Search: Posts Made By: andepand
Forum: LIVE PLC Questions And Answers Yesterday, 05:35 PM
Replies: 2
Views: 218
Posted By andepand
Thanks man, I was looking For settings in the...

Thanks man, I was looking For settings in the event/alarm screens. It didnít occur to me that I can change the font in the actual event list.

Thanks again, case closed.
Forum: LIVE PLC Questions And Answers December 8th, 2019, 03:32 AM
Replies: 2
Views: 218
Posted By andepand
Omron NB event screen

Hi.

For a project Iím programming a 10 inch Omron NB hmi. Now, creating an event or alarm screen is no problem, however all event related screens have the same small font.

I want to decide...
Forum: LIVE PLC Questions And Answers October 22nd, 2019, 01:43 AM
Replies: 18
Views: 1,003
Posted By andepand
I'm using loops mainly for stuff like the script...

I'm using loops mainly for stuff like the script below. So, since I'm hardly a programming specialist, how would this translate to a non loop or non ST program?

FOR Loop1:= 0 TO 31 DO (*Move...
Forum: LIVE PLC Questions And Answers October 21st, 2019, 06:57 PM
Replies: 18
Views: 1,003
Posted By andepand
edit, tried to write some example code but that...

edit, tried to write some example code but that doesnít really work in this editor
Forum: LIVE PLC Questions And Answers October 21st, 2019, 05:46 PM
Replies: 18
Views: 1,003
Posted By andepand
In case of electricians troubleshooting the plc,...

In case of electricians troubleshooting the plc, that is a valid point.

Here in Holland, and in my experience in Germany also, electricians pretty much stay away from plc’s. Troubleshooting...
Forum: LIVE PLC Questions And Answers October 21st, 2019, 05:25 PM
Replies: 18
Views: 1,003
Posted By andepand
Isnít the whole loop executed before the plc...

Isnít the whole loop executed before the plc continues scanning the next statement?
That way it shouldnít matter if youíre looping forward or backward, or am I wrong here?

Offcourse I see the...
Forum: LIVE PLC Questions And Answers October 21st, 2019, 04:03 PM
Replies: 18
Views: 1,003
Posted By andepand
Question The fear of FOR TO and WHILE loops

Hi everybody,

For a while I’ve been wondering, in every plc forum where the use of loops come to discussion I find most people answering that it’s best to stay away from them and that there are...
Forum: LIVE PLC Questions And Answers October 15th, 2019, 04:59 PM
Replies: 3
Views: 449
Posted By andepand
Hi Bob, thanks, I will check it out

Hi Bob, thanks, I will check it out
Forum: LIVE PLC Questions And Answers October 14th, 2019, 03:22 PM
Replies: 3
Views: 449
Posted By andepand
No ideas, anyone..? :utoh:

No ideas, anyone..? :utoh:
Forum: LIVE PLC Questions And Answers October 12th, 2019, 04:58 AM
Replies: 3
Views: 449
Posted By andepand
Cx programmer PRV instruction in ST

I checked the forum, and actually the rest of the internet also, but I canít find an answer to the following.

Iím programming an Omron CJ2M with an MD212 high speed I/O card. I usually do all my...
Forum: LIVE PLC Questions And Answers October 12th, 2019, 04:55 AM
Replies: 8
Views: 3,148
Posted By andepand
Excuse me, I thought I made a new thread, I...

Excuse me, I thought I made a new thread, I didnít mean to highjack yours :p
Forum: LIVE PLC Questions And Answers October 11th, 2019, 08:27 PM
Replies: 8
Views: 3,148
Posted By andepand
Hi, I checked the forum, and actually the...

Hi,

I checked the forum, and actually the rest of the internet also, but I can’t find an answer to the following.

I’m programming an Omron CJ2M with an MD212 high speed I/O card. I usually do...
Forum: LIVE PLC Questions And Answers September 9th, 2019, 02:40 PM
Replies: 12
Views: 328
Posted By andepand
Thanks for your time and advice anyway! For now...

Thanks for your time and advice anyway!
For now Iíll work arround it by moving the data.

