You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 96
Search took 0.02 seconds.
Search: Posts Made By: forqnc
Forum: LIVE PLC Questions And Answers February 10th, 2021, 02:31 PM
Replies: 5
Views: 552
Posted By forqnc
Thanks George, perfect timing, just did a project...

Thanks George, perfect timing, just did a project and had the dreaded ?'s instead of text. In the panelview no languages showed up under Application settings, although in windows CE and the project...
Forum: LIVE PLC Questions And Answers February 4th, 2021, 02:35 PM
Replies: 0
Views: 189
Posted By forqnc
FactoryTalk Recipe layout changing

Hi, hope everyone is staying safe.
So I am trying to set up the RecipePlus in FactoryTalk ME.
I setup my Ingredients with 101 values for the operator to modify.
Everything looks good, until I test...
Forum: LIVE PLC Questions And Answers January 20th, 2021, 08:30 AM
Replies: 14
Views: 818
Posted By forqnc
https://www.ulstandards.com/ You have to...

https://www.ulstandards.com/

You have to create an account to be able to download the Standard
Forum: LIVE PLC Questions And Answers January 14th, 2021, 07:01 AM
Replies: 34
Views: 6,219
Posted By forqnc
Why bump a 15 year old thread :whistle:

Why bump a 15 year old thread :whistle:
Forum: LIVE PLC Questions And Answers January 7th, 2021, 07:07 AM
Replies: 2
Views: 419
Posted By forqnc
I've done a few small projects using these and...

I've done a few small projects using these and the software is free....
Forum: LIVE PLC Questions And Answers December 18th, 2020, 07:20 AM
Replies: 1
Views: 559
Posted By forqnc
MicroLogix 1400 jumper bar

Rather than bumping an old thread

http://www.plctalk.net/qanda/showthread.php?t=116475

Has there been any progress on these?
Forum: LIVE PLC Questions And Answers November 25th, 2020, 07:35 AM
Replies: 11
Views: 874
Posted By forqnc
Just to add to confusion. We bought Studio 5000...

Just to add to confusion.
We bought Studio 5000 ver 32.
Had a customer call up who had an older machine which had ver 16 (RSLogix5000).
Tried to download that version and always grayed out....
Forum: LIVE PLC Questions And Answers October 28th, 2020, 08:13 AM
Replies: 17
Views: 1,721
Posted By forqnc
Did you run an Auto-Tune? For 22 years, at my...

Did you run an Auto-Tune?
For 22 years, at my previous company, I had never ran an Auto-Tune. Now at, my current company, it is standard practice.
I have noticed a difference, in this quieter...
Forum: LIVE PLC Questions And Answers October 28th, 2020, 08:04 AM
Replies: 29
Views: 3,014
Posted By forqnc
Another vote for Teams. Had to help a customer in...

Another vote for Teams. Had to help a customer in Paraguay, just yesterday. The customer was at the machine showing me how he had wired it wrong and I was playing charades trying to show him the...
Forum: LIVE PLC Questions And Answers September 23rd, 2020, 03:53 PM
Replies: 2
Views: 664
Posted By forqnc
Thanks for the reply Ken. I found a work...

Thanks for the reply Ken.
I found a work around.
I set the drive Ethernet parameters manually.
Then connected via Ethernet and uploaded the default file.
Once the default file upload it now...
Forum: LIVE PLC Questions And Answers September 22nd, 2020, 08:19 AM
Replies: 2
Views: 664
Posted By forqnc
PF525 connecting with CCW software

Hi,
I am trying to get familiar with Allen Bradley PowerFlex drives. I have the latest version of CCW (v12) installed. I just bought a drive from EBay, brand new in the box, sticker shows firmware...
Forum: LIVE PLC Questions And Answers September 11th, 2020, 12:58 PM
Replies: 25
Views: 9,441
Posted By forqnc
One more update for future readers with the same...

One more update for future readers with the same problem.
I had a need to install RSLogix5000 ver 17 for an older machine.
Software was installed but when I opened it, it said it wasn't activated....
Forum: LIVE PLC Questions And Answers July 15th, 2020, 07:48 AM
Replies: 25
Views: 9,441
Posted By forqnc
Just wanted to update for future viewers that may...

