Search: Posts Made By: harryting
Forum: LIVE PLC Questions And Answers August 4th, 2022, 06:08 PM
Replies: 3
Views: 354
Posted By harryting
I wish there are network course specifically...

I wish there are network course specifically targeting controls. I have seen some but they are almost too basic.

maybe just go through online course for CompTIA's Network Plus course. It...
Forum: LIVE PLC Questions And Answers August 4th, 2022, 06:06 PM
Replies: 4
Views: 2,998
Posted By harryting
bump an old thread. I don't see a cell card...

bump an old thread. I don't see a cell card option for Data Station Plus anymore.

We are looking for a notification system for customers. Since our customer's data (phone #, etc) will be needed...
Forum: LIVE PLC Questions And Answers July 21st, 2022, 04:16 PM
Replies: 14
Views: 1,039
Posted By harryting
I have never seen someone in this business look...

I have never seen someone in this business look at thing that way. Always a first, I suppose.

Typically, the customer owns your program and can do what ever they want with it. There are always...
Forum: LIVE PLC Questions And Answers July 20th, 2022, 12:08 PM
Replies: 2
Views: 434
Posted By harryting
OT: Windows Server Forum?

Dealing quite a bit with Windows Server and thin-client type issue lately. Our IT department deal mostly with enterprise level stuff so they aren't much of a help in this regard.

I looked around...
Forum: LIVE PLC Questions And Answers July 18th, 2022, 07:26 PM
Replies: 10
Views: 802
Posted By harryting
My thought as well. PV+ handle the program...

My thought as well.

PV+ handle the program and communication parameter separately, unlike the older Panelview.
Forum: LIVE PLC Questions And Answers July 15th, 2022, 02:41 PM
Replies: 10
Views: 659
Posted By harryting
There are many DCOM guides out there, I have them...

There are many DCOM guides out there, I have them all and none of them work all the time. It's called DCOM HELL for a reason.

Today, I wouldn't not use DCOM at all unless there are simply no...
Forum: LIVE PLC Questions And Answers June 29th, 2022, 06:04 PM
Replies: 13
Views: 789
Posted By harryting
Version 19 is not officially supported on Windows...

Version 19 is not officially supported on Windows 10. Version 20 is.


From personal experience, V19 can be a bit flaky on win10. Sometime, it opens fine, sometime it just stuck on the splash...
Forum: LIVE PLC Questions And Answers June 27th, 2022, 08:40 PM
Replies: 6
Views: 725
Posted By harryting
I hope that's not the actual language in the...

I hope that's not the actual language in the course assignment because that sounds like a complete waste of time for beginner. Yes, you can tell your instructor I said so.

They are more like...
Forum: LIVE PLC Questions And Answers June 23rd, 2022, 04:59 PM
Replies: 11
Views: 1,874
Posted By harryting
Lenovo Thinkpad without high end graphic. ...

Lenovo Thinkpad without high end graphic.

Laptop with high end graphic will consume the battery much faster, in my experience and for our type work, they are not needed.
Forum: LIVE PLC Questions And Answers June 23rd, 2022, 04:46 PM
Replies: 19
Views: 1,240
Posted By harryting
USB cable is the best option. I would also check...

USB cable is the best option. I would also check your PC's IP, if it's in a different subnet than you need to use the Ethernet Device driver to see it in RSLinx. However, you should still be able...
Forum: LIVE PLC Questions And Answers June 23rd, 2022, 04:40 PM
Replies: 19
Views: 1,240
Posted By harryting
Exactly, this "Presently the gateway is...

Exactly, this "Presently the gateway is 10.10.41.1
But the IP is (I'm assuming the IP did actually change when I set it): 10.10.40.60"

is NOT going to work. you can't have a gateway outside your...
Forum: LIVE PLC Questions And Answers June 23rd, 2022, 04:37 PM
Replies: 23
Views: 1,685
Posted By harryting
"unhoused neighbor", I call them...

