Forum: LIVE PLC Questions And Answers June 12th, 2012, 06:59 PM
Replies: 7
Views: 2,151
Posted By darrenj
Asi bus....still current technology?

I have a small project coming up (20 or so pneumatic valves with feedback) the customer has expressed interest in Asi bus.
After searching the forums I see most questions were asked in 2009 - 2010. ...
Forum: LIVE PLC Questions And Answers September 26th, 2010, 08:54 AM
Replies: 2
Views: 1,006
Posted By darrenj
Direct Logix 405

Did a search at automation direct and all that came up was the ROHS compliance certificate.

Does any know if there is software still available?
is there a windows xp based software that will...
Forum: LIVE PLC Questions And Answers October 5th, 2009, 09:58 PM
Replies: 17
Views: 2,953
Posted By darrenj
compact logix has restrictions on how far from...

compact logix has restrictions on how far from the power supply you put you modules, as ken said a module with a 8 factor can go 8 slots from the supply,
Forum: LIVE PLC Questions And Answers October 5th, 2009, 05:55 PM
Replies: 10
Views: 2,602
Posted By darrenj
And the winner is Kamenges!! That looks...

And the winner is Kamenges!!

That looks like what was going on, i set the encoder to x2 and away it went, same counts every time i checked...

Now maybe i missed that in the manual but i dont...
Forum: LIVE PLC Questions And Answers October 5th, 2009, 04:52 AM
Replies: 10
Views: 2,602
Posted By darrenj
It is a TRD-360-RZVWD

It is a TRD-360-RZVWD
Forum: LIVE PLC Questions And Answers October 4th, 2009, 07:06 PM
Replies: 10
Views: 2,602
Posted By darrenj
Just as an update... went back today and...

Just as an update...

went back today and tried a couple of things,
First i used a bench top DC power supply to power the encoders, hooked up my power quality analizer, and saw a little...
Forum: LIVE PLC Questions And Answers October 3rd, 2009, 06:32 PM
Replies: 10
Views: 2,602
Posted By darrenj
1746 HSC with compact logix....

I have a 1746 HSC i am setting up on a machine, all is good, i am seeing counts, controlling the loads fine, however after a couple of min's i am eather losing counts or gaining.
Full scope
1 ab...
Forum: LIVE PLC Questions And Answers September 3rd, 2009, 02:29 PM
Replies: 1
Views: 2,521
Posted By darrenj
absolute encoder and compact logix...

I have an automation direct absolute encoder and need to connect it to a compact logix processor, I see the HSC will not support absolute so i see 2 options,
SSI card
or
Wire the encoder to a fast...
Forum: LIVE PLC Questions And Answers June 1st, 2009, 06:51 AM
Replies: 0
Views: 1,010
Posted By darrenj
Control logix bootp

I have an existing Control logix setup, 2 racks communicating over ethernet. recently on a power cycle the modules start up in Bootp mode. This hasnt happened before, both modules are supposed to...
Forum: LIVE PLC Questions And Answers October 22nd, 2008, 09:51 PM
Replies: 1
Views: 885
Posted By darrenj
Sorry...momentary brain ****... Instead of...

Sorry...momentary brain ****...

Instead of scaling i just put in 4095 as the max unit and use the raw values.....
Forum: LIVE PLC Questions And Answers October 22nd, 2008, 09:11 PM
Replies: 1
Views: 885
Posted By darrenj
Modicon PID2..negitive low engineer range

OK..so i have a PID2 block controlling a valve, this valve opens and closes to keep water coming out of a cooler at 2 deg c..

I have a 0-100 deg RTD,

In the PID block at 4x +12 i have to...
Forum: LIVE PLC Questions And Answers September 12th, 2008, 09:36 PM
Replies: 4
Views: 2,270
Posted By darrenj
Most THHN is also MTW certified...you have to...

Most THHN is also MTW certified...you have to pull the specs..
Forum: LIVE PLC Questions And Answers September 6th, 2008, 07:52 PM
Replies: 19
Views: 2,974
Posted By darrenj
Very Nice picture....but you cant be in...

