Search: Posts Made By: bluebyu
Forum: LIVE PLC Questions And Answers Yesterday, 10:15 PM
Replies: 87
Views: 3,576
Posted By bluebyu
An example of code used with Omron a serial port,...

An example of code used with Omron a serial port, from MRPLC:

http://forums.mrplc.com/index.php?/files/file/288-txd-rxd-quickstart-programs/
Forum: LIVE PLC Questions And Answers Yesterday, 02:09 PM
Replies: 87
Views: 3,576
Posted By bluebyu
Hopefully others can jump in who may understand...

Hopefully others can jump in who may understand serial communications better than I....

Which com module is installed?
What are the led's showing for Com B?

As you have a custom built Personal...
Forum: LIVE PLC Questions And Answers Yesterday, 10:17 AM
Replies: 87
Views: 3,576
Posted By bluebyu
Or, it could be the code in the plc's

Or, it could be the code in the plc's
Forum: LIVE PLC Questions And Answers Yesterday, 09:20 AM
Replies: 87
Views: 3,576
Posted By bluebyu
Easy to swap cards. ensure to save actual...

Easy to swap cards.
ensure to save actual settings for ALL ports in each PLC.
Power down, swap, power up.
program mode, Load settings
switch to run or monitor.
Forum: LIVE PLC Questions And Answers Yesterday, 07:58 AM
Replies: 87
Views: 3,576
Posted By bluebyu
Just to make sure, Did you verify what's in the...

Just to make sure, Did you verify what's in the PLC and file by steps outlined in post 77 steps 2 and 3?
Forum: LIVE PLC Questions And Answers February 26th, 2020, 08:29 PM
Replies: 87
Views: 3,576
Posted By bluebyu
PC to C200HX comms

Com "B" is normally used for an extra com card installed in the CPU housing.

1. What com board part number is installed in both PLC's?

2. What are com port B settings in both? How are you...
Forum: LIVE PLC Questions And Answers February 17th, 2020, 07:09 AM
Replies: 87
Views: 3,576
Posted By bluebyu
Post 72; I was wondering what was the solution...

Post 72;
I was wondering what was the solution to the original issue preventing the system from running?

Post 73 above;
No, does NOT show I/O being used. The Cross Reference does.
It does...
Forum: LIVE PLC Questions And Answers February 16th, 2020, 10:23 AM
Replies: 87
Views: 3,576
Posted By bluebyu
Glad it has worked out!! What was the...

Glad it has worked out!!

What was the solution?
Forum: LIVE PLC Questions And Answers February 3rd, 2020, 10:45 AM
Replies: 87
Views: 3,576
Posted By bluebyu
If you wish, post some of your G code, perhaps...

If you wish, post some of your G code, perhaps some may be able to help.
Forum: LIVE PLC Questions And Answers February 3rd, 2020, 12:15 AM
Replies: 87
Views: 3,576
Posted By bluebyu
More info on M codes From Guide R062 ...

More info on M codes
From Guide R062
Stopover
A stopover outputs M code or D (interrupt) code without stopping
operation after feeding the axis by the specified distance during
operation. The...
Forum: LIVE PLC Questions And Answers February 3rd, 2020, 12:06 AM
Replies: 87
Views: 3,576
Posted By bluebyu
M codes, Omron manual W359 has many sections...

M codes, Omron manual W359 has many sections talking about M codes.

As I have not used them......looks like you use the M code, say M20 in a line with G code, in a task (MC card task 1 for this...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 05:20 PM
Replies: 87
Views: 3,576
Posted By bluebyu
Regarding M20 code. Have not used them. I...

Regarding M20 code. Have not used them.

I assume you are seeing these codes in the Motion Card? (Via Omron CX Motion Software)

From Manual W359, info on M codes is shown:
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:43 PM
Replies: 87
Views: 3,576
Posted By bluebyu
"How does one decipher that?" (post 57) The...

"How does one decipher that?" (post 57)

The number 188 stands by itself. This indicated the CIO memory area.
A constant (actual number) would have a # or & in the front.

Only confusing thing...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:21 PM
Replies: 87
Views: 3,576
Posted By bluebyu
"Another question please: Is there a way to look...

"Another question please: Is there a way to look at I/O addressing in the MC421? I am looking for the command to tell the servo to turn on."

Shown below, instructions from the PLC to the MC Card...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 03:12 PM
Replies: 87
Views: 3,576
Posted By bluebyu
Also just noticed, the data is coming from word...

Also just noticed, the data is coming from word 2018
--As your MC421 motion card is set to "Mach 0"--
Word 2018 and the next 29 words contains a lot of the data the MC card can share with the...
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 02:50 PM
Replies: 87
Views: 3,576
Posted By bluebyu
CIO word 188

CIO word 188
Forum: LIVE PLC Questions And Answers February 2nd, 2020, 09:21 AM
Replies: 87
Views: 3,576
Posted By bluebyu
"I now have my new Yaskawa Sigma 7's installed,...

"I now have my new Yaskawa Sigma 7's installed, jogging all 3 axes, learning the Sigmawin+ software....kid in a candy store sort of a thing. Anyway, I hope I don't sound to ridiculous with this...
Forum: LIVE PLC Questions And Answers January 29th, 2020, 03:22 PM
Replies: 87
Views: 3,576
Posted By bluebyu
Get online Ensure PLC is in Program On the...

Get online
Ensure PLC is in Program
On the left side, open on I/O table.
Right click, select "Create I/O Table"
Put PLC into run when ready
Forum: LIVE PLC Questions And Answers January 18th, 2020, 12:23 PM
Replies: 87
Views: 3,576
Posted By bluebyu
The correct cable from "Laptop" usb convertor to...

The correct cable from "Laptop" usb convertor to PLC RS232 port can be found here:
http://www.ia.omron.com/products/family/872/lineup.html
XW2Z-200S-CV
Forum: LIVE PLC Questions And Answers January 18th, 2020, 07:03 AM
Replies: 87
Views: 3,576
Posted By bluebyu
1. Power system down. Both the PA204 power...

1. Power system down. Both the PA204 power supply and the CS1G processor have a single phillips screw (each) holding them into the rack. (at the bottom)
Are they tight?
Loosen screws, pivot...
Forum: LIVE PLC Questions And Answers January 14th, 2020, 02:45 PM
Replies: 87
Views: 3,576
Posted By bluebyu
On the NT631C, are you connected to port A? ...

On the NT631C, are you connected to port A?
Using Cable XW2Z-S002?