Forum: LIVE PLC Questions And Answers October 26th, 2018, 09:31 AM
Replies: 22
Views: 1,138
Posted By Rob S.
So you guys think by just using shielded Ethernet...

So you guys think by just using shielded Ethernet cables I should be good running along side the 480 vac wires ?

Thanks for all your input and help .
Forum: LIVE PLC Questions And Answers October 25th, 2018, 02:45 PM
Replies: 22
Views: 1,138
Posted By Rob S.
Maybe I missed something, what is that extra port...

Maybe I missed something, what is that extra port ? I think it says DS 1.
Forum: LIVE PLC Questions And Answers October 25th, 2018, 02:08 PM
Replies: 22
Views: 1,138
Posted By Rob S.
Tight on space in panel.How does Cat6 Enet cable and 480 vac play together ?

Good Afternoon,

I'm building a 480 volt control panel with PowerFlex 525 drives . These drives are Ethernet. I have a mixture of Cat 6 cables with 480 vac wires going to the
PowerFlex 525...
Forum: LIVE PLC Questions And Answers September 11th, 2018, 04:32 PM
Replies: 2
Views: 286
Posted By Rob S.
Connected Components Workbench - Could you tell me what this filr is .ccwarc ?

Good Afternoon ,

I was emailed this file with this extension .ccwarc from a machine manufacture. I know it is related to CCW , but I can not open it , and it does not recognize it . Could you...
Forum: LIVE PLC Questions And Answers September 3rd, 2018, 02:49 PM
Replies: 2
Views: 262
Posted By Rob S.
Thanks Sir . This machine and it's Kinetix 6000...

Thanks Sir . This machine and it's Kinetix 6000 units have been the same application for almost 8 years . Yes Sir , I did read that tech note . Could it be power related ? On all the property tags I...
Forum: LIVE PLC Questions And Answers September 3rd, 2018, 01:42 PM
Replies: 2
Views: 262
Posted By Rob S.
Kinetix 6000 E 81 Fault on all drives(16)at once . What could be the cause ?

Good Afternoon ,

I have a strange problem with 2 banks of Kinetix 6000 servo drives . The machine is running along for about 10 minutes , and the machine stops and I get E 81 Faults across all...
Forum: LIVE PLC Questions And Answers August 14th, 2018, 08:37 AM
Replies: 3
Views: 210
Posted By Rob S.
Thanks

Thanks
Forum: LIVE PLC Questions And Answers August 14th, 2018, 07:43 AM
Replies: 3
Views: 210
Posted By Rob S.
ControlLogix - Logix 5582ES Safety CPU. Any special edition of RS Logix 5000 needed ?

Good Morning ,

We have some new machinery coming in with a ControlLogix 5582ES Safety CPU . I would like to update our software before the equipment arrives .
Is there any special edition...
Forum: LIVE PLC Questions And Answers August 13th, 2018, 09:51 AM
Replies: 3
Views: 292
Posted By Rob S.
Great . Thanks so much .

Great . Thanks so much .
Forum: LIVE PLC Questions And Answers August 13th, 2018, 09:12 AM
Replies: 3
Views: 292
Posted By Rob S.
FT ME / Piloted List Selector - Having a partial caption description with a variable

Good Morning ,

I'm using FactoryTalk / ME and I have a Piloted List Selector that I have the recipes that the operator chooses from. On another screen I have where the operator can change the...
Forum: LIVE PLC Questions And Answers August 8th, 2018, 11:31 AM
Replies: 3
Views: 279
Posted By Rob S.
Using a CompactLogix L33ER - How many Controller and Program Tags can you have ?

Good Morning ,

I'm using a CompactLogix L33ER CPU . A number of my tags are going to be REAL. I looked in the processor manual , and could not find anything clear about the number of tags...
Forum: LIVE PLC Questions And Answers July 13th, 2018, 09:40 AM
Replies: 2
Views: 336
Posted By Rob S.
Thanks . Sounds like a plan.

Thanks . Sounds like a plan.
Forum: LIVE PLC Questions And Answers July 13th, 2018, 06:12 AM
Replies: 2
Views: 336
Posted By Rob S.
Testing ControlLogix and CompactLogix CPU's without I/O

Good Morning ,

We have a shelf of ControlLogix and Compactlogix CPU's . I would like to test these and also use these for training . Can you download a program to them , same processor in the...
Forum: LIVE PLC Questions And Answers June 28th, 2018, 06:50 PM
Replies: 8
Views: 603
Posted By Rob S.
Thanks for your wisdom , gentlemen. So you...

