Search: Posts Made By: Operaghost
Forum: LIVE PLC Questions And Answers August 3rd, 2022, 05:09 PM
Replies: 1
Views: 218
Posted By Operaghost
My guess is that the client has cached the...

My guess is that the client has cached the information. You might try flushing the display cache from the command line when you test your client and see if that clears it up.

I don't recall the...
Forum: LIVE PLC Questions And Answers August 3rd, 2022, 04:58 PM
Replies: 5
Views: 328
Posted By Operaghost
Yeah if you can access it over Ethernet then use...

Yeah if you can access it over Ethernet then use the transfer utility. It won't have any impact on the running application. It is silent to an operator. You could use a USB, but I'm pretty sure it...
Forum: LIVE PLC Questions And Answers August 3rd, 2022, 11:12 AM
Replies: 3
Views: 346
Posted By Operaghost
Yes, you will be prompted for your user name and...

Yes, you will be prompted for your user name and password.

OG
Forum: LIVE PLC Questions And Answers August 3rd, 2022, 09:41 AM
Replies: 11
Views: 1,177
Posted By Operaghost
I think you need an activated version of RSLinx...

I think you need an activated version of RSLinx to do this. Not sure if "RSLinx Lite" does this. But it might.

If you right-click on the controller in the RSWho window of RSLinx you will see an...
Forum: LIVE PLC Questions And Answers July 22nd, 2022, 04:54 PM
Replies: 11
Views: 590
Posted By Operaghost
I was thinking the same thing :) OG

I was thinking the same thing :)

OG
Forum: LIVE PLC Questions And Answers July 22nd, 2022, 04:49 PM
Replies: 11
Views: 590
Posted By Operaghost
Understood that part. Just making the point that...

Understood that part. Just making the point that Ethernet Devices can talk to any subnet, where an EIP driver can only talk to a single subnet.

You said you are using Local, can you identify the...
Forum: LIVE PLC Questions And Answers July 22nd, 2022, 04:14 PM
Replies: 11
Views: 590
Posted By Operaghost
So does your Ethernet/IP driver see any other...

So does your Ethernet/IP driver see any other devices? That driver can only see devices on a specific subnet. If it is set to "Local" then it will only see devices on the same subnet as your...
Forum: LIVE PLC Questions And Answers July 22nd, 2022, 09:38 AM
Replies: 2
Views: 342
Posted By Operaghost
As IO_Rack mentioned, Rockwell has free telephone...

As IO_Rack mentioned, Rockwell has free telephone software that can help you with this. For UAE the number is: +44 1908 635 211

They also have an online Tech note that describes the procedure. It...
Forum: LIVE PLC Questions And Answers July 22nd, 2022, 09:28 AM
Replies: 48
Views: 2,698
Posted By Operaghost
Technology and society evolve, so our terminology...

Technology and society evolve, so our terminology evolves with it. I have no problem with moving away from the outdated terms. I used to teach classrooms full of students of many different...
Forum: LIVE PLC Questions And Answers July 21st, 2022, 09:40 AM
Replies: 10
Views: 473
Posted By Operaghost
Select OTHER for the module and enter the ID Code...

Select OTHER for the module and enter the ID Code of 10401

https://spectrumcontrols.com/download/manual-1746sc-ctr4-ctr8/

Page 25 section 3.1

OG
Forum: LIVE PLC Questions And Answers July 19th, 2022, 12:47 PM
Replies: 4
Views: 383
Posted By Operaghost
The most common cause for this type of issue is...

The most common cause for this type of issue is your Windows Display settings. On my Windows 10 machine if I right-click on the desktop I see the "Display settings" option. I don't have my W11...
Forum: LIVE PLC Questions And Answers July 18th, 2022, 04:17 PM
Replies: 8
Views: 678
Posted By Operaghost
I used 64-bit. I used them on my training laptops...

I used 64-bit. I used them on my training laptops which were a mix of different Dell laptop models.

OG
Forum: LIVE PLC Questions And Answers July 18th, 2022, 03:28 PM
Replies: 8
Views: 678
Posted By Operaghost
I used the PCMK on Windows 7 for years. It worked...

