You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 0.19 seconds.
Search: Posts Made By: gclshortt
Forum: LIVE PLC Questions And Answers Today, 05:17 AM
Replies: 4
Views: 97
Posted By gclshortt
Serial RS232 is the cable and signal that is...

Serial RS232 is the cable and signal that is being used. You need to look at the protocol in order to determine the number of receivers (Slaves) you can have for the transmitting device (Master)....
Forum: LIVE PLC Questions And Answers June 13th, 2019, 06:54 PM
Replies: 18
Views: 9,828
Posted By gclshortt
Yes, you are correct. Regards,

Yes, you are correct.

Regards,
Forum: LIVE PLC Questions And Answers June 13th, 2019, 02:22 PM
Replies: 18
Views: 9,828
Posted By gclshortt
The following code will explain the read function...

The following code will explain the read function in the VBA Code.

If (wsTCP.State = 7) Then
MbusQuery = Chr(0) + Chr(0) + Chr(0) + Chr(0) + Chr(0) + Chr(6) + Chr(0) + Chr(1) + Chr(0) + Chr(13) +...
Forum: LIVE PLC Questions And Answers June 12th, 2019, 02:35 PM
Replies: 3
Views: 189
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=8710...

http://www.plctalk.net/qanda/showthread.php?t=87109

The above thread may help you out.
Regards,
Forum: LIVE PLC Questions And Answers June 10th, 2019, 06:54 AM
Replies: 31
Views: 1,900
Posted By gclshortt
+1 Lynx777 Make sure you ask the operators for...

+1 Lynx777
Make sure you ask the operators for their opinion. Try to get them to help in the process as best you can. It will save you a lot of time in the future.
Forum: LIVE PLC Questions And Answers June 8th, 2019, 04:20 PM
Replies: 6
Views: 370
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=1035...

http://www.plctalk.net/qanda/showthread.php?t=103561

https://literature.rockwellautomation.com/idc/groups/literature/documents/um/1771-um668_-en-p.pdf

The above links may help you out.
Regards,
Forum: LIVE PLC Questions And Answers June 8th, 2019, 04:14 PM
Replies: 1
Views: 185
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=1040...

http://www.plctalk.net/qanda/showthread.php?t=104087

http://www.plctalk.net/qanda/showthread.php?t=120737

The above links may help you out.
Regards,
Forum: LIVE PLC Questions And Answers June 4th, 2019, 07:25 AM
Replies: 19
Views: 1,081
Posted By gclshortt
https://www.schneider-electric.com/en/brands/elau/...

https://www.schneider-electric.com/en/brands/elau/

I would start with the manufacturer's website. Enter your exact part number.
Regards,
Forum: LIVE PLC Questions And Answers June 3rd, 2019, 07:28 AM
Replies: 11
Views: 782
Posted By gclshortt
Having well-written code goes a long way in...

Having well-written code goes a long way in testing your code.
Sometimes you can test parts of your code by wiring on the bench some components and test that specific part of the program. (Forcing...
Forum: LIVE PLC Questions And Answers June 1st, 2019, 05:59 AM
Replies: 6
Views: 526
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=1135...

http://www.plctalk.net/qanda/showthread.php?t=113570

http://www.plctalk.net/qanda/showthread.php?t=47950

http://www.plctalk.net/qanda/showthread.php?t=85989

The above links may help you out....
Forum: LIVE PLC Questions And Answers May 30th, 2019, 09:27 AM
Replies: 2
Views: 303
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=5234...

http://www.plctalk.net/qanda/showthread.php?t=52345

http://www.plctalk.net/qanda/showthread.php?t=114673

http://www.plctalk.net/qanda/showthread.php?t=71489

The above threads may help you...
Forum: LIVE PLC Questions And Answers May 30th, 2019, 09:21 AM
Replies: 9
Views: 810
Posted By gclshortt
AD BRX Data Logging Function ...

