Forum: LIVE PLC Questions And Answers August 16th, 2017, 07:30 PM
Replies: 20
Views: 1,354
Posted By Ravioli
I can't blame him. I've felt like doing that to...

I can't blame him. I've felt like doing that to PVP many times.

The best is operators trying to explain away a shattered CRT, behind a shattered plastic cover, when it isn't even touch screen.
Forum: LIVE PLC Questions And Answers August 16th, 2017, 06:56 PM
Replies: 61
Views: 4,958
Posted By Ravioli
Saw a thread complaining about Rockwell software,...

Saw a thread complaining about Rockwell software, expecting to see comments about FactoryTalk (View), wasn't disappointed.

Aside from the confusing name (What people call "Factory Talk" is...
Forum: LIVE PLC Questions And Answers August 9th, 2017, 11:59 PM
Replies: 72
Views: 3,936
Posted By Ravioli
I'm amazed at the price difference between a...

I'm amazed at the price difference between a ControlLogix 2MB 1756-L71, and a 32MB 1756-L75. I doubt the incremental cost of 30MB memory is close to the 4x price tag.
Forum: LIVE PLC Questions And Answers June 16th, 2017, 06:03 PM
Replies: 14
Views: 747
Posted By Ravioli
Excellent thought JaxGTO on Block transfers. ...

Excellent thought JaxGTO on Block transfers.

DHRIO has a limit of 16 Block Transfer buffers per remote I/O channel, meaning you have to be careful with what you're firing at once, and you...
Forum: LIVE PLC Questions And Answers June 16th, 2017, 04:03 PM
Replies: 14
Views: 747
Posted By Ravioli
PLC5 does seem to be a lot more robust than CLGX...

PLC5 does seem to be a lot more robust than CLGX cards on RIO and DH+.

It's poorly documented (not consistent), but I've seen Rockwell recommend 82 Ohm resistors, even at 56K and 115K IF all...
Forum: LIVE PLC Questions And Answers June 16th, 2017, 03:12 PM
Replies: 7
Views: 425
Posted By Ravioli
dmargineau: Side cars can do CIP E/IP messaging...

dmargineau: Side cars can do CIP E/IP messaging if the card, and the processor are the right revision. Rockwell AnswerID 7983, 61405,66899 have more details.
Processor has to be minimum Series E,...
Forum: LIVE PLC Questions And Answers June 6th, 2017, 02:22 PM
Replies: 33
Views: 3,627
Posted By Ravioli
Emulate 5000 is included with Studio 5000...

Emulate 5000 is included with Studio 5000 Professional license (9324-RLD700NXENE), along with RSNetworx licenses.

I'm thinking 9310-WED200ENE is the right standalone license.
Forum: LIVE PLC Questions And Answers May 20th, 2017, 08:57 PM
Replies: 16
Views: 903
Posted By Ravioli
Mickey, I'm not the OP, just giving a...

Mickey,

I'm not the OP, just giving a suggestion. He has a U2DHP mini-din, and possibly a PCMK with a mini-din, so he must have a device (like a PLC5 Enhanced) to plug it into. Even if one has to...
Forum: LIVE PLC Questions And Answers May 20th, 2017, 03:44 PM
Replies: 16
Views: 903
Posted By Ravioli
I've used a powered off PLC-5 Enhanced processor...

I've used a powered off PLC-5 Enhanced processor as an adapter. On channel 1A, connect U2DHP mini-din. To the linked Channel 1A pheonix connector run blue hose to the pheonix connector of the...
Forum: LIVE PLC Questions And Answers May 17th, 2017, 02:22 AM
Replies: 6
Views: 604
Posted By Ravioli
Windows won't let you format FAT32 beyond 32GB,...

Windows won't let you format FAT32 beyond 32GB, though Third party tools (http://www.techrepublic.com/blog/windows-and-office/format-fat32-drives-beyond-32gb-limit/) can help.

exFAT would be a...
Forum: LIVE PLC Questions And Answers May 9th, 2017, 05:40 PM
Replies: 9
Views: 938
Posted By Ravioli
Try to be consistent. If the operators use other...

Try to be consistent. If the operators use other HMIs, try to make it intuitively familiar. But at the same time, don't limit yourself. I've seen retrofits where the new HMI tries to painstakingly...
Forum: LIVE PLC Questions And Answers May 9th, 2017, 04:55 PM
Replies: 5
Views: 588
Posted By Ravioli
Interesting. A lot of our new PCs as given by IT...

Interesting. A lot of our new PCs as given by IT have the DPI setting increased to 125% or higher for some reason. I was annoyed to see this carry through to a VM guest.

