Search: Posts Made By: gclshortt
Forum: LIVE PLC Questions And Answers November 16th, 2018, 02:15 PM
Replies: 23
Views: 805
Posted By gclshortt
+1 Do-more Software + AdvancedHMI for the HMI ...

+1 Do-more Software
+ AdvancedHMI for the HMI
https://sourceforge.net/projects/advancedhmi/

https://accautomation.ca/create-a-plc-with-hmi-training-and-learning-environment-free/

Here is a...
Forum: LIVE PLC Questions And Answers November 15th, 2018, 05:28 PM
Replies: 6
Views: 180
Posted By gclshortt
Another option is to use AdvancedHMI. ...

Another option is to use AdvancedHMI.
https://sourceforge.net/projects/advancedhmi/
You would get the information with the drivers that have been written for the PLC and then automate excel from...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 02:24 PM
Replies: 15
Views: 231
Posted By gclshortt
Create a picture ...

Create a picture
http://www.plctalk.net/qanda/showthread.php?t=104878

http://www.plctalk.net/qanda/showthread.php?t=99639

Send Email
http://www.plctalk.net/qanda/showthread.php?t=115204
...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 01:54 PM
Replies: 2
Views: 93
Posted By gclshortt
http://www.htz.com.tw/files/cognex/manual/dataman_...

http://www.htz.com.tw/files/cognex/manual/dataman_CommunicationsAndProgramming.pdf

"SetMatchString: Changing this tag from 0 to 1 will cause the set match string operation to be invoked. The match...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 10:28 AM
Replies: 1
Views: 49
Posted By gclshortt
https://www.youtube.com/watch?v=hKUUDytC5WY ...

https://www.youtube.com/watch?v=hKUUDytC5WY

The above link may help you out.
Regards,
Forum: LIVE PLC Questions And Answers November 14th, 2018, 10:09 AM
Replies: 4
Views: 78
Posted By gclshortt
Thanks for the update.

Thanks for the update.
Forum: LIVE PLC Questions And Answers November 14th, 2018, 08:02 AM
Replies: 6
Views: 181
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=1079...

http://www.plctalk.net/qanda/showthread.php?t=107979

http://www.plctalk.net/qanda/showthread.php?t=77541

http://www.plctalk.net/qanda/showthread.php?t=71500

The above links may help you out....
Forum: LIVE PLC Questions And Answers November 14th, 2018, 07:54 AM
Replies: 4
Views: 78
Posted By gclshortt
Have you made a connection before using this...

Have you made a connection before using this computer?
What is the operating system?
Under the "Device Manager" in windows, do you see the com port associated with the usb device?
You want to test...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 07:47 AM
Replies: 36
Views: 1,085
Posted By gclshortt
Having a law is one thing... Enforcing the law...

Having a law is one thing...
Enforcing the law is another...

Many tragic useless endings on the topic.
Forum: LIVE PLC Questions And Answers November 13th, 2018, 03:40 PM
Replies: 3
Views: 153
Posted By gclshortt
+1 Diat150 Polyvinylchloride (PVC)/Polyamide...

+1 Diat150
Polyvinylchloride (PVC)/Polyamide (Nylon) is what you are looking for the jacket material. An alternative would be XLPE (Cross-linked Polyethylene)

Regards,
Forum: LIVE PLC Questions And Answers November 8th, 2018, 08:16 AM
Replies: 4
Views: 118
Posted By gclshortt
http://www.techtrends.ru/docs/omron/sistemy_avtoma...

http://www.techtrends.ru/docs/omron/sistemy_avtomatizatsii/programmiruemye_logicheskie_kontrollery/modulnye_pls/cqm1h/CQM1H_Programmable_Controller_Catalogue_P050-E1-07-ds.pdf
...
Forum: LIVE PLC Questions And Answers November 8th, 2018, 07:56 AM
Replies: 13
Views: 563
Posted By gclshortt
The capacitive proximity sensor is the sensor for...

The capacitive proximity sensor is the sensor for the application.
What about using something with a push button teach function? Similar to the following:...
Forum: LIVE PLC Questions And Answers November 7th, 2018, 03:35 PM
Replies: 4
Views: 151
Posted By gclshortt
It looks like the T21 and not T23 on rung 13 keep...

