You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 0.41 seconds.
Search: Posts Made By: Geospark
Forum: LIVE PLC Questions And Answers November 29th, 2019, 07:56 PM
Replies: 4
Views: 432
Posted By Geospark
Just to add... As Logix 5000 projects...

Just to add...



As Logix 5000 projects may contain multiple Programs within the default Main Task, or indeed multiple Tasks with multiple Programs, there may potentially be many Programs within...
Forum: LIVE PLC Questions And Answers November 27th, 2019, 06:02 PM
Replies: 11
Views: 417
Posted By Geospark
Glad you got the Gateway address sorted Steve,...

Glad you got the Gateway address sorted Steve, but just to answer your earlier query. Once everything is setup and working correctly, as appears to be the case for you now, you should definitely be...
Forum: LIVE PLC Questions And Answers November 25th, 2019, 12:05 PM
Replies: 2
Views: 318
Posted By Geospark
Let's make this Redundantly clear...

Hi,

I had read your post the other day but said I'd come back to it when I had more time...

"ControlFLASH Plus is a more feature-packed version of ControlFLASH, enabling you to flash one or...
Forum: LIVE PLC Questions And Answers November 21st, 2019, 05:18 PM
Replies: 9
Views: 645
Posted By Geospark
A routine assumption...

Just an observation on the possibility of the routine not being scanned...

According to Rob...



While it would also be useful to have that further qualified, it would be my assumption that,...
Forum: LIVE PLC Questions And Answers November 21st, 2019, 12:15 PM
Replies: 9
Views: 645
Posted By Geospark
Some routine info...

Just a passing "heads up"...





There is no "Lad 2" in Logix 5000 controller projects.

There is the default "MainRoutine" under the default "MainProgram", under the default "MainTask"....
Forum: LIVE PLC Questions And Answers November 21st, 2019, 11:40 AM
Replies: 11
Views: 383
Posted By Geospark
Spot the difference?...

Hi,

Just be careful with that sample reference for a 1761-L32BWA controller. The wiring diagram is correct but the wire descriptions are a bit mixed up for the lower diagram on Page 2-3.

If...
Forum: LIVE PLC Questions And Answers November 19th, 2019, 11:49 AM
Replies: 4
Views: 245
Posted By Geospark
You probably need to set the "Point Mode" for the...

You probably need to set the "Point Mode" for the input points in the software?
Without this set the inputs will be inactive.

Go the the module properties for the 1734-IB8S and then to the...
Forum: LIVE PLC Questions And Answers November 19th, 2019, 11:29 AM
Replies: 22
Views: 1,441
Posted By Geospark
Hi Norm, I'm going to take your advice here...

Hi Norm,

I'm going to take your advice here and, for the most part, ignore the traditional wiring diagrams you provided, as they are not Safety circuits, at all, and in my opinion we really...
Forum: LIVE PLC Questions And Answers November 19th, 2019, 07:15 AM
Replies: 7
Views: 551
Posted By Geospark
Just to help you understand a little better...

Welcome to the Forum!

It sounds like they are trying to sell you a "Toolkit", while it sounds like the last thing you require is a "Toolkit"?...



If it's unlikely you will have to work on...
Forum: LIVE PLC Questions And Answers November 18th, 2019, 12:29 PM
Replies: 34
Views: 3,359
Posted By Geospark
"Version" of events...

OK, thanks for the heads up, but that is strange? By my reckoning before I had posted, that should not have been possible?

And to be fair to Rockwell, some of what I posted is part my info. But I...
Forum: LIVE PLC Questions And Answers November 17th, 2019, 06:14 PM
Replies: 3
Views: 428
Posted By Geospark
Octal Optics...

A suggestion, if I may?...

It may not matter, especially if you are just making a general enquiry, but mentioning the actual module's catalog number might help better jog some people's memories,...
Forum: LIVE PLC Questions And Answers November 17th, 2019, 07:16 AM
Replies: 1
Views: 341
Posted By Geospark
Route Causes..

Hi Ken,

I read your post the other day and thought, good on you. Even if our friend dissapears, it's always good to "NAT" these "Private" requests out to the wider "Public" so as to discuss and...
Forum: LIVE PLC Questions And Answers November 16th, 2019, 07:06 AM
Replies: 14
Views: 1,060
Posted By Geospark
You may also read the following previous...