I used the PCMK on Windows 7 for years. It worked fine for me. Windows 10 was a whole different story. Pretty sure the drivers were included in RSLinx. Let me look back a few versions and see where...
Forum: LIVE PLC Questions And Answers July 12th, 2022, 03:09 PM
Replies: 8
Views: 404
Posted By Operaghost
RSLogix 5 and 500 are really annoying in that...

RSLogix 5 and 500 are really annoying in that way. If you notice when you go online, the file you had open gets closed and then opens again. It can happen so fast you might not realize it. So as it...
Forum: LIVE PLC Questions And Answers July 12th, 2022, 03:03 PM
Replies: 13
Views: 410
Posted By Operaghost
So yeah it was version 11 that bumped the number...

So yeah it was version 11 that bumped the number of screens from 25 total displays to 50 replace and 50 on top. Then a patch updated version 11.0 to a total of 100 with no distinction between types...
Forum: LIVE PLC Questions And Answers July 12th, 2022, 02:44 PM
Replies: 8
Views: 404
Posted By Operaghost
Try something when you go back online. Go to File...

Try something when you go back online. Go to File and Save As and look at the directory/folder. I suspect that it may have opened an older copy of your project that you have stored in a different...
Forum: LIVE PLC Questions And Answers July 12th, 2022, 12:10 PM
Replies: 13
Views: 410
Posted By Operaghost
In the Project Settings where you select the...

In the Project Settings where you select the Window Size, you can specify which PVPlus 7 you are using and then select whether it will execute on a Standard or Performance terminal.

There are also...
Forum: LIVE PLC Questions And Answers July 12th, 2022, 11:44 AM
Replies: 10
Views: 902
Posted By Operaghost
Just a WAG here, but probably referring to the...

Just a WAG here, but probably referring to the checkbox that says "Encrypt Password"

OG
Forum: LIVE PLC Questions And Answers July 12th, 2022, 10:51 AM
Replies: 10
Views: 902
Posted By Operaghost
I also had never heard of this utility. So I...

I also had never heard of this utility. So I thought I would give it a try, albeit using RSEmulate 500.

No go....first prompt is asking to enter the password. Even after I entered the password it...
Forum: LIVE PLC Questions And Answers July 11th, 2022, 10:08 AM
Replies: 4
Views: 285
Posted By Operaghost
What you have there should work just fine as it...

What you have there should work just fine as it is.

FactoryTalk Linx (previously RSLinx Enterprise) really was designed around the Logix 5000 family of controller. While it does support the SLC...
Forum: LIVE PLC Questions And Answers July 11th, 2022, 09:43 AM
Replies: 4
Views: 652
Posted By Operaghost
Because S:5/8 is set, it sounds like you have...

Because S:5/8 is set, it sounds like you have power issues. Replacing the controller won't necessarily solve that.

The "Run Always" bit only has an effect when cycling power to the controller. It...
Forum: LIVE PLC Questions And Answers July 6th, 2022, 12:17 PM
Replies: 12
Views: 532
Posted By Operaghost
I have seen this before. If I recall, what I did...

I have seen this before. If I recall, what I did to fix it was to delete the object from the display (but not from the images folder). Then save the display and close it. Then re-open the display and...
Forum: LIVE PLC Questions And Answers July 6th, 2022, 10:34 AM
Replies: 3
Views: 307
Posted By Operaghost
From what I see, it is stored in the Windows...

From what I see, it is stored in the Windows registry:

Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Rockwell Software\RSLinx\Drivers

I don't see them stored as files. Thus the reason for...
Forum: LIVE PLC Questions And Answers July 6th, 2022, 10:10 AM
Replies: 3
Views: 307
Posted By Operaghost
Go to your old machine and run the RSLinx Backup...

Go to your old machine and run the RSLinx Backup and Restore tool. It will allow you to Backup your current drivers to a file that you can copy to your new laptop. Then run the same utility on the...
Forum: LIVE PLC Questions And Answers July 1st, 2022, 09:58 AM
Replies: 5
Views: 479
Posted By Operaghost
The image is no longer displayed, but it was...

The image is no longer displayed, but it was there at one point. It just showed a momentary button titled Reset, and it showed a tag assigned to it. That's it. Nothing about the logic or if there...