Forum: LIVE PLC Questions And Answers Today, 03:48 PM
Replies: 7
Views: 188
Posted By _Dock_
This is what he is referring to, those look like...

This is what he is referring to, those look like structured text programs to me.
Forum: LIVE PLC Questions And Answers Yesterday, 12:51 PM
Replies: 13
Views: 581
Posted By _Dock_
Update. I ran the memory test. No issues...

Update.

I ran the memory test. No issues found...

Tried safe mode again, no dice.

Ok, now its just time to rip the band aid off and start over. Proceed to a clean install using a USB...
Forum: LIVE PLC Questions And Answers March 1st, 2021, 09:59 AM
Replies: 13
Views: 581
Posted By _Dock_
I donít believe so, Iíve slated some time to jump...

I donít believe so, Iíve slated some time to jump on it tomorrow. I think it has removable/ expandable ram ports.
Forum: LIVE PLC Questions And Answers February 28th, 2021, 09:04 PM
Replies: 13
Views: 581
Posted By _Dock_
At least they’re nice enough to include a frown...

At least they’re nice enough to include a frown face for your viewing pleasure.
Forum: LIVE PLC Questions And Answers February 28th, 2021, 09:04 PM
Replies: 13
Views: 581
Posted By _Dock_
Error

Error
Forum: LIVE PLC Questions And Answers February 28th, 2021, 08:33 PM
Replies: 13
Views: 581
Posted By _Dock_
With some googling I found the mdsched.exe, Iíll...

With some googling I found the mdsched.exe, Iíll give it a shot
Forum: LIVE PLC Questions And Answers February 28th, 2021, 08:18 PM
Replies: 13
Views: 581
Posted By _Dock_
I tried enable safe mode with networking. I canít...

I tried enable safe mode with networking. I canít remember if I tried just safe mode, I can give it a shot.

No recent installs, even if I had Iíd never be able to get to it. Cant get past the...
Forum: LIVE PLC Questions And Answers February 28th, 2021, 08:15 PM
Replies: 13
Views: 581
Posted By _Dock_
This is the error I get when I try to restore.

This is the error I get when I try to restore.
Forum: LIVE PLC Questions And Answers February 28th, 2021, 08:02 PM
Replies: 13
Views: 581
Posted By _Dock_
I guess I should mention that it is win10 pro....

I guess I should mention that it is win10 pro. Can you initiate the memory test from a CMD window? Thats about all I can get to... it blue screens with the same error every restart.

It’s a 1 year...
Forum: LIVE PLC Questions And Answers February 28th, 2021, 07:51 PM
Replies: 13
Views: 581
Posted By _Dock_
Windows blue screen of death help

Had my first unrecoverable blue screen on Thursday.

I got the following error ďdriver_verifier_DMA_violationĒ

Iíve tried just about everything, done the clean, restore health, on the command...
Forum: LIVE PLC Questions And Answers February 27th, 2021, 09:36 PM
Replies: 13
Views: 870
Posted By _Dock_
Should it happen? No. But, stupid is as stupid...

Should it happen? No. But, stupid is as stupid does.

It’s been discussed on here before but the “S” in IOT stands for security.
Forum: LIVE PLC Questions And Answers February 26th, 2021, 09:45 AM
Replies: 20
Views: 679
Posted By _Dock_
Do the data arrays match from bench to field?

Do the data arrays match from bench to field?
Forum: LIVE PLC Questions And Answers February 24th, 2021, 10:01 PM
Replies: 9
Views: 412
Posted By _Dock_
Another thought, many brands of encoder will...

Another thought, many brands of encoder will rollover at zero, meaning anything above zero is a positive value, anything below zero is a negative value. You need to make sure you account for this.
...
Forum: LIVE PLC Questions And Answers February 24th, 2021, 09:58 PM
Replies: 9
Views: 412
Posted By _Dock_
As Gary said you need a homing process. Don’t...

As Gary said you need a homing process. Don’t allow any auto operation until it is completed, you will need to track this. You can program a routine to do it, or if it is simple enough you can have...
Forum: LIVE PLC Questions And Answers February 24th, 2021, 09:26 PM
Replies: 10
Views: 538
Posted By _Dock_
Isolate the network to those three devices then...

Isolate the network to those three devices then run angry ip scanner or wire shark. Process of elimination since you already know two of them, the one with the unique up address should be the c600....
Forum: LIVE PLC Questions And Answers February 22nd, 2021, 09:08 AM
Replies: 26
Views: 1,177
Posted By _Dock_
I don't know if you'd ever really know if it was...

I don't know if you'd ever really know if it was completely dry. If your insistent on reusing the damaged equipment, I would remove each device from the control circuit and test it individually. ...
Forum: LIVE PLC Questions And Answers February 18th, 2021, 01:37 PM
Replies: 14
Views: 414
Posted By _Dock_
Correct, this would be another layer to be able...

Correct, this would be another layer to be able to recognize operator errors.
Forum: LIVE PLC Questions And Answers February 18th, 2021, 01:33 PM
Replies: 14
Views: 414
Posted By _Dock_
You certainly could. However I do not, mainly...

You certainly could. However I do not, mainly because your IO status light will be flashing (send maintenance on a fritz) and I monitor the IO status in alarms to signal if it occurs.

The main...
Forum: LIVE PLC Questions And Answers February 18th, 2021, 12:45 PM
Replies: 14
Views: 414
Posted By _Dock_
James, In Rockwell land you can inhibit...

James,

In Rockwell land you can inhibit modules using the SSV instruction. You can add all the fixtures in your IO tree and then inhibit all that are not being used.

Obviously you will need...
Forum: LIVE PLC Questions And Answers February 18th, 2021, 11:17 AM
Replies: 20
Views: 1,069
Posted By _Dock_
Nevermind, my brain skipped over the 3 turn...

Nevermind, my brain skipped over the 3 turn portion of your post.
Forum: LIVE PLC Questions And Answers February 18th, 2021, 11:12 AM
Replies: 20
Views: 1,069
Posted By _Dock_
https://www.automationdirect.com/adc/shopping/cata...

https://www.automationdirect.com/adc/shopping/catalog/pushbuttons_-z-_switches_-z-_indicators/22mm_metal/potentiometers/ecx2300-5k

There is a 10K in 22mm Also.

I used these once but the cycles...
Forum: LIVE PLC Questions And Answers February 17th, 2021, 09:18 AM
Replies: 5
Views: 264
Posted By _Dock_
James, See page 41 of this manual. ...

James,

See page 41 of this manual.

https://literature.rockwellautomation.com/idc/groups/literature/documents/at/drives-at004_-en-p.pdf#page40
Forum: LIVE PLC Questions And Answers February 17th, 2021, 08:15 AM
Replies: 5
Views: 264
Posted By _Dock_
Use the startup wizard it will walk you through...

Use the startup wizard it will walk you through all the questions.
Forum: LIVE PLC Questions And Answers February 16th, 2021, 02:07 PM
Replies: 37
Views: 1,861
Posted By _Dock_
"Standards" is a relative term. Relative to...

"Standards" is a relative term. Relative to where the install is. In the USA, NFPA 79 and UL508A are the "standards" for industrial control panels.
Forum: LIVE PLC Questions And Answers February 16th, 2021, 01:32 PM
Replies: 3
Views: 222
Posted By _Dock_
You can copy (COP) the string to a DINT or INT,...

You can copy (COP) the string to a DINT or INT, then use the SWPB, then COP back to the string. There may be a better way but I know this works.