Search: Posts Made By: shooter
Forum: LIVE PLC Questions And Answers May 6th, 2018, 05:03 AM
Replies: 10
Views: 3,846
Posted By shooter
please send email to shooter@home.nl, and i will...

please send email to shooter@home.nl, and i will send you some function blocks i have made myself.
Forum: LIVE PLC Questions And Answers April 27th, 2018, 04:59 PM
Replies: 9
Views: 467
Posted By shooter
You could also use simple comprssed air, and keep...

You could also use simple comprssed air, and keep the other hole closed.
Forum: LIVE PLC Questions And Answers April 27th, 2018, 04:55 PM
Replies: 7
Views: 709
Posted By shooter
check in the lib section if there are files with...

check in the lib section if there are files with same Function block name, thus you will need to delete one of them (or give it another name.
Forum: LIVE PLC Questions And Answers April 27th, 2018, 04:43 PM
Replies: 6
Views: 380
Posted By shooter
You must have a master in the system, for example...

You must have a master in the system, for example a PC or a PLCtype.
Forum: LIVE PLC Questions And Answers April 27th, 2018, 04:32 PM
Replies: 15
Views: 487
Posted By shooter
give us the old and new sensor typenumbers,...

give us the old and new sensor typenumbers, probably the festo is setup as 2-10Volt. or even 4-20mA.
checck also if the 0Volt is proper connected.
Forum: LIVE PLC Questions And Answers April 14th, 2018, 07:16 PM
Replies: 7
Views: 814
Posted By shooter
2 ms is way too long to get precision. So makethe...

2 ms is way too long to get precision. So makethe proces separate from the rest and approach it from the encoder and fill in the speed of the beld.
Forum: LIVE PLC Questions And Answers April 14th, 2018, 07:06 PM
Replies: 16
Views: 1,429
Posted By shooter
a very simple tube is enough, just buy it, or...

a very simple tube is enough, just buy it, or call the company that makes it as it is out of two parts fabricated.
Forum: LIVE PLC Questions And Answers April 14th, 2018, 06:55 PM
Replies: 2
Views: 276
Posted By shooter
in TC3 all settings can be changed, as they are...

in TC3 all settings can be changed, as they are all variables of the elements, in TC2 it was a little difficult, however there is existing a nice library to do this.
also have a look at www.oscat.de...
Forum: LIVE PLC Questions And Answers April 14th, 2018, 06:08 PM
Replies: 4
Views: 273
Posted By shooter
a pointer from a pointer is not working good, as...

a pointer from a pointer is not working good, as you are talking about memoryplaces of memoryplaces. and that is no good.
Forum: LIVE PLC Questions And Answers March 26th, 2018, 03:51 PM
Replies: 4
Views: 327
Posted By shooter
surge protection is dependent of the environment...

surge protection is dependent of the environment like explosion etc, and the working voltage, so yes your client does have a good point.
Forum: LIVE PLC Questions And Answers March 21st, 2018, 05:35 PM
Replies: 2
Views: 312
Posted By shooter
yep PWM, is not the way to do this, as the PLC is...

yep PWM, is not the way to do this, as the PLC is way too slow for thsi to get it good.
yes you can use a serial connection, (with an UNO you will need a extra serial pinning like softwareserial....
Forum: LIVE PLC Questions And Answers March 21st, 2018, 05:16 PM
Replies: 10
Views: 1,620
Posted By shooter
The sensor needs to be within the limits of the...

The sensor needs to be within the limits of the input card.a good calibration of the sensor is needed to be able to control the sensor,
same for the input card.
together you will need to see both...
Forum: LIVE PLC Questions And Answers March 21st, 2018, 05:08 PM
Replies: 8
Views: 555
Posted By shooter
It is impossible to use functions or blocks in an...

It is impossible to use functions or blocks in an array, Only variables are possible in an array, they may be segmented etc.
you can put a lot of status bytes into the array, however never put a...
Forum: LIVE PLC Questions And Answers March 21st, 2018, 04:57 PM
Replies: 39
Views: 3,237
Posted By shooter
Are there roll back brakes on both wheels, or...

Are there roll back brakes on both wheels, or only on 1
Forum: LIVE PLC Questions And Answers March 21st, 2018, 04:48 PM
Replies: 5
Views: 396
Posted By shooter
every time x is full, add one to a counter, if...

every time x is full, add one to a counter,
if counter >0 then start timer,
if timer done, {do your thing.
counter--)
Forum: LIVE PLC Questions And Answers March 5th, 2018, 03:25 PM
Replies: 6
Views: 676
Posted By shooter
A very simple dimmer is enough, as you do not...

A very simple dimmer is enough, as you do not need to control the speed, but the power.
Even a simple variac is enough.
Forum: LIVE PLC Questions And Answers January 31st, 2018, 03:31 PM
Replies: 4
Views: 262
Posted By shooter
show what you made, and light a trafficlight when...

show what you made, and light a trafficlight when park is full, and if light is on do not open the entry barier.
Forum: LIVE PLC Questions And Answers January 28th, 2018, 03:49 PM
Replies: 11
Views: 549
Posted By shooter
yes arduino is cheap, and simple to program. a...

yes arduino is cheap, and simple to program.
a stepper is very simple to program in arduino, have a look at arduino.cc
they also have a forum.
Forum: LIVE PLC Questions And Answers January 28th, 2018, 03:40 PM
Replies: 31
Views: 1,612
Posted By shooter
calculations are simpler in absolute, and yes...

calculations are simpler in absolute, and yes airpressure is a factor, however the influence is dependent of the working pressure. A stabdard gauge with bourbon pipe is changed, a newer electronic is...
Forum: LIVE PLC Questions And Answers January 25th, 2018, 04:34 PM
Replies: 7
Views: 743
Posted By shooter
Have a look at the functions on the website of...

Have a look at the functions on the website of oscat.de they are used to make the calcs in a simple way.
and yes it is enthalpy , however the moist will change the enthalpy as it takes more energy...
Forum: LIVE PLC Questions And Answers January 6th, 2018, 06:11 AM
Replies: 12
Views: 860
Posted By shooter
I would change the encoder position to 180...

I would change the encoder position to 180 degrees, as that position is not going thru zero, thus the control is better.
and use a speed control to get it fluent.
Forum: LIVE PLC Questions And Answers January 4th, 2018, 01:31 PM
Replies: 14
Views: 903
Posted By shooter
I control this type of temperatures in holds of...

I control this type of temperatures in holds of ships, with pretty simple Single Loop controls, they have everything inside one unit, complete with display, and are pretty cheap, They can have a...
Forum: LIVE PLC Questions And Answers January 4th, 2018, 01:23 PM
Replies: 11
Views: 858
Posted By shooter
In CFC like any other language try to use one...

In CFC like any other language try to use one page for a program, and use subroutines to make a complex program.
like a input routine, a control routine, a output routine, a communication block, a...
Forum: LIVE PLC Questions And Answers January 4th, 2018, 01:17 PM
Replies: 6
Views: 455
Posted By shooter
and call them only one time to start.

and call them only one time to start.
Forum: LIVE PLC Questions And Answers January 4th, 2018, 01:16 PM
Replies: 6
Views: 455
Posted By shooter
Be sure the timers are running, outside of any...

Be sure the timers are running, outside of any case, as they have to be called to see if the time is elapsed.
Showing results 1 to 25 of 500

 