Search: Posts Made By: Leukic
Forum: LIVE PLC Questions And Answers December 2nd, 2019, 02:49 PM
Replies: 4
Views: 400
Posted By Leukic
Seperated motor from power booted drive up and no...

Seperated motor from power booted drive up and no fault. looks like im searching for a motor. Thanks OkiePc
Forum: LIVE PLC Questions And Answers December 2nd, 2019, 01:54 PM
Replies: 4
Views: 400
Posted By Leukic
ABB ACS550 Earth Fault

I just replaced this drive as the old one went out when the plant had a power surge/flicker.

1-Installed the drive
2-Powered up
3- Got an immediate EARTH FAULT, so I check the manual and it...
Forum: LIVE PLC Questions And Answers November 19th, 2019, 01:24 PM
Replies: 4
Views: 434
Posted By Leukic
Thanks Ken!

Thanks Ken!
Forum: LIVE PLC Questions And Answers November 19th, 2019, 12:16 PM
Replies: 4
Views: 434
Posted By Leukic
I found it. Just as I read you reply a little bit...

I found it. Just as I read you reply a little bit ago. When our engineer set up this stuff under config he forgot to set the status of the inputs they were set as NOT USED. Not sure why I didnt...
Forum: LIVE PLC Questions And Answers November 19th, 2019, 11:06 AM
Replies: 4
Views: 434
Posted By Leukic
1734-AENTR Input light issue

Gaurdlogix 5380 tied into 1734-AENTR. Safety scanner ossd1 and ossd2 are in I0 and I1 respectively. Common is hooked to 4&5. When we reset the scanner we get 24vdc from the scanner at the terminals...
Forum: LIVE PLC Questions And Answers August 27th, 2019, 12:44 PM
Replies: 18
Views: 1,029
Posted By Leukic
I have learned some stuff today. Thanks Ken and...

I have learned some stuff today. Thanks Ken and Genius. That worked and now I can connect via ethernet and my 1747uic.
Forum: LIVE PLC Questions And Answers August 27th, 2019, 12:25 PM
Replies: 18
Views: 1,029
Posted By Leukic
Ken https://ibb.co/qCLQk4T This is my...

Ken
https://ibb.co/qCLQk4T
This is my computer

And here is the rest of the arp -a
https://ibb.co/P5htPXG
Forum: LIVE PLC Questions And Answers August 27th, 2019, 11:36 AM
Replies: 18
Views: 1,029
Posted By Leukic
Alright BREAKTHROUGH!!! I feel stupid. The slc...

Alright BREAKTHROUGH!!! I feel stupid. The slc has a rs232 AIC to a DH485 link coupler to be able to run the hmi on the panel. I just unplugged the hmi and plugged in my 1747uic and magic.

Ken...
Forum: LIVE PLC Questions And Answers August 27th, 2019, 11:20 AM
Replies: 18
Views: 1,029
Posted By Leukic
After a few hours of updating the computer last...

After a few hours of updating the computer last night at home, I was hoping that would solve the issue.

I just left a machine and was able to connect to it via the 1747uic rs485 with NO issues....
Forum: LIVE PLC Questions And Answers August 26th, 2019, 02:11 PM
Replies: 18
Views: 1,029
Posted By Leukic
I am not able to connect via iP address in a web...

I am not able to connect via iP address in a web browser. I am starting to suspect my laptop as I can open up a web browser on the desktop
Forum: LIVE PLC Questions And Answers August 26th, 2019, 01:06 PM
Replies: 18
Views: 1,029
Posted By Leukic
Let me finish lunch and I'll get back out on the...

Let me finish lunch and I'll get back out on the computer lol
Forum: LIVE PLC Questions And Answers August 26th, 2019, 01:04 PM
Replies: 18
Views: 1,029
Posted By Leukic
I can ping the plc via cmd prompt on the laptop. ...

I can ping the plc via cmd prompt on the laptop.
The plc device shows up as unrecognized in rslinx on the laptop but shows up on the desktop
Forum: LIVE PLC Questions And Answers August 26th, 2019, 12:47 PM
Replies: 18
Views: 1,029
Posted By Leukic
Can not Connect to SLC 5/05

Hey everyone! It has been a while since I have had an issue to post about but here I am back to gather some knowledge from yall.

