Forum: LIVE PLC Questions And Answers
February 24th, 2021, 10:03 AM
|
Replies: 1
Views: 136
Modbus set-up
Wizards,
I hope everyone survived the storms the last few weeks.
After everything calmed down here in Oklahoma, I was farmed out to get this Signal-fire wireless telemetry system working.
...
|
Forum: LIVE PLC Questions And Answers
February 5th, 2021, 12:21 PM
|
Replies: 4
Views: 562
******* messaging advice
Wizards,
Going to a plant next week that is having issues getting a com trol to work.
The com trol is driving some sort of camera.
I have spent some time reading up on the com trol, still don't...
|
Forum: LIVE PLC Questions And Answers
January 28th, 2021, 11:04 AM
|
Replies: 20
Views: 987
Here is the error that is logged.
Error...
Here is the error that is logged.
Error Occured In: Boolean StartRestartSwitch()
System.TimeoutException: The operation has timed out.
at NCD.AD8._Read8BitsValue()
at...
|
Forum: LIVE PLC Questions And Answers
January 27th, 2021, 02:44 PM
|
Replies: 20
Views: 987
|
Forum: LIVE PLC Questions And Answers
January 27th, 2021, 09:05 AM
|
Replies: 20
Views: 987
|
Forum: LIVE PLC Questions And Answers
January 26th, 2021, 03:35 PM
|
Replies: 1
Views: 276
Found my answer,
These controllers can...
Found my answer,
These controllers can supply their own 24v dc, there is a jumper that has to be put in to jump 24vdc to the enable, and then they become stand alone.
|
Forum: LIVE PLC Questions And Answers
January 26th, 2021, 02:57 PM
|
Replies: 20
Views: 987
Drbitboy,
I am not entirely sure, I have...
Drbitboy,
I am not entirely sure, I have reached back out to the developer but with the support I have received in the past, I don't expect a reply soon...
I will try to dig around some more to...
|
Forum: LIVE PLC Questions And Answers
January 26th, 2021, 02:36 PM
|
Replies: 1
Views: 276
Desoutter Torque Controller
Quick question,
I have a Desoutter cvic 2 controller that I was asked to make it mobile.
It is currently mounted to a huge station on wheels, that is just too big.
We would like to mount this to...
|
Forum: LIVE PLC Questions And Answers
January 26th, 2021, 02:22 PM
|
Replies: 20
Views: 987
|
Forum: LIVE PLC Questions And Answers
January 21st, 2021, 02:49 PM
|
Replies: 20
Views: 987
|
Forum: LIVE PLC Questions And Answers
January 21st, 2021, 02:44 PM
|
Replies: 20
Views: 987
|
Forum: LIVE PLC Questions And Answers
January 21st, 2021, 02:19 PM
|
Replies: 20
Views: 987
Sorry for the confusion,
The error is...
Sorry for the confusion,
The error is produced by the application.
There are 3 errors we have seen from this beast.
1.) OPC---- related to rslinx not running
2.) Relay board port------ related...
|
Forum: LIVE PLC Questions And Answers
January 21st, 2021, 12:01 PM
|
Replies: 20
Views: 987
Visual Studio Error Codes
Wizards,
I have an application that is built in Visual Studio 2019.
I have been getting an error from the program that is very generic.
The developer sent me in a direction that was not the...
|
Forum: LIVE PLC Questions And Answers
January 13th, 2021, 02:25 PM
|
Replies: 9
Views: 763
Update,
I was able to everything working as...
Update,
I was able to everything working as a proof of concept, and then I gave them the price tag to replace the items we would use out of MRO stock and now everything is on hold...
Each of you...
|
Forum: LIVE PLC Questions And Answers
January 12th, 2021, 09:59 AM
|
Replies: 9
Views: 763
Thank you for the link, I am limited to what I...
Thank you for the link, I am limited to what I already have in house.
This tester they want me to add these cameras to will only be here for 2 years and then we get a new one. All new equipment will...
|
Forum: LIVE PLC Questions And Answers
January 12th, 2021, 09:43 AM
|
Replies: 9
Views: 763
Image Capture project
Wizards,
New project came across my desk yesterday.
Basic objective:
When a product passes its functionality test, take a picture of the part and save it. Saved file must contain the...
|
Forum: LIVE PLC Questions And Answers
December 16th, 2020, 12:33 PM
|
Replies: 6
Views: 763
|
Forum: LIVE PLC Questions And Answers
November 20th, 2020, 02:32 PM
|
Replies: 15
Views: 1,699
Update,
While hardwired directly to the PLC,...
Update,
While hardwired directly to the PLC, via port 2, I was able to catch the IO start to drop. I started to randomly drop networked IO blocks, and the RTA dropped as well. These drops where...
|
Forum: LIVE PLC Questions And Answers
November 20th, 2020, 08:01 AM
|
Replies: 15
Views: 1,699
We are starting to believe that the issue is...
We are starting to believe that the issue is related to the secondary equipment that does the functionality tests.
This PLC had 2 ethernet ports on it.
Everything is run through port 1, local side...
|
Forum: LIVE PLC Questions And Answers
November 18th, 2020, 02:07 PM
|
Replies: 15
Views: 1,699
We have worries that it could be an external...
We have worries that it could be an external device that someone is plugging into the line and then disconnecting it after the fault happens.
We have a security camera recording everything that...
|
Forum: LIVE PLC Questions And Answers
November 18th, 2020, 02:02 PM
|
Replies: 15
Views: 1,699
|
Forum: LIVE PLC Questions And Answers
November 18th, 2020, 11:57 AM
|
Replies: 15
Views: 1,699
Team,
After a long day of crawling through...
Team,
After a long day of crawling through this machine, doing all the wiggle tests and watching processes run, I have not been able to "make it" crash.
I have a series of tests set up to run...
|
Forum: LIVE PLC Questions And Answers
November 17th, 2020, 11:07 AM
|
Replies: 15
Views: 1,699
Dock,
The HMI is not mapped to the IO tree,...
Dock,
The HMI is not mapped to the IO tree, the only thing mapped is the atlas Copco torque gun and 3 Keyence IV nav cameras and 1732E-16CFMG12R/A Armorblock x9
This system is behind a nat...
|
Forum: LIVE PLC Questions And Answers
November 17th, 2020, 09:04 AM
|
Replies: 15
Views: 1,699
L33R Network Drop
Team,
I have a Compact Logic L33R that is having a random network issue.
Starting about a month ago, I had my first issue with this station.
The HMI was in Error states on the indicators, and...
|
Forum: LIVE PLC Questions And Answers
October 14th, 2020, 10:46 AM
|
Replies: 8
Views: 1,072
Although these items would probably do exactly...
Although these items would probably do exactly what I need them to do, the cost will most likely be too much 95.
The maint department has been trying to get approval for something they can use for...
|