Search: Posts Made By: BobB
Forum: LIVE PLC Questions And Answers June 25th, 2020, 06:26 AM
Replies: 29
Views: 1,390
Posted By BobB
Saffa - same s**t another day. Insultants I have...

Saffa - same s**t another day. Insultants I have called them since 1960 when I was an apprentice. All good - go with the flow. As long as you are getting work and making a buck. I even have...
Forum: LIVE PLC Questions And Answers June 25th, 2020, 03:19 AM
Replies: 2
Views: 158
Posted By BobB
**** file - will not open here either.

**** file - will not open here either.
Forum: LIVE PLC Questions And Answers June 23rd, 2020, 06:30 PM
Replies: 11
Views: 873
Posted By BobB
I appreciate you started the thread - men do not...

I appreciate you started the thread - men do not talk about this enough - they are just blokey and want to ignore their health. There are often warning signs for illness and probably 80% of the men I...
Forum: LIVE PLC Questions And Answers June 23rd, 2020, 04:58 PM
Replies: 11
Views: 873
Posted By BobB
Sorry to here about your plight and hope all goes...

Sorry to here about your plight and hope all goes well.


Unfortunately the PSA test is not definitive either - it is a good guide but does not pick up the cancer 100% of the time. Be careful. An...
Forum: LIVE PLC Questions And Answers June 6th, 2020, 11:12 PM
Replies: 29
Views: 1,210
Posted By BobB
Red face If this is any help this was the method used with...

If this is any help this was the method used with an Omron system. May be some clues there.
Forum: LIVE PLC Questions And Answers June 6th, 2020, 03:24 AM
Replies: 29
Views: 1,210
Posted By BobB
Team Viewer has a VPN built in. I know it has...

Team Viewer has a VPN built in. I know it has been used with Omron PLCs and HMIs for programming and for viewing as well. Hope this helps.
Forum: LIVE PLC Questions And Answers June 5th, 2020, 06:39 PM
Replies: 2
Views: 398
Posted By BobB
You need to set up an alarm history page in the...

You need to set up an alarm history page in the HMI. The standard alarm page is usually set up to allow the alarms to disappear when reset. That is why there is an alarm history page.
Forum: LIVE PLC Questions And Answers June 2nd, 2020, 12:50 AM
Replies: 2
Views: 341
Posted By BobB
Do not know them but here is a link to anonymous...

Do not know them but here is a link to anonymous employee reviews - not flash. https://www.glassdoor.com.au/Reviews/EIT-Reviews-E23841.htm
Forum: LIVE PLC Questions And Answers May 13th, 2020, 06:25 PM
Replies: 16
Views: 1,535
Posted By BobB
I have just commissioned a job with a HMS Anybus...

I have just commissioned a job with a HMS Anybus Modbus TCP to BACnet server.The BMS people just find the BACnet device on the network and upload everything from the server and they were away - that...
Forum: LIVE PLC Questions And Answers May 9th, 2020, 12:48 AM
Replies: 9
Views: 694
Posted By BobB
Here is how the Omron PLC and HMI were set up -...

Here is how the Omron PLC and HMI were set up - may be useful.
Forum: LIVE PLC Questions And Answers May 8th, 2020, 06:47 PM
Replies: 9
Views: 694
Posted By BobB
Team Viewer has a VPN built in and it has been...

Team Viewer has a VPN built in and it has been successfully used to connect to Omron PLCs if that will help at all. If you want the instructions let me know and I will post them for you.
Forum: LIVE PLC Questions And Answers May 7th, 2020, 02:49 AM
Replies: 18
Views: 1,062
Posted By BobB
I use Omron Ethernet I/O all the time. 16 inputs...

I use Omron Ethernet I/O all the time. 16 inputs about $80 AU - 16 outputs not much more. 8 analogue inputs around $340 AU and 4 RTD inputs about the same. I even use them in the switch board...
Forum: LIVE PLC Questions And Answers May 1st, 2020, 06:20 PM
Replies: 16
Views: 1,120
Posted By BobB
Slip rings at that low voltage I have found to be...