Very Nice picture....but you cant be in canada...dont we all live in igloos or something?????? :)


You got my vote

D
Forum: LIVE PLC Questions And Answers August 3rd, 2008, 07:26 PM
Replies: 28
Views: 2,854
Posted By darrenj
LOL...up here its like i would have a...

LOL...up here its like i would have a choice...you get female only gyms..but very few and far between male only...Plus i like to live on the dangerous side!! I would accept the hazard!

and BTW..i...
Forum: LIVE PLC Questions And Answers August 2nd, 2008, 09:31 PM
Replies: 153
Views: 13,803
Posted By darrenj
I grew up in England..i have the IRA to thank for...

I grew up in England..i have the IRA to thank for my views...I do not remember Fire drills in my school years..just Bomb drills....
Forum: LIVE PLC Questions And Answers August 2nd, 2008, 08:16 PM
Replies: 28
Views: 2,854
Posted By darrenj
Its funny..but i dont think about it... I run...

Its funny..but i dont think about it...
I run on 5-6 hours sleep...never thought about joining a Gym..i eat out more ofter than i eat at home..but i am still 5'10 and 140 lbs..last pysical my doc...
Forum: LIVE PLC Questions And Answers August 2nd, 2008, 08:08 PM
Replies: 153
Views: 13,803
Posted By darrenj
Finaly..people are starting to see the truth......

Finaly..people are starting to see the truth... Homeland security isn't about protecting you...its about the illusion of protecting you.. As everyone here has said there are a thousand ways around...
Forum: LIVE PLC Questions And Answers July 13th, 2008, 12:46 AM
Replies: 16
Views: 2,705
Posted By darrenj
hmmm as executive director of growth...do i get a...

hmmm as executive director of growth...do i get a cut!!
Forum: LIVE PLC Questions And Answers July 12th, 2008, 08:13 PM
Replies: 2
Views: 4,502
Posted By darrenj
LMAO...sorry..your gonna be SOL on this one..The...

LMAO...sorry..your gonna be SOL on this one..The GE software for this is restricted to Fire alarm techs who work with GE..I wont even go anywhere near the liablitly aspect if you tried to program the...
Forum: LIVE PLC Questions And Answers July 12th, 2008, 08:08 PM
Replies: 16
Views: 2,705
Posted By darrenj
Congrats David..and i mean that 100% from the...

Congrats David..and i mean that 100% from the gut.... Hope it turns out great for you..
Forum: LIVE PLC Questions And Answers July 4th, 2008, 09:00 PM
Replies: 3
Views: 1,696
Posted By darrenj
compact logix and scan SOLVE!!..Not scan time

Hey all...i know there are a thousand threads relating to how the logix series scan time works..my question is..how does it solve...after the scan..when its updating..does it update...
Forum: LIVE PLC Questions And Answers June 26th, 2008, 10:58 PM
Replies: 14
Views: 1,800
Posted By darrenj
Im suprised controlled..most plants i come across...

Im suprised controlled..most plants i come across now demand at least 3 and most are asking for 5.... And the $900 is dirt cheap!..mind you i am listed as an electrical contractor...trust me i would...
Forum: LIVE PLC Questions And Answers June 16th, 2008, 04:38 PM
Replies: 6
Views: 3,367
Posted By darrenj
lol...i am a moron! the perodic task was...

lol...i am a moron!

the perodic task was not enabled....
Forum: LIVE PLC Questions And Answers June 14th, 2008, 10:50 PM
Replies: 6
Views: 3,367
Posted By darrenj
Thanks Mickey..came across that note before...it...

Thanks Mickey..came across that note before...it seems no matter what i do or in what i order i do it in the loop will not "go"...

i have the exact same setup in control logix and it works...
Forum: LIVE PLC Questions And Answers June 14th, 2008, 08:41 PM
Replies: 6
Views: 3,367
Posted By darrenj
Compact logix PID problems

I have a compact logix processor and i am trying to get a PID instruction to work...

I set up all the relevant data..CV...PV etc etc..i set my loop time to (at the moment whatever!)...i then...
Showing results 1 to 25 of 500

 