Thanks for your wisdom , gentlemen.

So you are saying that each foot per minute would be 1.304 HZ ?

"Take the operator's entry in Feet/Minute, multiply by (60/46 =) 1.304, and that will get you...
Forum: LIVE PLC Questions And Answers June 28th, 2018, 03:46 PM
Replies: 8
Views: 603
Posted By Rob S.
How would you take Foot Per Minute and work that back to needed frequency for a drive

Good Afternoon ,

I'm upgrading a machine , and all the conveyor speeds are in Foot Per Minute. That is what the operator will select on their screen. How would I take the Foot Per Minute of a...
Forum: LIVE PLC Questions And Answers June 24th, 2018, 10:56 AM
Replies: 10
Views: 659
Posted By Rob S.
Possibly . That is why I want to pick up the...

Possibly . That is why I want to pick up the actual belt movement.

Thanks
Forum: LIVE PLC Questions And Answers June 24th, 2018, 08:48 AM
Replies: 10
Views: 659
Posted By Rob S.
Looking for a Tachometer ( 4-20 ma ) to sense FPM on a cloth belt .

Good Morning ,

Do you guys know of any tachometers ( 4-20 ma ) with a fragile soft wheel to sense FPM on a cloth belt ? I was thinking of using a weighted bracket and the weight of the...
Forum: LIVE PLC Questions And Answers May 19th, 2018, 10:06 PM
Replies: 1
Views: 376
Posted By Rob S.
Panelview Plus 7 - Can you play live video from a camera ?

Good Evening ,

We have a machine I'm going to be doing an upgrade to. I would like to use the Panelview Plus 7 - Performance . We have some blind spots on this machine , and I would like to...
Forum: LIVE PLC Questions And Answers May 9th, 2018, 02:07 PM
Replies: 5
Views: 822
Posted By Rob S.
Panelview Plus 6 vs Panelview Plus 7- .MER's ran on 6's will run on 7's, correct ?

Good Afternoon ,

Took notice the price really jumped on Panelview Plus 6's . A .MER runtime that was running on a Panelview Plus 6 will run seamlessly on a Panelview Plus 7 , correct ?
...
Forum: LIVE PLC Questions And Answers January 23rd, 2018, 02:07 PM
Replies: 9
Views: 663
Posted By Rob S.
They are all good points , and I will look into...

They are all good points , and I will look into them. No , nothing has been changed . I will check all that you suggested .

Thanks so much.
Forum: LIVE PLC Questions And Answers January 23rd, 2018, 03:49 AM
Replies: 9
Views: 663
Posted By Rob S.
It has been powered down numerous times .

It has been powered down numerous times .
Forum: LIVE PLC Questions And Answers January 22nd, 2018, 06:15 PM
Replies: 9
Views: 663
Posted By Rob S.
No Sir . Nobody replaced the drive . The only...

No Sir . Nobody replaced the drive . The only difference from Friday night till
This morning , was power was shutdown on the panel .

Thanks for your input .
Forum: LIVE PLC Questions And Answers January 22nd, 2018, 08:55 AM
Replies: 9
Views: 663
Posted By Rob S.
After power up of CompactLogix Yellow Triangle on PowerFlex 525

Good Morning ,

We have been running a machine , PLC and PowerFlex 525 for over a year. For some unknown reason , I have a Yellow Triangle on the Ethernet PowerFlex 525 tree , with a ( Code...
Forum: LIVE PLC Questions And Answers January 13th, 2018, 10:09 AM
Replies: 13
Views: 1,273
Posted By Rob S.
Thanks so much for the helpful information. I...

Thanks so much for the helpful information. I need to study up more . If I did more programming it would probably sink in more.
Forum: LIVE PLC Questions And Answers December 29th, 2017, 07:53 PM
Replies: 1
Views: 497
Posted By Rob S.
Converting a Panelview Micro 300 application to a Panelview 800.

Good Evening ,

We have an obsolete Panelview 300 Micro that is "toast" . Our electrician ordered a Panelview 800. Apparently it sounds like the Panelview 800 is its replacement . Are you...