"unhoused neighbor", I call them addicts.
Forum: LIVE PLC Questions And Answers June 23rd, 2022, 04:31 PM
Replies: 19
Views: 1,240
Posted By harryting
Well, that's not going to work. They are in...

Well, that's not going to work. They are in different subnet.

You shown up two different subnet, call it A and B.

Subnet A is 10.10.40.x/24, host range from 10.10.40.1 to 10.10.40.254
...
Forum: LIVE PLC Questions And Answers June 9th, 2022, 03:25 PM
Replies: 4
Views: 783
Posted By harryting
I forget, vnpmoose is right. An OPC might take...

I forget, vnpmoose is right. An OPC might take out a "connection" and there are only so many of those available on a Logix PLC.
Forum: LIVE PLC Questions And Answers June 9th, 2022, 03:23 PM
Replies: 24
Views: 3,214
Posted By harryting
Kick IT out. and if you succeed, please tell me...

Kick IT out. and if you succeed, please tell me how.
Forum: LIVE PLC Questions And Answers June 8th, 2022, 07:56 PM
Replies: 4
Views: 783
Posted By harryting
You can have as many OPC server as you want...

You can have as many OPC server as you want talking to PLC. Widelto is right, RSLinx lite will not act as an OPC server but that's beside the point. I don't see how RSLinx would conflict with...
Forum: LIVE PLC Questions And Answers June 7th, 2022, 07:52 PM
Replies: 12
Views: 1,528
Posted By harryting
DCOM: My understanding is the DCOM issue doesn't...

DCOM: My understanding is the DCOM issue doesn't have anything to do with PLC firmware revision. It's more of a Windows Update that WILL kill DCOM. DCOM is between two Windows computer and not...
Forum: LIVE PLC Questions And Answers June 7th, 2022, 02:37 PM
Replies: 28
Views: 4,634
Posted By harryting
I see a lot of place around here hires new...

I see a lot of place around here hires new graduate. There are two very good I&C school here in Washington, Bellingham Tech and Perry Technical Institute in Yakima.
Forum: LIVE PLC Questions And Answers May 27th, 2022, 04:43 PM
Replies: 19
Views: 6,991
Posted By harryting
The last reply was 2020. Oh btw, it seems AB...

The last reply was 2020. Oh btw, it seems AB discontinued 1756-TIME all together.

So the only option to sync directly to a real good PTP source is buy a GPS with PTP functionality like SEL 2488.
Forum: LIVE PLC Questions And Answers May 25th, 2022, 08:25 PM
Replies: 6
Views: 1,181
Posted By harryting
Update: We found some refurb Dell Wyze 5070...

Update:

We found some refurb Dell Wyze 5070 Thin-client for about $120 on woot (Amazon). They work great except..... all remote connection info is lost on a power loss. After some research, it...
Forum: LIVE PLC Questions And Answers May 24th, 2022, 11:23 AM
Replies: 9
Views: 1,302
Posted By harryting
For simplicity sake, I did my own logic for day...

For simplicity sake, I did my own logic for day of the week and it's very simple. The only issue with it is that you need to manually set the day of the week on PLC download/powerup.
Forum: LIVE PLC Questions And Answers May 6th, 2022, 03:00 PM
Replies: 16
Views: 2,791
Posted By harryting
From my class note on ICS cybersecurity, Zeek was...

From my class note on ICS cybersecurity, Zeek was mentioned as one of the popular IDS. Snort is another one that includes IPS ability.
Forum: LIVE PLC Questions And Answers April 18th, 2022, 04:37 PM
Replies: 2
Views: 947
Posted By harryting
Big news in our sector. Also OPC UA is affected.

Big news in our sector. Also OPC UA is affected.
Forum: LIVE PLC Questions And Answers April 14th, 2022, 11:16 AM
Replies: 5
Views: 915
Posted By harryting
Damn, that's a cool trick.

Damn, that's a cool trick.
Forum: LIVE PLC Questions And Answers April 13th, 2022, 04:39 PM
Replies: 10
Views: 1,618
Posted By harryting
I changed my game. I got a nice recliner.

I changed my game. I got a nice recliner.