Search: Posts Made By: JaxGTO
Forum: LIVE PLC Questions And Answers October 30th, 2017, 03:37 AM
Replies: 35
Views: 1,730
Posted By JaxGTO
I really need to retire. I cant take it anymore!

I really need to retire. I cant take it anymore!
Forum: LIVE PLC Questions And Answers October 28th, 2017, 10:26 PM
Replies: 5
Views: 213
Posted By JaxGTO
control-H Find: N7:* Replace: N107:* Set...

control-H
Find: N7:*
Replace: N107:*
Set move comment

To copy the date, open each table and select all the data and copy, then open other table go to word 0 and hit paste.
Forum: LIVE PLC Questions And Answers October 27th, 2017, 02:17 PM
Replies: 33
Views: 1,372
Posted By JaxGTO
Dont forget the last two: for Gold and Silver.

Dont forget the last two:
for Gold and Silver.
Forum: LIVE PLC Questions And Answers October 26th, 2017, 03:58 PM
Replies: 14
Views: 454
Posted By JaxGTO
I think it's a left over from when this used to...

I think it's a left over from when this used to be RSView32, before that ControlView and before that it was AdvisorPC. All of those apps you could press a button and hold down but nothing happened...
Forum: LIVE PLC Questions And Answers October 21st, 2017, 06:47 PM
Replies: 11
Views: 345
Posted By JaxGTO
Also if the SLC is a large program you can place...

Also if the SLC is a large program you can place a few SVC instructions about every 100 rungs. The SVC tells it to process messaging during the program scan. But be carful it can add a little to the...
Forum: LIVE PLC Questions And Answers October 21st, 2017, 06:45 PM
Replies: 11
Views: 345
Posted By JaxGTO
I have had to do that before as well. Logic and...

I have had to do that before as well. Logic and SLCs. Seems like if you edit it to many times it get corrupted.
Forum: LIVE PLC Questions And Answers October 20th, 2017, 10:23 PM
Replies: 3
Views: 291
Posted By JaxGTO
I usually use the USB port in the back and...

I usually use the USB port in the back and download the parameters I want to change that was. Also I have used Connected Components Workbench to set them up.
Also if there is a keypad you can just...
Forum: LIVE PLC Questions And Answers October 15th, 2017, 07:50 PM
Replies: 3
Views: 144
Posted By JaxGTO
I personally have 27 different VM's. But I have...

I personally have 27 different VM's. But I have to have WW from 4.2 all the way up to the latest. I even have a Windows 3.11 machine for one customer who wants a change about once every 2 years on an...
Forum: LIVE PLC Questions And Answers October 10th, 2017, 11:36 PM
Replies: 7
Views: 503
Posted By JaxGTO
I remember the << is a bit shift left

I remember the << is a bit shift left
Forum: LIVE PLC Questions And Answers October 3rd, 2017, 11:18 PM
Replies: 10
Views: 525
Posted By JaxGTO
As an SI I have to have every version of Rockwell...

As an SI I have to have every version of Rockwell Wonderware etc. so I have nothing but virtual machines. Easier to backup too. Just copy them off to a removable drive and ur done. Also if my pc...
Forum: LIVE PLC Questions And Answers September 29th, 2017, 04:11 PM
Replies: 9
Views: 703
Posted By JaxGTO
If you use FT Historian or FT Transaction Manager...

If you use FT Historian or FT Transaction Manager (RSSQL) it can use the Logix gateway.
Forum: LIVE PLC Questions And Answers September 29th, 2017, 04:01 PM
Replies: 14
Views: 1,033
Posted By JaxGTO
The help file says you can use <= >= <> and = etc...

The help file says you can use <= >= <> and = etc in a FAL but i couldn't get it to work. If it did you could use that to sum up how many were =0.
Forum: LIVE PLC Questions And Answers September 26th, 2017, 03:24 PM
Replies: 5
Views: 224
Posted By JaxGTO
Maybe a bad install on the servo AOP?

Maybe a bad install on the servo AOP?
Forum: LIVE PLC Questions And Answers September 25th, 2017, 07:30 PM
Replies: 6
Views: 440
Posted By JaxGTO
It depends on the way you access the camera. If...

