You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 438
Search took 0.27 seconds.
Search: Posts Made By: Kataeb
Forum: LIVE PLC Questions And Answers November 7th, 2018, 08:51 AM
Replies: 2
Views: 87
Posted By Kataeb
Yes, i am considering a function FC that will set...

Yes, i am considering a function FC that will set all the happening bits, till the operator reset them.
Forum: LIVE PLC Questions And Answers November 7th, 2018, 06:28 AM
Replies: 2
Views: 87
Posted By Kataeb
save status of Interlok block FB75

Kindly, we are using Siemens Pcs7 v6 cfc blocks.
But, sometimes we are getting fast changing signals on the inputs of the Interlok block FB75 in the cfc, which are stopping a Motor block, without...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 09:57 AM
Replies: 0
Views: 55
Posted By Kataeb
need SQL Server 2000 for WinCC

Kindly, while trying to install Siemens Pcs7 Wincc v6, we got a message that "SQL Server 2000 Service Pack 3a" need to be installed from a CD. But somehow we don't have this CD. Is it possible to...
Forum: LIVE PLC Questions And Answers October 23rd, 2018, 02:49 AM
Replies: 4
Views: 275
Posted By Kataeb
Due to customer's requirements, i am trying to...

Due to customer's requirements, i am trying to reduce the cost by using G120 instead of S120 (about double price).
But my concern is that G120 might not work well with angular position loops.
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 03:00 AM
Replies: 4
Views: 275
Posted By Kataeb
simple Ac Drive with Advanced Motion Controller

Has anyone tried to use a simple Ac Drive with an Advanced Motion Controller? To do a low cost angular synchronization on machines (Rewinders) having big power Ac Motors? With a Position master...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 01:31 AM
Replies: 9
Views: 520
Posted By Kataeb
Main power supply is 3 x 380 vac , 50 hz ...

Main power supply is
3 x 380 vac , 50 hz
Thanks
Forum: LIVE PLC Questions And Answers October 19th, 2018, 10:35 AM
Replies: 9
Views: 520
Posted By Kataeb
Thank you for your reply. But, i am looking...

Thank you for your reply.

But, i am looking for some hints, on which motor Kw rating, is good enough for the Ac motors to replace the old Dc ones.
I know that usually we should increase the motor...
Forum: LIVE PLC Questions And Answers October 19th, 2018, 08:20 AM
Replies: 9
Views: 520
Posted By Kataeb
dc motors and drives > replace by ac ones

Kindly, we have the following dc motors (with their dc drives), running on a rewinding machine, in angular synchronization (small motors following the biggest one, in position control).
The customer...
Forum: LIVE PLC Questions And Answers October 12th, 2018, 06:27 AM
Replies: 2
Views: 282
Posted By Kataeb
solved: missing the extension ( .Aaaa_Bbbb ) in...

solved:
missing the extension ( .Aaaa_Bbbb ) in StatusProp and ValveProp of the Faceplate icon
Forum: LIVE PLC Questions And Answers October 10th, 2018, 12:18 PM
Replies: 2
Views: 282
Posted By Kataeb
why always green color of Valve block

We are using Valve block FB73 , with Siemens cfc v8.1 and wincc v7.3 .

But its Faceplate is always green , even if the valve is off .

How can we change that ?

Thank you
Forum: LIVE PLC Questions And Answers October 6th, 2018, 08:25 AM
Replies: 0
Views: 182
Posted By Kataeb
why cannot see small icons in valve faceplate (PCS7)

I cannot see the small icons in the valve faceplate FB73, so to click them for access to Maintenance view.

I am working on Siemens CFC v8.1 and WinCC v7.3, using PCS 7 Standard Library V71.

see...
Forum: LIVE PLC Questions And Answers October 6th, 2018, 02:03 AM
Replies: 7
Views: 409
Posted By Kataeb
Solved! We got a third sim card 10.28.76.4 and...

