Search: Posts Made By: harryting
Forum: LIVE PLC Questions And Answers July 16th, 2018, 09:16 AM
Replies: 15
Views: 444
Posted By harryting
duplicate

duplicate
Forum: LIVE PLC Questions And Answers July 16th, 2018, 09:16 AM
Replies: 15
Views: 444
Posted By harryting
I recommend you take at a look at the "Purdue"...

I recommend you take at a look at the "Purdue" ICS security level model.

the way I see it, there are some data that need to be exchanged and that's fine. But the data need to travel to...
Forum: LIVE PLC Questions And Answers July 15th, 2018, 11:30 PM
Replies: 56
Views: 4,005
Posted By harryting
i have been discussing Tesla on a finance focused...

i have been discussing Tesla on a finance focused forum for a while. One of the guy there is a total Tesla fan and the discussion turns cringe worthy at times. Every legit criticism is countered as...
Forum: LIVE PLC Questions And Answers July 12th, 2018, 04:15 PM
Replies: 5
Views: 203
Posted By harryting
Good to know Ignition is an option. Hopefully...

Good to know Ignition is an option. Hopefully other major vendors follow suit.

We have some application that requires comm between Logix and wide area SCADA. Current method is tricky and...
Forum: LIVE PLC Questions And Answers July 12th, 2018, 10:11 AM
Replies: 5
Views: 203
Posted By harryting
HMI as OPC UA Client

First, I have no affiliation with the product, just interested in the industry direction regarding OPC UA. It's been talked about a lot but I see few actual products yet but now Softing just release...
Forum: LIVE PLC Questions And Answers July 11th, 2018, 03:05 PM
Replies: 21
Views: 943
Posted By harryting
?! sorry, i just laughed. Such as the problem...

?! sorry, i just laughed. Such as the problem with my posting sometime. I meant to say that I can't put down any detail of an actual case of an ICS infection I have first hand knowledge on, not...
Forum: LIVE PLC Questions And Answers July 11th, 2018, 11:09 AM
Replies: 21
Views: 943
Posted By harryting
Speaking of awkward.. I can't say what I want to...

Speaking of awkward.. I can't say what I want to say in this forum but I'll just say that it really happens and it involves some of the biggest names you heard of. And no, you won't find it on...
Forum: LIVE PLC Questions And Answers July 11th, 2018, 10:11 AM
Replies: 4
Views: 132
Posted By harryting
I haven't done this myself but you should be able...

I haven't done this myself but you should be able to use the Excel Add-In for that. The historian manual is here:

http://help.geautomation.com/Historian55/iHistorian.htm
Forum: LIVE PLC Questions And Answers July 11th, 2018, 09:48 AM
Replies: 4
Views: 132
Posted By harryting
If you already working tags from WW, then follow...

If you already working tags from WW, then follow the same format. If not, then you need to set up the interface first. Typically, that would be an OPC Interface.
Forum: LIVE PLC Questions And Answers July 11th, 2018, 09:23 AM
Replies: 21
Views: 943
Posted By harryting
I can go on my soap box and talks for hours on...

I can go on my soap box and talks for hours on this topic, as it's been quite a pain point for me in the last few years. Some of my very condensed thoughts...

- look at this forum for example,...
Forum: LIVE PLC Questions And Answers July 10th, 2018, 01:26 PM
Replies: 21
Views: 943
Posted By harryting
Well, most techs I talk to still believes in...

Well, most techs I talk to still believes in air-gap. To be fair though, you have to be THE TARGET and if you are, no defense can really be "enough".

The video link doesn't work. I may have to...
Forum: LIVE PLC Questions And Answers July 9th, 2018, 06:31 PM
Replies: 5
Views: 218
Posted By harryting
- For serial, make sure you are using a...

- For serial, make sure you are using a null-modem cable. use auto-config feature in the serial.

- or, reset the PLC back to factory default by shorten the GND & VBB point on the PCB.

