Forum: LIVE PLC Questions And Answers Yesterday, 05:01 PM
Replies: 3
Views: 165
Posted By ASF
I think what you're looking for is indirect...

I think what you're looking for is indirect addressing.


For example, assuming recipe 0 is stored in N240:60, recipe 1 is stored in N240:61, and so on...recipe 9 is stored in N240:69.


In...
Forum: LIVE PLC Questions And Answers Yesterday, 04:54 PM
Replies: 20
Views: 825
Posted By ASF
Screenshot of a v30.11 project with an L16ER-BB1B...

Screenshot of a v30.11 project with an L16ER-BB1B that I just set up for testing.

I agree with Ken and the others - you are setting yourself up for a huge fall if you persist with this option....
Forum: LIVE PLC Questions And Answers Yesterday, 04:30 PM
Replies: 12
Views: 477
Posted By ASF
All you people mixing your cutlery are playing a...

All you people mixing your cutlery are playing a dangerous game...


https://imgs.xkcd.com/comics/forks_and_spoons.png


Apologies to xkcd
Forum: LIVE PLC Questions And Answers January 19th, 2020, 10:34 PM
Replies: 10
Views: 615
Posted By ASF
842E-SIP? Shouldn't you be using a multi-turn...

842E-SIP? Shouldn't you be using a multi-turn encoder for this, rather than a single turn? I mean, you can use a single turn and handle the rollover in the PLC if you want, provided it's rotating...
Forum: LIVE PLC Questions And Answers January 16th, 2020, 04:56 PM
Replies: 2
Views: 228
Posted By ASF
If Chris' post is correct, perhaps you could...

If Chris' post is correct, perhaps you could within your UDT create an expression BOOL tag, and put the expression in there. Then bind your enabled tag property to that expression tag?
Forum: LIVE PLC Questions And Answers January 16th, 2020, 04:53 PM
Replies: 9
Views: 340
Posted By ASF
I would 100% recommend a virtual machine...

I would 100% recommend a virtual machine solution. I use VMWare and have found it extraordinarily stable and reliable.

Small caveat - my host is a mac, so I'm using VMWare Fusion, the mac...
Forum: LIVE PLC Questions And Answers January 14th, 2020, 07:59 PM
Replies: 4
Views: 235
Posted By ASF
The version I dealt with (this is back in...

The version I dealt with (this is back in 2010-2011, but the PLC's had been around much longer) was installed on Windows XP. Shortly before I left that role, the workstation was upgraded to Windows...
Forum: LIVE PLC Questions And Answers January 14th, 2020, 04:48 PM
Replies: 1
Views: 126
Posted By ASF
It's possible - Siemens have an application...

It's possible - Siemens have an application example here...
Forum: LIVE PLC Questions And Answers January 14th, 2020, 04:35 PM
Replies: 4
Views: 235
Posted By ASF
I've only used the older modicon quantum PLC's,...

I've only used the older modicon quantum PLC's, but they used Proworx 32. Maybe start there, if that's not correct it might at least lead you in the right direction.
Forum: LIVE PLC Questions And Answers January 13th, 2020, 04:26 PM
Replies: 4
Views: 243
Posted By ASF
The above advice is all correct - if you're using...

The above advice is all correct - if you're using a 1769 safety controller, you'll have to add a 1734-AENT(R) to your ethernet tree and put some 1734-IB8S and 1734-OB8S on a separate chassis. I have...
Forum: LIVE PLC Questions And Answers January 13th, 2020, 12:04 AM
Replies: 10
Views: 615
Posted By ASF
Honestly, spend the money on an ethernet/IP...

Honestly, spend the money on an ethernet/IP encoder and save your $ on development time. With a 140M-E encoder you'll have it up and running so fast that unless your time is worthless, I'd almost...
Forum: LIVE PLC Questions And Answers January 12th, 2020, 11:58 PM
Replies: 10
Views: 455
Posted By ASF
I would cuss and stomp if I found someone...

I would cuss and stomp if I found someone bringing a 120V lighting circuit into my PLC control panel just because they didn't want to interface it properly :handball:

Personally, I'd put a small...
Forum: LIVE PLC Questions And Answers January 12th, 2020, 11:55 PM
Replies: 10
Views: 462
Posted By ASF
If all you need to do is to reset the fault, you...