Slip rings at that low voltage I have found to be a nightmare. They get dirty and all sorts of things. The best slip rings I ever found were the mercury bottle ones.
Forum: LIVE PLC Questions And Answers April 30th, 2020, 07:03 PM
Replies: 36
Views: 2,875
Posted By BobB
Not so - I have been combining power supplies...

Not so - I have been combining power supplies through bridge rectifiers and diodes for 20 odd years without an issue.


Meanwell also have diode combiners for sale and power supplies that can just...
Forum: LIVE PLC Questions And Answers April 29th, 2020, 10:58 PM
Replies: 36
Views: 2,875
Posted By BobB
Try Meanwell - they have power supplies with load...

Try Meanwell - they have power supplies with load sharing lines you can connect between them.
Forum: LIVE PLC Questions And Answers April 25th, 2020, 02:52 AM
Replies: 36
Views: 2,875
Posted By BobB
I normally use bridge rectifiers for this. When...

I normally use bridge rectifiers for this. When idling one power supply may supply most of the power but when the load goes up they equalise through the bridge rectifiers.
Forum: LIVE PLC Questions And Answers April 25th, 2020, 02:49 AM
Replies: 5
Views: 651
Posted By BobB
Really good post for us Aussies. Very different...

Really good post for us Aussies. Very different this year - no public services due to COVID-19 of course.

I do miss going to the Air Force base in Wagga Wagga with my brother in law at 4AM for the...
Forum: LIVE PLC Questions And Answers April 25th, 2020, 02:41 AM
Replies: 34
Views: 2,548
Posted By BobB
Oh how I agree! I am from Oz and many of us have...

Oh how I agree! I am from Oz and many of us have wicked senses of humour - most Americans do not understand us at all. I am now getting old (76)and still powering along fortunately. Have never been...
Forum: LIVE PLC Questions And Answers April 24th, 2020, 03:21 AM
Replies: 10
Views: 523
Posted By BobB
I had a look at this stuff trying to save a $....

I had a look at this stuff trying to save a $. Too dear - too big - I am much better off with the Omron offering - smaller - cheaper - 2 Ethernet ports for loop in/loop out.
Forum: LIVE PLC Questions And Answers April 21st, 2020, 03:10 AM
Replies: 18
Views: 942
Posted By BobB
Do not know what your issue is but it works in...

Do not know what your issue is but it works in the simulator for me unchanged.
Forum: LIVE PLC Questions And Answers April 17th, 2020, 04:00 AM
Replies: 18
Views: 942
Posted By BobB
That is what I am getting at. The operational...

That is what I am getting at. The operational section has to be before the END.
Forum: LIVE PLC Questions And Answers April 17th, 2020, 02:07 AM
Replies: 18
Views: 942
Posted By BobB
Is the end instruction before the rung in...

Is the end instruction before the rung in question?
Forum: LIVE PLC Questions And Answers April 16th, 2020, 04:09 AM
Replies: 5
Views: 503
Posted By BobB
Many jobs are being specified here in Oz with the...

Many jobs are being specified here in Oz with the redundant Schneider M580 PLCs and Ethernet IP I/O - the Schneider Ethernet cards can be set up in a ring and when the ring is broken at 1 point there...
Forum: LIVE PLC Questions And Answers April 15th, 2020, 03:49 AM
Replies: 158
Views: 23,671
Posted By BobB
Ah Liam - the black box looks very familiar LOL.

Ah Liam - the black box looks very familiar LOL.
Forum: LIVE PLC Questions And Answers April 14th, 2020, 03:38 PM
Replies: 158
Views: 23,671
Posted By BobB
Wrong model - my apologies. The Hitachi ones were...

Wrong model - my apologies. The Hitachi ones were the ones I meant - cannot remember the model numbers now - too long ago. They were a black box I think.
Showing results 1 to 25 of 500

 