AD BRX Data Logging Function
https://accautomation.ca/brx-plc-data-logging/

AD BRX Email / SMS / Secure Email Function
https://accautomation.ca/brx-plc-email-text-sms-messaging-gmail
...
Forum: LIVE PLC Questions And Answers May 28th, 2019, 01:00 PM
Replies: 2
Views: 252
Posted By gclshortt
Program mode? Program not transferred to the...

Program mode?
Program not transferred to the controller?

Just a thought.
Regards,
Forum: LIVE PLC Questions And Answers May 28th, 2019, 06:59 AM
Replies: 5
Views: 537
Posted By gclshortt
+1 cool

+1 cool
Forum: LIVE PLC Questions And Answers May 28th, 2019, 06:58 AM
Replies: 1
Views: 209
Posted By gclshortt
https://www.electrotechnik.net/2012/05/economy-res...

https://www.electrotechnik.net/2012/05/economy-resistor-in-dc-coils.html

"to limit the current after the contactor has operated, a series resistance is connected. This is known as the economy...
Forum: LIVE PLC Questions And Answers May 21st, 2019, 06:05 AM
Replies: 1
Views: 164
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=6384...

http://www.plctalk.net/qanda/showthread.php?t=63845

http://www.plctalk.net/qanda/showthread.php?t=96801

http://www.plctalk.net/qanda/showthread.php?t=83013

The above links may help you out....
Forum: LIVE PLC Questions And Answers May 13th, 2019, 01:54 PM
Replies: 3
Views: 358
Posted By gclshortt
http://www.industrialcontrolsonline.com/training/o...

http://www.industrialcontrolsonline.com/training/online/basics-pid-control-proportionalintegralderivative

The above article might help you out.
Regards,
Forum: LIVE PLC Questions And Answers May 13th, 2019, 07:10 AM
Replies: 10
Views: 1,019
Posted By gclshortt
Or Monday!

Or Monday!
Forum: LIVE PLC Questions And Answers May 10th, 2019, 08:56 AM
Replies: 1
Views: 269
Posted By gclshortt
https://accautomation.ca/series/omron-plc-cp1h-ser...

https://accautomation.ca/series/omron-plc-cp1h-series/

The above is a series on the CP1H Omron Controller.
You will find scaling in the data control post:...
Forum: LIVE PLC Questions And Answers May 3rd, 2019, 09:47 AM
Replies: 1
Views: 249
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=1053...

http://www.plctalk.net/qanda/showthread.php?t=105375

http://www.plctalk.net/qanda/showthread.php?t=88150

http://www.plctalk.net/qanda/showthread.php?t=48807

The above threads may help you...
Forum: LIVE PLC Questions And Answers May 1st, 2019, 11:57 AM
Replies: 24
Views: 1,329
Posted By gclshortt
If you change your baud rate will you get fewer...

If you change your baud rate will you get fewer errors?
This may be a good experiment. If you receive fewer errors, I would then check your cable and connection installation.

Regards,
Forum: LIVE PLC Questions And Answers April 30th, 2019, 07:00 AM
Replies: 2
Views: 202
Posted By gclshortt
The consumer heartbeat time defines the expected...

The consumer heartbeat time defines the expected heartbeat cycle time (ms) and must be higher than the corresponding producer heartbeat time configured on the device producing this heartbeat....
Forum: LIVE PLC Questions And Answers April 30th, 2019, 06:50 AM
Replies: 1
Views: 150
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=9341...

http://www.plctalk.net/qanda/showthread.php?t=93413

The above thread may help you out.
Regards,
Forum: LIVE PLC Questions And Answers April 27th, 2019, 08:22 AM
Replies: 6
Views: 328
Posted By gclshortt
I'm not sure what sensor you are using, but you...

I'm not sure what sensor you are using, but you could always use an output of the PLC to remove power from the sensor and look for the signal to be off.

Just a thought.
Regards,
Forum: LIVE PLC Questions And Answers April 26th, 2019, 02:37 PM
Replies: 10
Views: 428
Posted By gclshortt
https://www.automationdirect.com/stride What...

https://www.automationdirect.com/stride

What about something like StrideLinx. This would take care of your security.
Just a thought.
Regards,
Showing results 1 to 25 of 500

 