You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 304
Search took 0.05 seconds.
Search: Posts Made By: kalabdel
Forum: LIVE PLC Questions And Answers Today, 09:43 AM
Replies: 2
Views: 87
Posted By kalabdel
Thanks Bob. It pops up when it wants to and it...

Thanks Bob. It pops up when it wants to and it doesn't display anything of value and though it looks resizeable I could not resize it. And after reading your reply I went back to look for it and...
Forum: LIVE PLC Questions And Answers Yesterday, 09:45 AM
Replies: 2
Views: 87
Posted By kalabdel
CX-Programmer Data Monitor

Hello everyone,

What is this little window for?

Thanks
Forum: LIVE PLC Questions And Answers July 13th, 2018, 01:43 PM
Replies: 7
Views: 285
Posted By kalabdel
It turns out uploading parameters is not possible...

It turns out uploading parameters is not possible which means the address mapping of existing devices will have to be derived from the program.
Forum: LIVE PLC Questions And Answers July 13th, 2018, 11:15 AM
Replies: 7
Views: 285
Posted By kalabdel
Got the cable, using cx-profibus I added a device...

Got the cable, using cx-profibus I added a device right clicked and selected Go Online or Upload Parameters and I keep getting and error message "No Device Assignment" ! What does that mean?

...
Forum: LIVE PLC Questions And Answers July 12th, 2018, 10:03 AM
Replies: 10
Views: 302
Posted By kalabdel
Thanks guys. I am heading back today for a second...

Thanks guys. I am heading back today for a second look. The error has to do with I/O but I forgot to take a screenshot or it and will do that later.
The power supply is P2 120VAC to 24VDV and the...
Forum: LIVE PLC Questions And Answers July 11th, 2018, 10:47 PM
Replies: 10
Views: 407
Posted By kalabdel
If you are able to connect then you should be...

If you are able to connect then you should be able to download the program I think with .exob extension and decompile in the software. I had the same issue last year and Keith helped me through it.
Forum: LIVE PLC Questions And Answers July 11th, 2018, 10:18 PM
Replies: 10
Views: 302
Posted By kalabdel
SLC500 CUP power flicker

Hello everyone,

I have a SLC 5/03 with two racks, the first with 10 I/Os and the second with 12. The CPU intermittently restarts looking like it lost power . It's very quick but enough to reset...
Forum: LIVE PLC Questions And Answers July 9th, 2018, 06:03 PM
Replies: 1
Views: 106
Posted By kalabdel
Found it. Thanks

Found it. Thanks
Forum: LIVE PLC Questions And Answers July 9th, 2018, 05:51 PM
Replies: 1
Views: 106
Posted By kalabdel
Slc 500/03 battery replacement

Where is the battery located ? Is it on the left side of the cpu hidden by the power supply?

Thanks
Forum: LIVE PLC Questions And Answers July 7th, 2018, 01:03 AM
Replies: 10
Views: 407
Posted By kalabdel
I believe the USB is done only with a USB stick...

I believe the USB is done only with a USB stick not direct connection to PC. The procedure is somewhere out there in one of the manuals.
...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 04:26 PM
Replies: 7
Views: 285
Posted By kalabdel
Thanks Bob. Here's a pic of the I/O. Slot #5 had...

Thanks Bob. Here's a pic of the I/O. Slot #5 had the RPOFIBUS master (I'm not user why it appears as Analog module as I have pictures of the hardware and it is definitely in that spot.)

From the...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 12:09 PM
Replies: 7
Views: 285
Posted By kalabdel
Thanks Gary. I did review those two manual and ...

Thanks Gary. I did review those two manual and and two more for two days and couldn't find any of the memory areas that could be allocated based on the unit number anywhere in the code.
I'm...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 03:49 AM
Replies: 7
Views: 285
Posted By kalabdel
C200HS memory mapping for PROFIBUS master

Hello everyone,

I have a copy of a program with very few named tags and no comments, which is typical. I have been trying to find out which memory is mapped to the PROFIBUS master PRM21 and can't...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 03:30 AM
Replies: 26
Views: 1,300
Posted By kalabdel
I second Wiha, I have quite a bit of their tool...