It looks like the T21 and not T23 on rung 13 keep the timer 21 sealed. Make the branch for T21 and not T23 between the Var_Dn and NB_Scroll contacts. This will then reset the timer and everything...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 03:30 PM
Replies: 9
Views: 315
Posted By gclshortt
Ebay has all of the options for host link units. ...

Ebay has all of the options for host link units.
https://www.ebay.ca/sch/i.html?_from=R40&_trksid=m570.l1313&_nkw=C200H-IP007&_sacat=0...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 06:32 AM
Replies: 9
Views: 315
Posted By gclshortt
1 - This may work provided that the battery is...

1 - This may work provided that the battery is still good.
http://www.omronkft.hu/nostree/pdfs/plc/c200h/w218-e1-6.pdf
2 - In order to program you will need a host link adapter for this PLC....
Forum: LIVE PLC Questions And Answers November 5th, 2018, 03:40 PM
Replies: 2
Views: 121
Posted By gclshortt
Try AirportPressure.Value =...

Try
AirportPressure.Value = rec1.field(0).Value
Or
AirportPressure.Value = rec1.fields("Value").value

Regards,
Forum: LIVE PLC Questions And Answers November 5th, 2018, 03:32 PM
Replies: 11
Views: 460
Posted By gclshortt
+1 lfe https://www.automationdirect.com/stride ...

+1 lfe
https://www.automationdirect.com/stride

The above link may help you out.
Regards,
Forum: LIVE PLC Questions And Answers November 5th, 2018, 03:29 PM
Replies: 4
Views: 246
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=4912...

http://www.plctalk.net/qanda/showthread.php?t=49120

The above thread may help you out.
Regards,
Forum: LIVE PLC Questions And Answers November 1st, 2018, 11:27 AM
Replies: 2
Views: 126
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=9341...

http://www.plctalk.net/qanda/showthread.php?t=93413&page=2

http://www.plctalk.net/qanda/showthread.php?t=105099

http://www.plctalk.net/qanda/showthread.php?t=99639

The above links may help...
Forum: LIVE PLC Questions And Answers November 1st, 2018, 08:12 AM
Replies: 3
Views: 146
Posted By gclshortt
http://www.plctalk.net/qanda/showthread.php?t=1072...

http://www.plctalk.net/qanda/showthread.php?t=107286

http://www.plctalk.net/qanda/showthread.php?t=89342

The above threads may help you out.
Regards,
Forum: LIVE PLC Questions And Answers October 31st, 2018, 05:12 PM
Replies: 15
Views: 651
Posted By gclshortt
https://accautomation.ca/building-a-plc-program-th...

https://accautomation.ca/building-a-plc-program-that-you-can-be-proud-of-part-1/

The above link may help you out.
Regards,
Forum: LIVE PLC Questions And Answers October 30th, 2018, 11:44 AM
Replies: 4
Views: 202
Posted By gclshortt
Is there any other information that you can give...

Is there any other information that you can give us?
Picture of the machine?
Make, model, manufacturer?

Regards,
Forum: LIVE PLC Questions And Answers October 30th, 2018, 11:25 AM
Replies: 10
Views: 331
Posted By gclshortt
If the scan of the PLC is not quick enough for...

If the scan of the PLC is not quick enough for your application, you will have to get the correct CPU with the built in HSC. (DC inputs) Expansion IO can then be added for the AC input points.
...
Forum: LIVE PLC Questions And Answers October 30th, 2018, 11:04 AM
Replies: 10
Views: 331
Posted By gclshortt
https://literature.rockwellautomation.com/idc/grou...

https://literature.rockwellautomation.com/idc/groups/literature/documents/um/1762-um001_-en-p.pdf

Put an expansion card on the unit rated for 24vdc.
See 1762 Expansion I/O in the above manual.
...
Forum: LIVE PLC Questions And Answers October 30th, 2018, 09:45 AM
Replies: 2
Views: 123
Posted By gclshortt
http://industrial.omron.com.br/uploads/arquivos/E5...

http://industrial.omron.com.br/uploads/arquivos/E5AN.pdf
I would look at 4-2 Alarm Hysteresis in the above manual.
If you program in an alarm hysteresis of 30 for alarm 2 this should work for you....