If anyone else is familiar with this problem, let me know.
Forum: LIVE PLC Questions And Answers September 9th, 2019, 02:24 PM
Replies: 12
Views: 328
Posted By andepand
Mostly it will mess up the sleekness of my...

Mostly it will mess up the sleekness of my program :D
Forum: LIVE PLC Questions And Answers September 9th, 2019, 01:35 PM
Replies: 12
Views: 328
Posted By andepand
I’m using Ethernet/IP, the data is recieved by...

I’m using Ethernet/IP, the data is recieved by the plc only put in the lowest 8 bits.
Which makes sense I would say, but 0031 is not accepted as an ASCII character
Forum: LIVE PLC Questions And Answers September 9th, 2019, 01:26 PM
Replies: 12
Views: 328
Posted By andepand
I mean the one they used for the keyence manual,...

I mean the one they used for the keyence manual, mine is up to date.
Forum: LIVE PLC Questions And Answers September 9th, 2019, 01:22 PM
Replies: 12
Views: 328
Posted By andepand
That was my last resort. I just cannot inmagine...

That was my last resort. I just cannot inmagine there not being any other solution.
The Keyence is pretty restricted in itís adressing and data settings but the Keyence manual shows it should be...
Forum: LIVE PLC Questions And Answers September 9th, 2019, 12:31 PM
Replies: 12
Views: 328
Posted By andepand
0000000000110001 = Hex 0031 = No string ...

0000000000110001 = Hex 0031 = No string

0011000100000000 = Hex 3100 = String “1”

The data send by the Keyence gives me the upper result.
Forum: LIVE PLC Questions And Answers September 9th, 2019, 12:22 PM
Replies: 12
Views: 328
Posted By andepand
Yes, that I know. I work in ST and D24 is...

Yes, that I know.

I work in ST and D24 is set as STRING. When I view D24 in my program or in watch window, it shows a quotation mark, meaning there’s no string data.

When I view the adress in...
Forum: LIVE PLC Questions And Answers September 9th, 2019, 10:51 AM
Replies: 12
Views: 328
Posted By andepand
Omron CJ2M string data from vision system

Hi Guys,

Question:

I'm using an Omron CJ2M to recieve a 40 character tekst string from a Keyence CV-X 420 vision camera.
The keyence uses two words for one ASCII character which I can not...
Forum: LIVE PLC Questions And Answers July 20th, 2019, 05:01 AM
Replies: 2
Views: 317
Posted By andepand
I have to add (can’t edit my post no more) that...

I have to add (can’t edit my post no more) that products are inserted along the line, on top of eachother. So the last inserted product has a much shorter distance to the end of the line than the...
Forum: LIVE PLC Questions And Answers July 20th, 2019, 03:50 AM
Replies: 2
Views: 317
Posted By andepand
Incremental pulse counters CX programmer

Hi

I have a question regarding the title of this post.

I’m using an Omron CJ2M with an MD212 high speed input expasion and offcourse CX programmer for programming.
I have a working incremental...
Forum: LIVE PLC Questions And Answers July 14th, 2019, 04:21 AM
Replies: 7
Views: 821
Posted By andepand
I was indeed planning on giving the vision system...

I was indeed planning on giving the vision system it’s own line to the switch.
Probably I explained it wrong, the camera actually has no settings for broadcast, unicast or multicast. Just a target...
Forum: LIVE PLC Questions And Answers July 13th, 2019, 01:34 PM
Replies: 7
Views: 821
Posted By andepand
Clear info. Buying an intelligent switch is no...

Clear info. Buying an intelligent switch is no problem but I can’t inmagine it’ll just know what to do out of the box.

Offcourse I will check out available documentation I can find but maybe...
Forum: LIVE PLC Questions And Answers July 13th, 2019, 04:50 AM
Replies: 7
Views: 821
Posted By andepand
I understand the use of VLAN and the ability to...

I understand the use of VLAN and the ability to troubleshoot a network using a managed switch, but I’m having a hard time understanding how multicast and unicast are being handeled by different sorts...