay and $5 sounder, it removes another thing for an operator to think about, which is never bad.

If you control the heater via your PLC, anything that now goes wrong, will...
Forum: LIVE PLC Questions And Answers February 27th, 2019, 02:54 PM
Replies: 8
Views: 678
Posted By janner_10
Yes you are. We don't buy anything directly from...

Yes you are. We don't buy anything directly from Siemens and setting up a web account for downloading was pretty straight forward.
Forum: LIVE PLC Questions And Answers February 26th, 2019, 02:05 PM
Replies: 17
Views: 817
Posted By janner_10
No disrespect intended, but the fact you have...

No disrespect intended, but the fact you have come here asking questions proves your are outside of you're area of competence.

It's been many years since I was a practicing electrician, but this...
Forum: LIVE PLC Questions And Answers February 22nd, 2019, 03:14 PM
Replies: 6
Views: 385
Posted By janner_10
Good points, I'll add to my list on Monday -...

Good points, I'll add to my list on Monday - Thanks
Forum: LIVE PLC Questions And Answers February 22nd, 2019, 02:48 PM
Replies: 6
Views: 385
Posted By janner_10
Neither, I just want the damn thing to run at the...

Neither, I just want the damn thing to run at the speed I tell it to.

EDIT: It is set to Speed Control Open Loop.
Forum: LIVE PLC Questions And Answers February 22nd, 2019, 01:24 PM
Replies: 6
Views: 385
Posted By janner_10
The speed Ref readout pretty much mirrors the AI...

The speed Ref readout pretty much mirrors the AI Signal, so I've no concerns on that front.

Good point about the Keypad Ref, I will try that Monday.
Forum: LIVE PLC Questions And Answers February 22nd, 2019, 12:16 PM
Replies: 6
Views: 385
Posted By janner_10
Danfoss FC51 Output Issue

This is the first time I've had the pleasure of setting one of these up.

It's a little 1.5kw, 3p 400v one running a centrifugal fan, 1.1kw motor.

It's speed reference is via 0-10v Analogue...
Forum: LIVE PLC Questions And Answers February 21st, 2019, 02:23 AM
Replies: 15
Views: 919
Posted By janner_10
KISS: I would reboot the panel and observe...

KISS:

I would reboot the panel and observe the version number when it boots up.
Forum: LIVE PLC Questions And Answers February 15th, 2019, 06:29 PM
Replies: 9
Views: 583
Posted By janner_10
What's your suggestion then?

What's your suggestion then?
Forum: LIVE PLC Questions And Answers February 15th, 2019, 02:41 PM
Replies: 9
Views: 583
Posted By janner_10
KISS MyCounterINT := MyCounterINT +1;

KISS

MyCounterINT := MyCounterINT +1;
Forum: LIVE PLC Questions And Answers February 15th, 2019, 11:49 AM
Replies: 17
Views: 822
Posted By janner_10
If your using v32, you can also rename the...

If your using v32, you can also rename the elements of a UDT online also, which is handy.
Showing results 1 to 25 of 500

 