- After...
Forum: LIVE PLC Questions And Answers July 3rd, 2018, 05:37 PM
Replies: 14
Views: 404
Posted By harryting
Take Bieber back and we'll call it even.

Take Bieber back and we'll call it even.
Forum: LIVE PLC Questions And Answers July 3rd, 2018, 12:06 PM
Replies: 4
Views: 273
Posted By harryting
How are hamsters involved?

How are hamsters involved?
Forum: LIVE PLC Questions And Answers July 3rd, 2018, 11:16 AM
Replies: 39
Views: 3,344
Posted By harryting
I'm once again looking at VPN options. I know...

I'm once again looking at VPN options. I know about E Won and WebPort but it's the first time I heard about StrideLinx. Can someone who had experience with both comment on the differentiation?
Forum: LIVE PLC Questions And Answers July 2nd, 2018, 11:46 AM
Replies: 56
Views: 4,005
Posted By harryting
Just saw this story, it's from a short seller so...

Just saw this story, it's from a short seller so take it FWIW:

http://adventuresincapitalism.com/2018/07/01/ivar-kreuger-goes-green/
Forum: LIVE PLC Questions And Answers July 2nd, 2018, 10:40 AM
Replies: 56
Views: 4,005
Posted By harryting
Darn KEN, can you drive it to the Northcoast BBQ?...

Darn KEN, can you drive it to the Northcoast BBQ?

Elon has surpassed everyone's expectation on what he can accomplish but even genius, which he is, can fail. I just don't see how he can turn the...
Forum: LIVE PLC Questions And Answers July 2nd, 2018, 09:42 AM
Replies: 14
Views: 613
Posted By harryting
I bought stuff from Radwell and turned into a...

I bought stuff from Radwell and turned into a mess. It was a ProSoft module and part of the functionality was not working and that waste a lot of of time. So whatever saving I was expecting...
Forum: LIVE PLC Questions And Answers June 28th, 2018, 09:14 AM
Replies: 5
Views: 321
Posted By harryting
Are you looking for a process historian or a data...

Are you looking for a process historian or a data logger?

There are significant difference. Historian examine the data and make decision on whether the data is meaningful before storing it while...
Forum: LIVE PLC Questions And Answers June 27th, 2018, 11:34 AM
Replies: 15
Views: 736
Posted By harryting
Beach bum, I'm working on it.

Beach bum,

I'm working on it.
Forum: LIVE PLC Questions And Answers June 26th, 2018, 03:00 PM
Replies: 5
Views: 321
Posted By harryting
If the data is accessible via OPC than pretty...

If the data is accessible via OPC than pretty much any historian with an OPC Interface will work.

I'll try to sort out your requirement first and see what historian client your user would like to...
Forum: LIVE PLC Questions And Answers June 22nd, 2018, 05:20 PM
Replies: 4
Views: 709
Posted By harryting
Post over a few month old should have a different...

Post over a few month old should have a different shade or something.
Forum: LIVE PLC Questions And Answers June 22nd, 2018, 12:19 PM
Replies: 4
Views: 121
Posted By harryting
Ok, so for the EIP side of things, you are using...

Ok, so for the EIP side of things, you are using the gateway as the server(slave). Which is the way I would do it too.

You need to do a few things in the gateway with Prosoft Configuration...
Forum: LIVE PLC Questions And Answers June 22nd, 2018, 11:49 AM
Replies: 4
Views: 121
Posted By harryting
I'm not quite understanding your question. ...

I'm not quite understanding your question. Perhaps you can be a bit more specific.

ProSoft phone support is excellant, btw.

Looks like you are taking data on a one-way path from Logix to...
Forum: LIVE PLC Questions And Answers June 22nd, 2018, 10:11 AM
Replies: 3
Views: 320
Posted By harryting
Well, I think it's a matter of balance. Going to...

Well, I think it's a matter of balance. Going to have them to use a standard FB maybe one step too far and I suspect many of them will push back on that.

When I worked in an auto assembly plant...