You may also read the following previous information I provided for another member, and also the linked thread within the first post, where I detailed the makup and options we might have when working...
Forum: LIVE PLC Questions And Answers November 16th, 2019, 05:44 AM
Replies: 34
Views: 3,359
Posted By Geospark
And thank you, my friend. That is excellent...

And thank you, my friend.

That is excellent news and adds valuable feedback on the possibility of it working in certain Windows 10 Editions.

I would reiterate, and in line with jimtech67's...
Forum: LIVE PLC Questions And Answers November 16th, 2019, 03:59 AM
Replies: 25
Views: 9,789
Posted By Geospark
Hi grompy, Thank you for your positive...

Hi grompy,

Thank you for your positive feedback and a very warm "Welcome to the Forum!" to you :site:
Forum: LIVE PLC Questions And Answers November 15th, 2019, 03:33 PM
Replies: 6
Views: 450
Posted By Geospark
Just to officially confirm this... 775825...

Just to officially confirm this...

775825 (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/775825) - Connected Cached MSG results in a Major Non-Recoverable Fault (MNRF) on 5580...
Forum: LIVE PLC Questions And Answers November 15th, 2019, 12:14 PM
Replies: 34
Views: 3,359
Posted By Geospark
CaspianSage, I can say here with certainty...

CaspianSage,

I can say here with certainty that I am not mistaken, simply because I was successful in doing what I outlined, and what the technote I linked outlines. That is, I used EVMOVECF, and...
Forum: LIVE PLC Questions And Answers November 13th, 2019, 10:02 AM
Replies: 11
Views: 857
Posted By Geospark
If you can access the following technote... ...

If you can access the following technote...

1072844 (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1072844) - RSLogix 5000: Fatal Error 0xe0434F4d When Opening Module Properties...
Forum: LIVE PLC Questions And Answers November 13th, 2019, 09:43 AM
Replies: 3
Views: 267
Posted By Geospark
Another consideration from memory...

...Assuming no hardware issue, and assuming no code that "initializes" the array, does the "CompactLogix" have a CompactFlash memory card (older model) or an SD card (newer model)?

A memory card...
Forum: LIVE PLC Questions And Answers November 13th, 2019, 06:12 AM
Replies: 2
Views: 237
Posted By Geospark
Welcome, welcome. For the MicroLogix 1000,...

Welcome, welcome.

For the MicroLogix 1000, one other interesting(?) detail I always like to point out is the dimensional difference between the AC and DC voltage supply models...

The...
Forum: LIVE PLC Questions And Answers November 12th, 2019, 05:51 PM
Replies: 7
Views: 329
Posted By Geospark
Ah, very good. My Sister-in-law is from the...

Ah, very good. My Sister-in-law is from the Dominican Republic, and works for Amazon. She lived and worked in Brazil for a few years before moving to Germany for another few years and then on to...
Forum: LIVE PLC Questions And Answers November 12th, 2019, 03:26 PM
Replies: 7
Views: 329
Posted By Geospark
You're correcting me a lot this weather, eh...

You're correcting me a lot this weather, eh Patrick? :wait:

I do know that though. I have four siblings that live in Spain so I'm reasonably proficient in Spanish, but not Portuguese. So I wrote...
Forum: LIVE PLC Questions And Answers November 12th, 2019, 10:07 AM
Replies: 7
Views: 329
Posted By Geospark
Going on the assumption that there is a license...

Going on the assumption that there is a license available and you are still getting this error, there are many possible reasons for this error message...

If you have TechConnect...

En...
Forum: LIVE PLC Questions And Answers November 12th, 2019, 09:42 AM
Replies: 4
Views: 202
Posted By Geospark
Please see the following technotes... 61335...

Please see the following technotes...

61335 (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/61335) - FactoryTalk View SE: When importing a HMI server into a Networked...
Forum: LIVE PLC Questions And Answers November 12th, 2019, 09:24 AM
Replies: 4
Views: 229
Posted By Geospark
Oh, good man! I have that User Manual open here...

Oh, good man! I have that User Manual open here since earlier but I forgot to directly link to it in my first post, although it is also available via the links we've provided.

The older MVI56-MCM...
Showing results 1 to 25 of 500

 