It depends on the way you access the camera. If it is through a browser then PanelView probably wont work as the browser has no java or other scripting capabilities. But if your camera comes with an...
Forum: LIVE PLC Questions And Answers September 25th, 2017, 07:26 PM
Replies: 10
Views: 381
Posted By JaxGTO
As said before it will convert all of your N7...

As said before it will convert all of your N7 type files to arrays with the same name, but it will also convert your tags to those address and make alias tags to them. So if you have N7:0 with a tag...
Forum: LIVE PLC Questions And Answers September 20th, 2017, 07:39 PM
Replies: 22
Views: 956
Posted By JaxGTO
If it has a 1772-MJ or 1785-MJ module in the...

If it has a 1772-MJ or 1785-MJ module in the bottom of the processor then the program could still be on the EEPROM. But that is only for the Mini 2/02, 2/16 and 2/17 which if it were it would be...
Forum: LIVE PLC Questions And Answers September 15th, 2017, 10:20 PM
Replies: 11
Views: 328
Posted By JaxGTO
I have been slowly converting some of my string...

I have been slowly converting some of my string functions from VB to Structured text. This is perhaps the only reason to use structured text IMO.

Lots of Basic examples for parsing strings on the...
Forum: LIVE PLC Questions And Answers September 11th, 2017, 08:08 PM
Replies: 1
Views: 131
Posted By JaxGTO
On the properties of the button there is a...

On the properties of the button there is a selection for Function key in the lower left. Only one button can be assigned to a function key so you may have to change them around if it didn't assign it...
Forum: LIVE PLC Questions And Answers September 11th, 2017, 08:04 PM
Replies: 1
Views: 190
Posted By JaxGTO
Knowing ladder logic is a good start no matter...

Knowing ladder logic is a good start no matter what PLC. Logic is logic.
Knowing all the more common HMI's is good no matter the PLC, a tag is a tag, but making nice screens that are logically and...
Forum: LIVE PLC Questions And Answers September 11th, 2017, 07:57 PM
Replies: 26
Views: 1,454
Posted By JaxGTO
I have asked them about it twice and I still...

I have asked them about it twice and I still don't really know what it is.

I know its option #2 on tech support, so that can't be good.
Forum: LIVE PLC Questions And Answers September 6th, 2017, 08:58 PM
Replies: 3
Views: 191
Posted By JaxGTO
All of the Wonderware distributors have an FTP...

All of the Wonderware distributors have an FTP site where you can download the ISO images. They even have the old stuff. Give them a call and I am sure they would be happy to give you the site...
Forum: LIVE PLC Questions And Answers September 2nd, 2017, 04:44 PM
Replies: 45
Views: 2,677
Posted By JaxGTO
I prefer the old fashion touch, ...

I prefer the old fashion touch,
https://encrypted-tbn0.gstatic.com/images?q=tbn:ANd9GcSOECmtP9rC5g9QjauypkedGoBPma-P0en9yp7spZtqGh0HVS6CBA
Forum: LIVE PLC Questions And Answers August 25th, 2017, 04:26 AM
Replies: 8
Views: 862
Posted By JaxGTO
I got that today too. Still trying to figure out...

I got that today too. Still trying to figure out what the problem is through all the Politically Correct softening and a$$ covering.

Geez just tell us what you screwed up and let us fix it!
Forum: LIVE PLC Questions And Answers August 23rd, 2017, 02:42 PM
Replies: 2
Views: 298
Posted By JaxGTO
I typically set them to a roll over counter then...

I typically set them to a roll over counter then build a master totalizer. Then when metering grab a snap shot of the totalizer and open the batch valve until it get to a SP-Preact number and close...
Forum: LIVE PLC Questions And Answers August 22nd, 2017, 01:26 PM
Replies: 3
Views: 215
Posted By JaxGTO
I made a plant wide application that uses the...

I made a plant wide application that uses the ME_TerminalInfo ActiveX on a startup screen to get the IP address of the terminal. It is just triggered by a 1 in the Enable word. Then it fires a...