You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 0.28 seconds.
Search: Posts Made By: geniusintraining
Forum: LIVE PLC Questions And Answers Today, 10:59 AM
Replies: 7
Views: 132
Posted By geniusintraining
Hi Dock and SamTheLightMaster, You can use...

Hi Dock and SamTheLightMaster,

You can use starter, developer or pro for the 1400's, you just need to pay more, see the link below, its a download PDF
...
Forum: LIVE PLC Questions And Answers Today, 09:23 AM
Replies: 5
Views: 132
Posted By geniusintraining
What is the error? are you uploading the same...

What is the error? are you uploading the same version? I have seen that a issue before, do you have a offline project that you can edit in place of the upload?
Forum: LIVE PLC Questions And Answers Today, 09:20 AM
Replies: 7
Views: 132
Posted By geniusintraining
Yes you need to upgrade, I think the 1400's came...

Yes you need to upgrade, I think the 1400's came out in V8ish

9324-RLM0100ENE cost about $150.00, contact your local AB dealer
Forum: LIVE PLC Questions And Answers Today, 06:30 AM
Replies: 5
Views: 132
Posted By geniusintraining
Also... if it has a popup you should be able to...

Also... if it has a popup you should be able to click 'try again' and locate it in RSLinx, this will assign the mac/ip address to the project and the next time it should not fail
Forum: LIVE PLC Questions And Answers October 23rd, 2020, 01:01 PM
Replies: 18
Views: 607
Posted By geniusintraining
Automation folks dont retire... they just come to...

Automation folks dont retire... they just come to PLCTalk and help the younger ones :D
Forum: LIVE PLC Questions And Answers October 23rd, 2020, 10:15 AM
Replies: 18
Views: 607
Posted By geniusintraining
First I would want more than one switch... ...

First I would want more than one switch...

Float at the top to Stop the fill pump
Float at the bottom to Start the fill pump

And some people have another at the top and bottom for safety, if...
Forum: LIVE PLC Questions And Answers October 23rd, 2020, 06:44 AM
Replies: 2
Views: 292
Posted By geniusintraining
Contact your local Mitsubishi supplier, they can...

Contact your local Mitsubishi supplier, they can give you a copy for free or very close to it... start building relationships because you will need them someday
Forum: LIVE PLC Questions And Answers October 22nd, 2020, 04:57 PM
Replies: 21
Views: 957
Posted By geniusintraining
There is such a thing as a Fault Routine, the PLC...

There is such a thing as a Fault Routine, the PLC will run the routine for one scan after the fault happens, I think you would need to use this and store it in a non volatile memory... I remember...
Forum: LIVE PLC Questions And Answers October 22nd, 2020, 06:42 AM
Replies: 16
Views: 722
Posted By geniusintraining
Not that I would know anything about the UK......

Not that I would know anything about the UK... but I would think they are like here in the states and its more the 'industry' not so much the location, if I walk into a feedmill I am almost positive...
Forum: LIVE PLC Questions And Answers October 20th, 2020, 10:17 AM
Replies: 10
Views: 485
Posted By geniusintraining
Man if this works we should charge more, if it...

Man if this works we should charge more, if it can stop the trivial calls it would be priceless :D
Forum: LIVE PLC Questions And Answers October 20th, 2020, 08:35 AM
Replies: 10
Views: 485
Posted By geniusintraining
Thanks Mark! Paul, The SD's are easy to...

Thanks Mark!


Paul, The SD's are easy to set up and load, I have a few now with different programs and firmwares loaded on them, see here...
Forum: LIVE PLC Questions And Answers October 20th, 2020, 06:50 AM
Replies: 22
Views: 984
Posted By geniusintraining
Allen-Bradley, 9324-RL0300ENE, ESD - RSLogix 500...

Allen-Bradley, 9324-RL0300ENE, ESD - RSLogix 500 Standard $3,806.00

Allen-Bradley, 9324-RL0700NXENE, ESD - RSLogix 500 Professional $6,864.00
Forum: LIVE PLC Questions And Answers October 19th, 2020, 02:08 PM
Replies: 14
Views: 509
Posted By geniusintraining
Everyone told you what you need... you may even...