Just wanted to update for future viewers that may have the same issue.
Once Rockwells download site corrected itself, I was able to download v27 and v30.
These installed OK, although I did get a...
Forum: LIVE PLC Questions And Answers July 14th, 2020, 03:15 PM
Replies: 9
Views: 1,056
Posted By forqnc
Thanks Dmroeder for bringing this to my attention...

Thanks Dmroeder for bringing this to my attention on the other thread.
It still seems hit or miss, but I have managed to get 5 of the seven rar files I need downloading, after they are finished I...
Forum: LIVE PLC Questions And Answers July 14th, 2020, 02:59 PM
Replies: 25
Views: 9,441
Posted By forqnc
Thanks for the quick response and clarification...

Thanks for the quick response and clarification that I should be able to download older versions OKiePC.
I had been trying that since lunch time and kept getting this screen from Rockwells site....
Forum: LIVE PLC Questions And Answers July 14th, 2020, 02:41 PM
Replies: 25
Views: 9,441
Posted By forqnc
Backwards compatibility

Sorry for bumping an old thread, but I have this same situation.
We just got Studio 5000 v32 and I need to connect to a v30 and open a v27 file.
I am new to Studio 5000 and still going through some...
Forum: LIVE PLC Questions And Answers February 6th, 2020, 10:33 AM
Replies: 18
Views: 2,057
Posted By forqnc
Why not use a Float switch which travels up and...

Why not use a Float switch which travels up and down on a pole, then take some plastic wire mesh and make a tube around it to prevent foreign objects effecting it travel.
Forum: LIVE PLC Questions And Answers January 31st, 2020, 10:22 AM
Replies: 8
Views: 1,101
Posted By forqnc
Why not just change the default [ALARM] screen to...

Why not just change the default [ALARM] screen to whatever display you want? Delete the banner and use your own.
Forum: LIVE PLC Questions And Answers January 29th, 2020, 10:18 AM
Replies: 6
Views: 919
Posted By forqnc
Aabeck, 24VDC control voltage, but right site ...

Aabeck, 24VDC control voltage, but right site
...
Forum: LIVE PLC Questions And Answers November 22nd, 2019, 10:33 AM
Replies: 1
Views: 556
Posted By forqnc
Finally got this figured out and will post in...

Finally got this figured out and will post in case someone else wishes to do it.
The Lenze SMV inverters i'm using only have 3 programmable digital inputs. I needed a forward input, reverse input...
Forum: LIVE PLC Questions And Answers November 20th, 2019, 10:00 AM
Replies: 32
Views: 5,713
Posted By forqnc
+1 I installed a Stridelink, but it only allows...

+1
I installed a Stridelink, but it only allows one person access at a time.
Installed a Tosibox, provided it with internet access, and you're connected.
Only possible downside is it connects via...
Forum: LIVE PLC Questions And Answers November 19th, 2019, 02:09 PM
Replies: 1
Views: 556
Posted By forqnc
Ethernet communication between CJ2M and Lenze SMV Drive

Hi All,
I am having issues communicating between an Omron CJ2M PLC and a Lenze SMV Drive (with Ethernet Module).
I have set up Network Configurator with 2 tags (D350 and D450) of 8 bytes in length,...
Forum: LIVE PLC Questions And Answers November 6th, 2019, 10:04 AM
Replies: 13
Views: 1,186
Posted By forqnc
I agree, why mess around, search "PLCHardware"...

I agree, why mess around, search "PLCHardware" they had 16 racks for $116. I I would post a link but it messes up when I try to preview.
Forum: LIVE PLC Questions And Answers October 22nd, 2019, 03:43 PM
Replies: 6
Views: 1,031
Posted By forqnc
mdim, thanks for the quick response. I found...

mdim, thanks for the quick response. I found where you said, but that still doesn't work. I see my auto logoff change to default but the screen doesn't change.
Forum: LIVE PLC Questions And Answers October 22nd, 2019, 02:47 PM
Replies: 6
Views: 1,031
Posted By forqnc
Thanks for the responses, but I must be missing...

Thanks for the responses, but I must be missing something. I found the check box as you describe, but it does nothing. Will it matter if I have 3 separate logout buttons on different screens? I have...
Showing results 1 to 25 of 96

 
Forum Jump

All times are GMT -5. The time now is 03:41 PM.


.