The only glitch I've run...
Forum: LIVE PLC Questions And Answers May 3rd, 2017, 05:25 PM
Replies: 3
Views: 312
Posted By Ravioli
"77 Data size expected by the device does not ...

"77 Data size expected by the device does not
match scan list entry.
Reconfigure your module for the correct
transmit and receive data sizes"

In RSNetworx: Do a complete upload of the network....
Forum: LIVE PLC Questions And Answers May 1st, 2017, 05:08 PM
Replies: 8
Views: 354
Posted By Ravioli
Others mentioned the details (1756-DHRIO, Prosoft...

Others mentioned the details (1756-DHRIO, Prosoft gateway, etc).

Once you have that, you can add this gateway as a node on your DH+ network (DH+ supports up to 64 nodes). As long as you have a...
Forum: LIVE PLC Questions And Answers April 27th, 2017, 09:24 PM
Replies: 10
Views: 544
Posted By Ravioli
When added to RSLogix, 1756-DHRIO lists:...

When added to RSLogix, 1756-DHRIO lists: "1747-ASB", "1771-ASB", "1794-ASB", and "RIO-ADAPTER" (Generic) as available adapters. Almost anything should work given the availability of the generic...
Forum: LIVE PLC Questions And Answers April 27th, 2017, 08:38 PM
Replies: 22
Views: 1,108
Posted By Ravioli
2711P-RN6 is still listed as an active product,...

2711P-RN6 is still listed as an active product, and will work with Panelview Plus 6 series for DH+ access. I believe it will not work with PV+7 or PV 5500. A Panelview Plus DH+ application should...
Forum: LIVE PLC Questions And Answers April 22nd, 2017, 11:25 AM
Replies: 20
Views: 1,358
Posted By Ravioli
Testdisk...

Testdisk (http://www.cgsecurity.org/wiki/TestDisk) is available for Windows as well. I have used Testdisk when partition entries get corrupt.

I have also used ddrescue on Linux when trying to...
Forum: LIVE PLC Questions And Answers April 21st, 2017, 05:14 PM
Replies: 3
Views: 465
Posted By Ravioli
It gets very complicated, but a Windows Data...

It gets very complicated, but a Windows Data Center Server licence will allow an unlimited number of VM guests running Windows Server on that hardware, on a per processor basis (Server 2012R2) or per...
Forum: LIVE PLC Questions And Answers April 20th, 2017, 08:00 PM
Replies: 12
Views: 414
Posted By Ravioli
Changing the computer name can screw up factory...

Changing the computer name can screw up factory talk directory.

Make sure your Windows Administrator account has a password.

Open "Factory Talk Administration Console" File-Log on and select...
Forum: LIVE PLC Questions And Answers April 20th, 2017, 07:32 PM
Replies: 25
Views: 749
Posted By Ravioli
I've used Drive Executive to connect online,...

I've used Drive Executive to connect online, upload and download with 525 drives. If the AOP has been installed, or a new enough version of Logix is used that includes the AOP (you can tell if the...
Forum: LIVE PLC Questions And Answers April 20th, 2017, 07:05 PM
Replies: 80
Views: 4,639
Posted By Ravioli
It doesn't matter WHERE the tag is set, when you...

It doesn't matter WHERE the tag is set, when you hover over a tag in an ST program in RSLogix 5000 v 20 (can't speak to newer), the tooltip does not update after it first appears.

Observe a TONR...
Forum: LIVE PLC Questions And Answers April 20th, 2017, 03:26 PM
Replies: 80
Views: 4,639
Posted By Ravioli
I don't know about in newer versions, but in...

I don't know about in newer versions, but in Version 20, when the tooltip pops up it will show the value at that time, but not after that. I just checked and verified this was the case by hovering...
Forum: LIVE PLC Questions And Answers April 20th, 2017, 04:24 AM
Replies: 80
Views: 4,639
Posted By Ravioli
Colorization would be fantastic if added to...

Colorization would be fantastic if added to RSLogix, to at least show the value of BOOLs. Right now hovering over a tag will tell you at that time what the value is, but doesn't update unless you...
Forum: LIVE PLC Questions And Answers April 16th, 2017, 07:02 PM
Replies: 21
Views: 1,102
Posted By Ravioli
Overall I'm a fan of AssetCentre, but it's not...

Overall I'm a fan of AssetCentre, but it's not without it's limitations. Certainly much better than just a shared network folder. We have good compliance of usage by automation engineers, but shift...
Forum: LIVE PLC Questions And Answers November 3rd, 2016, 05:16 PM
Replies: 5
Views: 918
Posted By Ravioli
Thanks Ken. I made an educated guess earlier...

Thanks Ken.

I made an educated guess earlier today to select connected and cached.

Would this be a fair statement on how messages should be configured based on how often they are sent?

Most...