Solved!
We got a third sim card 10.28.76.4 and it worked fine with the sim card 10.28.76.3

Strangely the bad sim card 10.28.76.2 is only pinging well on mobile phones, it does not like ProSoft...
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 11:41 AM
Replies: 7
Views: 409
Posted By Kataeb
It is a ProSoft ICX35-HWC gateway. Yes, i can...

It is a ProSoft ICX35-HWC gateway.
Yes, i can ping anything from any laptop.
The only exception is no pinging of 10.28.76.3 through the gateways (remotely).
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 11:23 AM
Replies: 3
Views: 2,450
Posted By Kataeb
Kindly, how did you solve this problem " Export...

Kindly, how did you solve this problem
" Export and Import Tags from STEP7 to WinCC Explorer "
?
Thank you
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 11:25 AM
Replies: 7
Views: 409
Posted By Kataeb
I tried with Firewall off, same problem. The...

I tried with Firewall off, same problem.

The strange thing is that remote pinging of the other sim card (WAN 10.28.76.2) is always running, from any laptop, with any gateway!
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 02:45 AM
Replies: 7
Views: 409
Posted By Kataeb
no remote pinging for one wan address

Kindly, we have two laptops connected through two gateways with two m2m sim cards (https://en.wikipedia.org/wiki/Machine_to_machine), as follows.


Laptop1 (LAN 192.168.100.1)
to
Gateway1 (LAN...
Forum: LIVE PLC Questions And Answers September 24th, 2018, 02:18 AM
Replies: 2
Views: 197
Posted By Kataeb
Any ideas?

Any ideas?
Forum: LIVE PLC Questions And Answers September 21st, 2018, 09:39 AM
Replies: 2
Views: 197
Posted By Kataeb
create WinCC faceplates for CFC blocks

We have a Siemens Step7 multiproject, in which we are trying to add to the CFC program, some new Motor blocks and Valve blocks.
So, we need to create their corresponding WinCC faceplates.
Is there...
Forum: LIVE PLC Questions And Answers September 17th, 2018, 10:46 AM
Replies: 7
Views: 1,008
Posted By Kataeb
Ok. Actually, my problem is a bit different...

Ok.
Actually, my problem is a bit different from Shah's. But i was checking his, to find any similarities that might help.

My problem is the following.
After retrieving a PCS7 project on a new...
Forum: LIVE PLC Questions And Answers September 17th, 2018, 07:46 AM
Replies: 7
Views: 1,008
Posted By Kataeb
Kindly, what do you mean by "language "? Where is...

Kindly, what do you mean by "language "? Where is it? Thanks
Forum: LIVE PLC Questions And Answers September 17th, 2018, 04:13 AM
Replies: 7
Views: 1,008
Posted By Kataeb
Kindly, did you solve this issue? How? Thanks

Kindly, did you solve this issue? How? Thanks
Forum: LIVE PLC Questions And Answers September 11th, 2018, 09:54 AM
Replies: 0
Views: 100
Posted By Kataeb
display XYZ geographical coordinates in FactoryTalk

Can we display the XYZ geographical coordinates in FactoryTalk View SE ?
In which format ? suitable for Rockwell software.
Thanks
Forum: LIVE PLC Questions And Answers September 7th, 2018, 08:40 AM
Replies: 5
Views: 543
Posted By Kataeb
2 wire analog sensor power supply issues

An analog Transmitter (Sensor) with 2 wire and 4 to 20 mA output, is connected to an analog input module. The sensor requires an external 24 vdc power supply.
If any interference or fluctuation...
Forum: LIVE PLC Questions And Answers September 5th, 2018, 09:55 AM
Replies: 4
Views: 574
Posted By Kataeb
magic button to make a list of Rockwell softwares with versions

I did not find a magic button to make a list of all the Rockwell softwares with versions, which are installed on my laptop!
While with Siemens, we have the Installed Softwares option, which we can...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 02:42 AM
Replies: 4
Views: 496
Posted By Kataeb
Actually we are using this configuration: ...

Actually we are using this configuration:
Laptop >> local ICX35 >> 4G >> remote ICX35 >> PLC
Rockwell and ProSoft support mentioned that, in this case, we should access the remote ICX35...
Showing results 1 to 25 of 438

 