If all you need to do is to reset the fault, you can probably install it and just run it using the 7 day grace period. As long as you don't install/open the software until less than 7 days before you...
Forum: LIVE PLC Questions And Answers January 12th, 2020, 05:06 PM
Replies: 4
Views: 424
Posted By ASF
This approach is almost exactly how I got into...

This approach is almost exactly how I got into the field. Whenever my shift was quiet and nothing much needed doing, I'd get online with a PLC and poke around until I found something I didn't...
Forum: LIVE PLC Questions And Answers January 9th, 2020, 07:58 PM
Replies: 11
Views: 1,032
Posted By ASF
Interesting! How did you read all that data from...

Interesting! How did you read all that data from the drive without data links? I'd imagine you could do it with a message instruction, but then message instructions within AOI's are a huge PITA in my...
Forum: LIVE PLC Questions And Answers January 9th, 2020, 04:39 PM
Replies: 11
Views: 524
Posted By ASF
+1 to this. It amazes me how often I come across...

+1 to this. It amazes me how often I come across PID instructions not properly timed. It's not just a problem for when you upgrade your processor, it means your PID loop will get mroe and more...
Forum: LIVE PLC Questions And Answers January 8th, 2020, 04:48 PM
Replies: 9
Views: 343
Posted By ASF
P.S. here's a couple of those threads on the...

P.S. here's a couple of those threads on the prescan operations, should you be interested

http://www.plctalk.net/qanda/showthread.php?t=92064
http://www.plctalk.net/qanda/showthread.php?t=110282...
Forum: LIVE PLC Questions And Answers January 8th, 2020, 04:39 PM
Replies: 9
Views: 343
Posted By ASF
S:FS should without exception be on for the first...

S:FS should without exception be on for the first scan whether the processor has switched from program to run, or been power cycled. If your logic isn't behaving as you expect, I'd bet significantly...
Forum: LIVE PLC Questions And Answers January 7th, 2020, 07:48 PM
Replies: 4
Views: 690
Posted By ASF
The default option is the default for good reason...

The default option is the default for good reason - in most applications, that's the best option to use. It means that you can remove a faulty series A input module and replace it with a newer series...
Forum: LIVE PLC Questions And Answers January 7th, 2020, 05:21 PM
Replies: 9
Views: 646
Posted By ASF
I ended up splitting that question into a...

I ended up splitting that question into a separate thread for clarity, ran some tests, and found more or less just that.


http://www.plctalk.net/qanda/showthread.php?t=122967&page=2
Forum: LIVE PLC Questions And Answers December 29th, 2019, 06:00 PM
Replies: 11
Views: 530
Posted By ASF
Sometimes when there's a particularly riveting...

Sometimes when there's a particularly riveting news story unfolding (like Australia's biennial leadership spill) I like to have the live news blog giving me notifications with each new post, so I...
Forum: LIVE PLC Questions And Answers December 29th, 2019, 04:38 PM
Replies: 106
Views: 5,890
Posted By ASF
Another thing that electrics have over...

Another thing that electrics have over traditional fuel vehicles when it comes to range is that, provided you remember to plug it in, you always leave home with a "full tank", something you can't do...
Forum: LIVE PLC Questions And Answers December 23rd, 2019, 04:50 PM
Replies: 32
Views: 2,009
Posted By ASF
What infuriates me even more is people who write...

What infuriates me even more is people who write "Kpa" instead of "kPa". There are two abbreviations in those three letters, and you got them both wrong!
Forum: LIVE PLC Questions And Answers December 22nd, 2019, 04:47 PM
Replies: 11
Views: 684
Posted By ASF
Dustin (dmroeder) has developed a python script...

Dustin (dmroeder) has developed a python script to read a Control/Compact Logix, he's posted it here before. Others exist as well.

You could probably have the PLC read the port statistics by using...
Forum: LIVE PLC Questions And Answers December 17th, 2019, 08:34 PM
Replies: 20
Views: 865
Posted By ASF
Shouldn't that read 1756-L6x and 1769-L32E/L35E?