Forum: LIVE PLC Questions And Answers Today, 10:47 AM
Replies: 2
Views: 171
Posted By Ken Moore
Does the Q for I13 stay on or is pulsed? You...

Does the Q for I13 stay on or is pulsed?
You could use a RS block with I13 connected to SET, then have the RS block drive a TON timer, the output of the time drives the Q. The question is what...
Forum: LIVE PLC Questions And Answers Today, 05:37 AM
Replies: 7
Views: 171
Posted By Ken Moore
Nothing attached/uploaded.

Nothing attached/uploaded.
Forum: LIVE PLC Questions And Answers Today, 04:48 AM
Replies: 19
Views: 6,277
Posted By Ken Moore
I know this is old, but one thing you have to...

I know this is old, but one thing you have to keep in mind is down time. A complete rip out/re-wire takes a lot of time, and Time is money.
Forum: LIVE PLC Questions And Answers Yesterday, 02:09 PM
Replies: 4
Views: 130
Posted By Ken Moore
A quick search gave me this: ...

A quick search gave me this:
https://support.microsoft.com/en-us/help/213612/how-to-run-a-macro-when-certain-cells-change-in-excel
Forum: LIVE PLC Questions And Answers June 18th, 2019, 04:51 PM
Replies: 4
Views: 191
Posted By Ken Moore
Search for "resilent mounts", it's what we used...

Search for "resilent mounts", it's what we used in the Navy to quite down machinery noise and vibration.

These look interesting: http://www.greenerubber.com/shock-and-vibration/
Forum: LIVE PLC Questions And Answers June 18th, 2019, 10:03 AM
Replies: 6
Views: 203
Posted By Ken Moore
Same concept, plug in the numbers held in the two...

Same concept, plug in the numbers held in the two registers to get the final F: address.
Forum: LIVE PLC Questions And Answers June 18th, 2019, 09:49 AM
Replies: 6
Views: 203
Posted By Ken Moore
First one: Starting at N49:12 copy 15 registers...

First one:
Starting at N49:12 copy 15 registers to N[Value stored in N48:0]:[Value stored in N48:39]

So if N48:0 was 13, and N48:39 was 0, then the destination would be N13:0 plus the next 14...
Forum: LIVE PLC Questions And Answers June 18th, 2019, 08:03 AM
Replies: 13
Views: 372
Posted By Ken Moore
Is there a chance that this drive is jogged or...

Is there a chance that this drive is jogged or ran manually in the field sometimes?
I have encountered this when the drive is run outside the PLC logic, in Reverse. The logic did not have anything...
Forum: LIVE PLC Questions And Answers June 18th, 2019, 04:22 AM
Replies: 7
Views: 778
Posted By Ken Moore
There were some pretty significant changes made...

There were some pretty significant changes made between 8.0 and 9.0. What is the status of the OPC Server in your FactoryTalk project? Is the name correct? Can you see the tags with the FT OPC tools?
Forum: LIVE PLC Questions And Answers June 17th, 2019, 10:01 AM
Replies: 8
Views: 376
Posted By Ken Moore
Sounds like he is doing some type of building...

Sounds like he is doing some type of building Heating/Cooling systems. Turning on Loop pumps etc.. Not sure about Tenn. but in some states, the standard regulations start at a certain size, say...
Forum: LIVE PLC Questions And Answers June 15th, 2019, 04:35 AM
Replies: 4
Views: 281
Posted By Ken Moore
Thanks for returning and sharing the solution. ...

Thanks for returning and sharing the solution.
Maybe someone else will benefit from your experience.
Forum: LIVE PLC Questions And Answers June 14th, 2019, 02:51 PM
Replies: 61
Views: 2,280
Posted By Ken Moore
I qualify. I think you are mistaken though, he...

I qualify.
I think you are mistaken though, he used "Naught" as in: "Double Naught Spy"
:beerchug:
Forum: LIVE PLC Questions And Answers June 14th, 2019, 02:44 PM
Replies: 2
Views: 192
Posted By Ken Moore
The position of your project controller has to...