Everyone told you what you need... you may even find a copy of GX Developer and that would work, here is the how with a USB cable

Mitsubishi SC09 and SC09-FX...
Forum: LIVE PLC Questions And Answers October 19th, 2020, 02:06 PM
Replies: 14
Views: 509
Posted By geniusintraining
Then thats a good enough reason for me :beerchug:

Then thats a good enough reason for me :beerchug:
Forum: LIVE PLC Questions And Answers October 19th, 2020, 11:36 AM
Replies: 14
Views: 509
Posted By geniusintraining
I agree, just buy a newer Mitsubishi and keep on...

I agree, just buy a newer Mitsubishi and keep on using it... its given you years of service so no reason to spend the money to convert the program and you will also only need to buy one software...
Forum: LIVE PLC Questions And Answers October 18th, 2020, 12:40 PM
Replies: 3
Views: 327
Posted By geniusintraining
Thank you!... anyone else looking...

Thank you!... anyone else looking https://www.automationdirect.com/microsites/clickplcs/click-help/Content/109.htm
Forum: LIVE PLC Questions And Answers October 18th, 2020, 07:52 AM
Replies: 3
Views: 327
Posted By geniusintraining
OK, I think I have it but.... one part of the...

OK, I think I have it but.... one part of the program in the Click is getting stuck, when you power the PLC on I have a bit that is staying true, I can not find a 'first scan bit' in the Click...
Forum: LIVE PLC Questions And Answers October 17th, 2020, 09:26 AM
Replies: 21
Views: 957
Posted By geniusintraining
I am with everyone else and send it back but......

I am with everyone else and send it back but... just out of curiosity, remove everything and the program then does it still do it?
Forum: LIVE PLC Questions And Answers October 16th, 2020, 03:42 PM
Replies: 3
Views: 327
Posted By geniusintraining
BRX SD Card and Click data log

So I started a thread at the AD forum... https://community.automationdirect.com/s/question/0D53u00002O4jbSCAR/brx-sd-card-storing-v0v4095

And I am having second thoughts about what I am trying to...
Forum: LIVE PLC Questions And Answers October 15th, 2020, 07:13 AM
Replies: 9
Views: 600
Posted By geniusintraining
You dont need W 98 or a handheld, you can use...

You dont need W 98 or a handheld, you can use Windows 10 or any Windows OS works just fine, we sell a USB 1745-PCC cable that OkiePC link (Thanks Paul) and EVERYthing you need is on that page, from...
Forum: LIVE PLC Questions And Answers October 13th, 2020, 02:32 PM
Replies: 22
Views: 984
Posted By geniusintraining
Doubt the local will loan them out, they sell...

Doubt the local will loan them out, they sell them for about 3k but its worth a shot... a better chance is they will stop by and upload the program for you, back in the day my local did not have a...
Forum: LIVE PLC Questions And Answers October 13th, 2020, 01:20 PM
Replies: 8
Views: 369
Posted By geniusintraining
Try uploading and comparing what you have to...

Try uploading and comparing what you have to whats in the PLC, then download the same program you uploaded



Read below
Forum: LIVE PLC Questions And Answers October 13th, 2020, 11:59 AM
Replies: 15
Views: 791
Posted By geniusintraining
What are you doing with them? I dont know enough...

What are you doing with them? I dont know enough (yet) but we just started selling a serial to Ethernet Modbus adapter called MOXA MB3180, I need more time to play with them but so far they seem...
Forum: LIVE PLC Questions And Answers October 13th, 2020, 11:46 AM
Replies: 22
Views: 984
Posted By geniusintraining
It would be nice to upload the program and...

It would be nice to upload the program and compare, you could buy one of our U2DHP adapters but they are out of most companies budget unless they use it a lot... I thought about doing a rental...
Forum: LIVE PLC Questions And Answers October 12th, 2020, 09:03 AM
Replies: 12
Views: 537
Posted By geniusintraining
This means there is a minor fault present ...

This means there is a minor fault present

What is the PLC, how are you trying to connect USB/Serial/Ethernet?
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -4. The time now is 02:07 PM.


.