SLC5/05 talks to an desktop computer with VIA Ethernet to trend the...
Forum: LIVE PLC Questions And Answers June 28th, 2019, 01:15 PM
Replies: 7
Views: 897
Posted By Leukic
The person who wrote this programs uses BSL to...

The person who wrote this programs uses BSL to sequence the steps in which it stores and restores the data.
I was able to put a test bit in the restore data rung. This same issue happened 2 days...
Forum: LIVE PLC Questions And Answers June 23rd, 2019, 07:12 PM
Replies: 7
Views: 897
Posted By Leukic
YES Just the buttons Ken. Yes read/write. The...

YES Just the buttons Ken. Yes read/write. The initial values where written when we made the product set up. but it can be adjusted via the buttons via hmi screen and written back to the file. and...
Forum: LIVE PLC Questions And Answers June 23rd, 2019, 12:52 AM
Replies: 7
Views: 897
Posted By Leukic
We did have a power failure that day, during...

We did have a power failure that day, during working hours for the operators (after I was gone) My Electrical Engineers told me to just not worry about how it happened cause they couldn't know how. ...
Forum: LIVE PLC Questions And Answers June 20th, 2019, 09:55 AM
Replies: 7
Views: 897
Posted By Leukic
RSlogix data files...

I had a belt that conveys brick with multiple moves, stops and runs.. Each brick which is different has a different product setup for certain pulls and move lengths.

Now basically at the end of...
Forum: LIVE PLC Questions And Answers June 18th, 2019, 09:06 PM
Replies: 4
Views: 732
Posted By Leukic
I figured it out Jeev. I had to add the ip...

I figured it out Jeev. I had to add the ip address back to the movistudio for the drive.

Got the drive able to run via movistudio. Somehow I removed it. THanks for the input.:beerchug:
Forum: LIVE PLC Questions And Answers June 17th, 2019, 01:51 PM
Replies: 4
Views: 732
Posted By Leukic
We have a desktop that is connected to the...

We have a desktop that is connected to the machine via ethernet. So I downloaded movitools on it since I could not get it to work for me on my laptop.

Jeev, today I installed a new drive...
Forum: LIVE PLC Questions And Answers June 14th, 2019, 01:56 PM
Replies: 4
Views: 732
Posted By Leukic
How to connect to SEW MOVIDRIVE

Sew Movidrive is model MDX61B0150-203-4-OT.

It is connected via Ethernet to STudio5000.
I have a seperation belt that this drive controls and we had a power surge wednesday. I can manually...
Forum: LIVE PLC Questions And Answers May 16th, 2019, 08:11 AM
Replies: 9
Views: 739
Posted By Leukic
I have been going through and labeling them ...

I have been going through and labeling them tedious but worth it.
Forum: LIVE PLC Questions And Answers May 14th, 2019, 08:48 AM
Replies: 9
Views: 739
Posted By Leukic
Finally got an email back from the company that...

Finally got an email back from the company that makes the saw. With pdf files of the electrical schematic. This will help tremendously as it wil be slow going in the plc. Still don't know ****...
Forum: LIVE PLC Questions And Answers May 13th, 2019, 12:06 PM
Replies: 9
Views: 739
Posted By Leukic
SLC03-4 are the same way. grrr

SLC03-4 are the same way. grrr
Forum: LIVE PLC Questions And Answers May 13th, 2019, 10:37 AM
Replies: 9
Views: 739
Posted By Leukic
Siemens S7-200 NO bit description?

First time looking at Siemens. Our thin brick saw would not go system ON which by troubleshooting the wiring it was an issue with an ESTOP. But upon looking in the PLC. I found no information...
Forum: LIVE PLC Questions And Answers March 27th, 2019, 12:43 PM
Replies: 20
Views: 1,963
Posted By Leukic
wonder if both hots are coming from the same leg?

wonder if both hots are coming from the same leg?