I second Wiha, I have quite a bit of their tool and have been very happy with them.
Forum: LIVE PLC Questions And Answers June 29th, 2018, 01:51 PM
Replies: 0
Views: 114
Posted By kalabdel
OMRON C200HW-PRM21 communication cable

Hello guys,

I need to change the configuration on an C200HW-PRM21
PROFIBUS-DP Master Unit and looking communication cable. Any one knows where to get one? Is there another way to configure the...
Forum: LIVE PLC Questions And Answers June 28th, 2018, 10:13 PM
Replies: 4
Views: 161
Posted By kalabdel
Thanks JRW, it's not your phone I think the size...

Thanks JRW, it's not your phone I think the size of the image was too large and it's *large*.
I figured it was a lot more than in and out replacement and without beiing able to connect to the CPU...
Forum: LIVE PLC Questions And Answers June 28th, 2018, 10:01 PM
Replies: 4
Views: 161
Posted By kalabdel
Thanks JRW, I replied and I don't see my reply. I...

Thanks JRW, I replied and I don't see my reply. I was having issues posting images and now I don't see my last post. I will try again.

I would like to replace the Beckhoff in the picture with an...
Forum: LIVE PLC Questions And Answers June 28th, 2018, 09:37 PM
Replies: 4
Views: 161
Posted By kalabdel
PROFIBUS: device independant

Hello everyone,


How true is PROFIBUS device independence. I have a Beckhoff BK3110 that I will replace with an SMC EX260 and I haven't been able to connect to the OMORON CPU C200HX to look at...
Forum: LIVE PLC Questions And Answers June 26th, 2018, 07:25 AM
Replies: 8
Views: 397
Posted By kalabdel
Thanks a lot. By the way I meant that my laptop...

Thanks a lot. By the way I meant that my laptop had the virus; was not implying your site, in case my comment was misunderstood.

Very much appreciated. Always a pleasure dealing with you.
...
Forum: LIVE PLC Questions And Answers June 26th, 2018, 07:05 AM
Replies: 8
Views: 397
Posted By kalabdel
Thanks for the quick reply and the usual...

Thanks for the quick reply and the usual awesome/quick service.
Now you really put the fear into me cause that could only mean one thing...VIRUS. Thankfully it's not my work unit but problematic...
Forum: LIVE PLC Questions And Answers June 25th, 2018, 08:45 PM
Replies: 8
Views: 397
Posted By kalabdel
Is there something wrong with your site? I've...

Is there something wrong with your site? I've been trying to check out with times I added to the cart and have tried two different browsers but the checkout button simply doesn't work!

I managed...
Forum: LIVE PLC Questions And Answers June 19th, 2018, 02:02 AM
Replies: 10
Views: 344
Posted By kalabdel
Thanks boneless, that project was very helpful. I...

Thanks boneless, that project was very helpful. I wish I had it a couple of months ago.
Forum: LIVE PLC Questions And Answers June 18th, 2018, 08:26 AM
Replies: 10
Views: 344
Posted By kalabdel
I've used the ET 200sp version of that and I...

I've used the ET 200sp version of that and I believe they're quire similar in configuration.

Are you using it with s7-1200 or s7-1500? The hardware configuration differs for the two and the latter...
Forum: LIVE PLC Questions And Answers June 15th, 2018, 01:05 PM
Replies: 8
Views: 397
Posted By kalabdel
Thanks Bullzi. Much appreciated.

Thanks Bullzi. Much appreciated.
Forum: LIVE PLC Questions And Answers June 15th, 2018, 12:47 PM
Replies: 8
Views: 397
Posted By kalabdel
Mircologix communication cable, 90Deg or striaght?

Hello everyone,

From experience which is better for field use, 90 deg or straight and why? I a inclined to buy the straight one but started wondering if there's something I'm missing as I...
Showing results 1 to 25 of 304

 