The position of your project controller has to match the position in the emulator, do you have it in Slot-2? Most folks use Slot 0 for the controller, I recommend you re-arrange your emulator to...
Forum: LIVE PLC Questions And Answers June 14th, 2019, 11:21 AM
Replies: 61
Views: 2,280
Posted By Ken Moore
I often add more information to the description. ...

I often add more information to the description.
Such as:
Screw Speed Switch
1=Ok to run
Forum: LIVE PLC Questions And Answers June 14th, 2019, 11:18 AM
Replies: 21
Views: 1,270
Posted By Ken Moore
If you do form your own company, be careful what...

If you do form your own company, be careful what you call it. I have a friend that had his own programming company for awhile. He named it XXX Engineering. In South Carolina if you have Engineering...
Forum: LIVE PLC Questions And Answers June 14th, 2019, 11:13 AM
Replies: 30
Views: 1,636
Posted By Ken Moore
Not 100% destroyed, but I did lose all my data. ...

Not 100% destroyed, but I did lose all my data.

Working a startup, laptop on a folding table, guy walks by, tangles his feed in the power cords, rips laptop off table onto floor, hard drive died...
Forum: LIVE PLC Questions And Answers June 13th, 2019, 04:04 PM
Replies: 28
Views: 1,472
Posted By Ken Moore
TW, when your youngest child leaves home and your...

TW, when your youngest child leaves home and your wife says "Let's have another baby!" Then you can start your crisis!
Forum: LIVE PLC Questions And Answers June 13th, 2019, 02:58 PM
Replies: 9
Views: 405
Posted By Ken Moore
IF you are not using fault tags, just use the...

IF you are not using fault tags, just use the P_AIn instead of the P_AIChan
Forum: LIVE PLC Questions And Answers June 13th, 2019, 02:17 PM
Replies: 21
Views: 1,270
Posted By Ken Moore
I left my previous employer last Feb. and...

I left my previous employer last Feb. and considered trying the "contractor" role. Lots of liability insurance needed by most plants. You may need other things too.

I decided to go through a local...
Forum: LIVE PLC Questions And Answers June 13th, 2019, 02:11 PM
Replies: 9
Views: 405
Posted By Ken Moore
Does it look like this? You need the fault...

Does it look like this? You need the fault connections.
Forum: LIVE PLC Questions And Answers June 13th, 2019, 01:23 PM
Replies: 9
Views: 405
Posted By Ken Moore
I mis-understood, you are using the Basic AI...

I mis-understood, you are using the Basic AI block and faceplate. When you said created, I thought you rolled your own.

In the function block what do you have connected to Inp_PVBad? Should be...
Forum: LIVE PLC Questions And Answers June 13th, 2019, 11:34 AM
Replies: 9
Views: 405
Posted By Ken Moore
When you say "display is showing a signal...

When you say "display is showing a signal failure", are speaking of the faceplate or an Icon? Did you create your own Icon too, or are just showing a value?
NaN means Not a Number.
I've never...
Forum: LIVE PLC Questions And Answers June 13th, 2019, 10:05 AM
Replies: 10
Views: 322
Posted By Ken Moore
For basic scaling try this thread: ...

For basic scaling try this thread:
http://www.plctalk.net/qanda/showthread.php?t=109295&highlight=basic+scaling

Depending on Platform, there may be built in scaling tools, that do the scaling for...
Forum: LIVE PLC Questions And Answers June 13th, 2019, 08:23 AM
Replies: 28
Views: 1,472
Posted By Ken Moore
I consider it "traveling" if you are sleeping at...

I consider it "traveling" if you are sleeping at a Hotel/Motel.

I don't mind it so much, if I can be home for the weekends.
Forum: LIVE PLC Questions And Answers June 13th, 2019, 06:37 AM
Replies: 28
Views: 1,472
Posted By Ken Moore
I have played around with a few BACNET devices,...

I have played around with a few BACNET devices, similar, but different.
I would think more travel, lots of service calls. But...nicer working conditions, I hope.