On power up you must home all encoders
that...
On power up you must home all encoders
that may mean that you need to run a homing program
that may mean that you have to home each axis in a sequence to ensure they don't crash
you should have...
|
Forum: LIVE PLC Questions And Answers
Yesterday, 11:17 AM
|
Replies: 23
Views: 798
|
Forum: LIVE PLC Questions And Answers
Yesterday, 11:07 AM
|
Replies: 5
Views: 143
I have done it many times over the years
Way...
I have done it many times over the years
Way back when the PLC2's were new PLc5's
Micro Logix, Compact Logix
Please keep in mind their are a lot of things to consider when doing it.
One thin...
|
Forum: LIVE PLC Questions And Answers
Yesterday, 10:01 AM
|
Replies: 5
Views: 143
That's doable it is done often
The first...
That's doable it is done often
The first thing to do is set a known home position and and on powerup drive it home
then it's a simple matter to keep track of the counts up-down from thee.
i...
|
Forum: LIVE PLC Questions And Answers
February 22nd, 2021, 10:05 PM
|
Replies: 20
Views: 1,002
|
Forum: LIVE PLC Questions And Answers
February 21st, 2021, 01:25 AM
|
Replies: 20
Views: 1,002
|
Forum: LIVE PLC Questions And Answers
February 18th, 2021, 09:03 PM
|
Replies: 20
Views: 1,002
what's the deal with just 3 turns
What about...
what's the deal with just 3 turns
What about using as MOP ( Motor Operated Pot )
I have install many 10 turn pots with a 3 digit display they worked very well I don't get a call for them much not...
|
Forum: LIVE PLC Questions And Answers
February 17th, 2021, 04:26 PM
|
Replies: 5
Views: 177
|
Forum: LIVE PLC Questions And Answers
February 17th, 2021, 04:03 PM
|
Replies: 5
Views: 177
I think the default setting are RS485 Modbus ...
I think the default setting are RS485 Modbus
Drive Wizard should be able to communicate with them
you do need to set the address for each drive
I some cranes some years ago using serial radio...
|
Forum: LIVE PLC Questions And Answers
February 13th, 2021, 01:13 AM
|
Replies: 22
Views: 1,169
I know that this may seem like an obvious...
I know that this may seem like an obvious question but I didn't see the answer in any of the post's Is their a check valve or a foot valve on the pump ?
If so is it working ?
What is the lift from...
|
Forum: LIVE PLC Questions And Answers
February 12th, 2021, 01:01 PM
|
Replies: 5
Views: 506
It called plug stopping it was popular like 40...
It called plug stopping it was popular like 40 years ago
it dose require a special contactor I believe it is still listed in the code
The contactor s rated for about twice what a jog contactor...
|
Forum: LIVE PLC Questions And Answers
February 12th, 2021, 10:50 AM
|
Replies: 22
Views: 1,169
|
Forum: LIVE PLC Questions And Answers
February 12th, 2021, 09:38 AM
|
Replies: 5
Views: 506
|
Forum: LIVE PLC Questions And Answers
February 12th, 2021, 09:34 AM
|
Replies: 1
Views: 223
|
Forum: LIVE PLC Questions And Answers
February 12th, 2021, 09:28 AM
|
Replies: 22
Views: 1,169
They should have gotten an alarm when the pump...
They should have gotten an alarm when the pump failed and the 2nd Backup pump should have started automatically and they should have gotten an email
It sounds like a good time to talk to them about...
|
Forum: LIVE PLC Questions And Answers
February 11th, 2021, 07:29 PM
|
Replies: 22
Views: 1,169
A Soft Start can never reverse the rotation /...
A Soft Start can never reverse the rotation / phase, most if not all are SCR's
on that size i would think they have a bypass contractor the power loss in the SCR's would be fairly high about 100...
|
Forum: LIVE PLC Questions And Answers
February 11th, 2021, 06:22 PM
|
Replies: 41
Views: 1,580
|
Forum: LIVE PLC Questions And Answers
February 11th, 2021, 06:14 PM
|
Replies: 22
Views: 1,169
it looks like you had a sudden phase reversal...
it looks like you had a sudden phase reversal while it was running
I have seen pump shafts snap with a phase reversal
I can see the motor winding taking the hit with those stresses
Dose the...
|
Forum: LIVE PLC Questions And Answers
February 11th, 2021, 03:35 PM
|
Replies: 3
Views: 378
|
Forum: LIVE PLC Questions And Answers
February 11th, 2021, 03:28 PM
|
Replies: 5
Views: 340
|
Forum: LIVE PLC Questions And Answers
January 29th, 2021, 07:46 AM
|
Replies: 2
Views: 413
|
Forum: LIVE PLC Questions And Answers
January 26th, 2021, 02:29 PM
|
Replies: 44
Views: 2,382
As far as I know there is no code standard for...
As far as I know there is no code standard for 24V systems but what I use and I find it works fairly well is
24- from the supply Blue with White stripe
25+ from the supply Blue with Black stripe...
|
Forum: LIVE PLC Questions And Answers
January 20th, 2021, 06:33 PM
|
Replies: 17
Views: 1,021
interesting that you think that a drive of any...
interesting that you think that a drive of any kind is a positioning drive by it's self
a servo drive has less capability then a VFD they all require a controller of some kind to do positioning ...
|
Forum: LIVE PLC Questions And Answers
January 20th, 2021, 03:02 PM
|
Replies: 17
Views: 1,021
there are a lot of thing not in the manual ...
there are a lot of thing not in the manual
Yaskawa has introduced the matrix U1000 full line regen
on cranes I use a rebranded A1000 Impulse Drive By Electromotive My normal stop on a hoist...
|
Forum: LIVE PLC Questions And Answers
January 20th, 2021, 12:16 PM
|
Replies: 17
Views: 1,021
Sparky
I can show you on a machine where I...
Sparky
I can show you on a machine where I replaced the the original servo drives with the A1000
in addition have have done countless crane hoisting applications with then where I sespend the...
|