Search: Posts Made By: ceilingwalker
Forum: LIVE PLC Questions And Answers Yesterday, 01:08 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I swapped CPU's and now it's communicating. Could...

I swapped CPU's and now it's communicating. Could you please expand upon "it could be in the code" please? I am asking because sometimes when this VB .exe tries to load, it gets a Runtime Error 13...
Forum: LIVE PLC Questions And Answers Yesterday, 10:12 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I swapped coms modules and the problem still...

I swapped coms modules and the problem still exists at this one PLC but not the other so, that leaves the PLC connection between the card and the CPU.
Forum: LIVE PLC Questions And Answers Yesterday, 09:32 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Since both are identical, I shouldn't even need...

Since both are identical, I shouldn't even need to transfer anything, right, just do a verify?
Forum: LIVE PLC Questions And Answers Yesterday, 08:47 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Yes Sir, that's where I obtained that info in the...

Yes Sir, that's where I obtained that info in the screenshots above. I saved them whilst online with each.

How big of a deal is it to swap the serial cards from one PLC to the other. The other...
Forum: LIVE PLC Questions And Answers Yesterday, 07:53 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
This is a side-by-side comparison with the two...

This is a side-by-side comparison with the two PLC's. Everything is the same. Do these ports have a tendency to go bad? How could I test the port itself? No one has made any changes to these port...
Forum: LIVE PLC Questions And Answers February 26th, 2020, 05:25 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I am still having trouble getting the PC that...

I am still having trouble getting the PC that runs this executable to talk to the C200HX. I am using comm board B. As mentioned before, I have its sister robot working right next to it so, I compared...
Forum: LIVE PLC Questions And Answers February 26th, 2020, 05:20 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
No, this is the C200HX. After reading the books...

No, this is the C200HX. After reading the books you sent me for the compobus and devicenet modules, I figured out which registers exactly, they are using (thank you).

I still don't know what...
Forum: LIVE PLC Questions And Answers February 16th, 2020, 03:33 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
MrPLC had a word doc that explained it well...

MrPLC had a word doc that explained it well beyond the books definition. Also, I re-read about 6 posts before this, where you explained the # and the &.

Curious to see if this has any significant...
Forum: LIVE PLC Questions And Answers February 16th, 2020, 08:15 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
That's alright, I figured it out. There was an...

That's alright, I figured it out. There was an explanation on MrPLC that was perfect. Thank you
Forum: LIVE PLC Questions And Answers February 15th, 2020, 10:02 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I have figured them out by watching the machine...

I have figured them out by watching the machine run......Yes, it is now running, thanks to everyone's help here. :beerchug:

I have a question about the MOVD instruction, which I couldn't find an...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 09:42 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Yes Sir, I am looking at the actual block...

Yes Sir, I am looking at the actual block programs running in the MC. It doesn't give simple instructions like G01X1.0, it gives G01 then a sort of an indirect address that is changed with...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 05:02 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I have an M20 instruction that I can't find in...

I have an M20 instruction that I can't find in the book. I remember those were actually machine codes (spindle on, etc...).
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:31 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
AHAAAAA! Never mind the last post. I see now. The...

AHAAAAA! Never mind the last post. I see now. The MC421 is what determines what each G code means. I wish I had time to sit down and read this document you sent me before! It makes this way more...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:22 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I also noticed this is using G-code. That is very...

I also noticed this is using G-code. That is very new to me. I have written parts programs for CNC machinery but not on the controls end. I have looked up some of the G commands and have no idea what...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:06 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Another question please: Is there a way to look...

Another question please: Is there a way to look at I/O addressing in the MC421? I am looking for the command to tell the servo to turn on.
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:04 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
How does one decipher that?

How does one decipher that?
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 02:28 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Is there any way of knowing what area of memory...

Is there any way of knowing what area of memory this is pointing toward (CIO, D, etc....)?

53295
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 02:14 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Yes Sir, true Sigma7. Retro-fit the Sigma1 with...

Yes Sir, true Sigma7. Retro-fit the Sigma1 with the Sigma7.
Forum: LIVE PLC Questions And Answers February 1st, 2020, 02:56 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
I now have my new Yaskawa Sigma 7's installed,...

I now have my new Yaskawa Sigma 7's installed, jogging all 3 axes, learning the Sigmawin+ software....kid in a candy store sort of a thing. Anyway, I hope I don't sound to ridiculous with this...
Forum: LIVE PLC Questions And Answers January 29th, 2020, 10:22 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
No, I thought it would do that when I downloaded...

No, I thought it would do that when I downloaded the original program into the new CPU. I did try again though, and now there are no alarms. I think the issue was my RIO (RM201). Now it is blinking...
Forum: LIVE PLC Questions And Answers January 29th, 2020, 09:07 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
It was (as someone here mentioned), the CPU. I...

It was (as someone here mentioned), the CPU. I installed a new (used) one, loaded my program in and all my lights are back on. Now I get this alarm:

53254

I have confirmed in the I/O table is...
Forum: LIVE PLC Questions And Answers January 20th, 2020, 12:10 PM
Replies: 86
Views: 3,574
Posted By ceilingwalker
This wouldn't keep me from going online with the...

This wouldn't keep me from going online with the processor though, right? I noticed that all of the dip switches were off, in my original photo, before I touched anything. I am able to go online with...
Forum: LIVE PLC Questions And Answers January 20th, 2020, 09:08 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Red LED for error is on solid, power light is on...

Red LED for error is on solid, power light is on the PSU, that's all I have.
Forum: LIVE PLC Questions And Answers January 20th, 2020, 09:02 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
Since the electrician has been in this cabinet...

Since the electrician has been in this cabinet and won't admit to anything that he did (even though I now have a scalped wire on my 3-phase coming in that wasn't there before) I have to assume...
Forum: LIVE PLC Questions And Answers January 20th, 2020, 08:57 AM
Replies: 86
Views: 3,574
Posted By ceilingwalker
So, even if inputs are electronically connected,...

So, even if inputs are electronically connected, without the I/O table, LED's won't light? Most of my experience is AB and of course, they will light even if there is no project in the PLC.