Search: Posts Made By: theColonel26
Forum: LIVE PLC Questions And Answers November 19th, 2020, 11:42 PM
Replies: 73
Views: 6,229
Posted By theColonel26
For the record I am still here. I just haven't...

For the record I am still here. I just haven't gotten back to working on this project. Also the whole point of this thread was doing it directly. I guess I wasn't completely clear on that in my...
Forum: LIVE PLC Questions And Answers November 17th, 2020, 11:51 AM
Replies: 73
Views: 6,229
Posted By theColonel26
I found a codesys Library Specifically do to...

I found a codesys Library Specifically do to this.


https://github.com/NothinRandom/CoDeSys_EIP


I haven't tried it yet.

the author says that he handles the EIP stack himself and uses...
Forum: LIVE PLC Questions And Answers November 17th, 2020, 10:30 AM
Replies: 73
Views: 6,229
Posted By theColonel26
Yes, that is just an enum supplied with the...

Yes, that is just an enum supplied with the library. you should be able to send any hexdec value you want with it. My understanding is that all this is doing is sending a value that represents the...
Forum: LIVE PLC Questions And Answers November 16th, 2020, 10:24 AM
Replies: 73
Views: 6,229
Posted By theColonel26
AlfredoQuintero ...

AlfredoQuintero

(http://www.plctalk.net/qanda/member.php?u=155410)
If you select "Path defined by symbolic name" it does the conversion for you I think. So just put in the tag name.

Do you...
Forum: LIVE PLC Questions And Answers November 15th, 2020, 02:26 PM
Replies: 73
Views: 6,229
Posted By theColonel26
@dmroeder...

@dmroeder (http://www.plctalk.net/qanda/member.php?u=18330)


Do you have any incite in to this lower level stuff we are talking about?


I think so far the issues seem to be codesys related.
Forum: LIVE PLC Questions And Answers November 14th, 2020, 11:15 PM
Replies: 73
Views: 6,229
Posted By theColonel26
For the moment Yes. I guess I am a bit...

For the moment Yes.


I guess I am a bit confused. Have you read through the whole thread?


In that dialog, is the "symbolic path" I assume means "ANSI Ext. Symbolic Segment" So I still need...
Forum: LIVE PLC Questions And Answers November 14th, 2020, 09:39 PM
Replies: 73
Views: 6,229
Posted By theColonel26
I was online before that is why the add...

I was online before that is why the add connection was grayed out. I can open this dialog when off line.


See screen shot
Forum: LIVE PLC Questions And Answers November 14th, 2020, 09:34 PM
Replies: 73
Views: 6,229
Posted By theColonel26
I used the Generic EthernetIP device EDS. I...

I used the Generic EthernetIP device EDS. I assume that is what you mean.


Why do I need those connections aren't they just a mapping of class, Instance and attribute, for cyclical scanning?...
Forum: LIVE PLC Questions And Answers November 14th, 2020, 08:30 PM
Replies: 73
Views: 6,229
Posted By theColonel26
here is a screen shot of the Adapter properties. ...

here is a screen shot of the Adapter properties.

it says that adapter is not configured, But I don't know what other information it needs.

See Screen shots of Scanner and the Adapter configs....
Forum: LIVE PLC Questions And Answers November 14th, 2020, 08:10 PM
Replies: 73
Views: 6,229
Posted By theColonel26
ooooooh so they were being politically correct......

ooooooh so they were being politically correct... Yeah Master/Slave is just less confusing.



Anyways I have wire shark running. I see ICMP packets for pings, but there is ENIP packets being...
Forum: LIVE PLC Questions And Answers November 14th, 2020, 01:25 AM
Replies: 73
Views: 6,229
Posted By theColonel26
I am actually running it in the windows runtime...

I am actually running it in the windows runtime demo at the moment.

But yeah I can launch wire shark.

by adapter I assume it means the PLC in this case, and not my computer NIC.
Forum: LIVE PLC Questions And Answers November 14th, 2020, 01:22 AM
Replies: 73
Views: 6,229
Posted By theColonel26
I don't understand what this is for ...

I don't understand what this is for


Request[8 + numBytesTagName] := 16#01; // Read 1 element LOW BYTE
Request[9 + numBytesTagName] := 16#00; // Read 1 element HIGH BYTE
Forum: LIVE PLC Questions And Answers November 14th, 2020, 12:29 AM
Replies: 73
Views: 6,229
Posted By theColonel26
ok, So this comment on Reddit explains the...

ok, So this comment on Reddit explains the example that AustralIan posted.


I though the Data I needed to send was just the tag name so I was confused by AustralIan example until I read this
...
Forum: LIVE PLC Questions And Answers November 13th, 2020, 11:45 PM
Replies: 73
Views: 6,229
Posted By theColonel26
What do you mean doesn't support Symbolic Paths....

What do you mean doesn't support Symbolic Paths. Do you just mean Tags? or is this another layer of CIP that I haven't heard of yet?

Also what is the difference between Symbolic Segment addressing...
Forum: LIVE PLC Questions And Answers November 13th, 2020, 11:35 PM
Replies: 73
Views: 6,229
Posted By theColonel26
OK I have the Win V3 Demo running and I cam...

OK I have the Win V3 Demo running and I cam connected to it with my programming running.

When I got on line it says my EtherNet/IP Scanner is not running.

I don't get it. I don't need to do...
Forum: LIVE PLC Questions And Answers November 13th, 2020, 09:17 AM
Replies: 73
Views: 6,229
Posted By theColonel26
Holy Heck!! How have I never found the 1756-pm020...

Holy Heck!! How have I never found the 1756-pm020 document before?
I didn't think there was any public documentation like this from rock well.


:beer::dance:
Forum: LIVE PLC Questions And Answers November 12th, 2020, 04:33 PM
Replies: 73
Views: 6,229
Posted By theColonel26
So based on a reply in my Reddit thread...

So based on a reply in my Reddit thread (https://www.reddit.com/r/PLC/comments/js0208/read_tag_from_rockwell_plc_from_codesys_35/) on the same topic


This is what I have so far.

only problem...
Forum: LIVE PLC Questions And Answers November 10th, 2020, 11:00 PM
Replies: 73
Views: 6,229
Posted By theColonel26
As of right now it would be a IFM CR series HMC...

As of right now it would be a IFM CR series HMC with full access to the Linux OS.
Forum: LIVE PLC Questions And Answers November 10th, 2020, 09:54 PM
Replies: 73
Views: 6,229
Posted By theColonel26
Read Tag from Rockwell PLC from Codesys?

Read Tag from Rockwell PLC from Codesys 3.5?



Rockwell PLCs would be 5370s, 5380s, 5570s, and 5580s etc.



It seems everyone's EtherNet/IP Adapters aren't tag aware, and they just use the...