Search: Posts Made By: Dravik
Forum: LIVE PLC Questions And Answers November 5th, 2018, 03:26 PM
Replies: 4
Views: 325
Posted By Dravik
Well, If you only have a handful of values to...

Well, If you only have a handful of values to deal with and don't need to do this often(ie, not every 10ms). You could put them into an array w/ the hours as one dimension and a numeric rep of the...
Forum: LIVE PLC Questions And Answers November 5th, 2018, 02:52 PM
Replies: 4
Views: 199
Posted By Dravik
So, Are these inputs voltage or current inputs?...

So, Are these inputs voltage or current inputs? If I remember right, those cards allowed you to set each 'pair' of inputs (0,1 2,3 4,5 etc...) to either voltage or current and differential or single...
Forum: LIVE PLC Questions And Answers October 26th, 2018, 02:35 PM
Replies: 17
Views: 698
Posted By Dravik
I use Single (External) as my Trigger Type for...

I use Single (External) as my Trigger Type for PLC driven application.
Forum: LIVE PLC Questions And Answers October 26th, 2018, 01:51 PM
Replies: 17
Views: 698
Posted By Dravik
What version of the FW are you running on the...

What version of the FW are you running on the readers?
Forum: LIVE PLC Questions And Answers October 26th, 2018, 01:46 PM
Replies: 17
Views: 698
Posted By Dravik
1.28 , I see .triggerack come high after I set...

1.28 , I see .triggerack come high after I set both .TriggerEnable and .Trigger and stay high until I unset .Trigger.
Forum: LIVE PLC Questions And Answers October 26th, 2018, 01:30 PM
Replies: 17
Views: 698
Posted By Dravik
Hmm, I'm also using the AOP, must be a different...

Hmm, I'm also using the AOP, must be a different version, but when I put .TriggerEnable high and toggle .Trigger I get the scanner to trigger just fine.

I'm working with a Dataman 362.
Forum: LIVE PLC Questions And Answers October 25th, 2018, 11:20 AM
Replies: 8
Views: 835
Posted By Dravik
We do this w/ heating/cooling blocks using the...

We do this w/ heating/cooling blocks using the SRTP instruction. I use the PID loop output to feed the IN parameter of the SRTP block.

But yeah, you don't need to use a PID loop for this if you...
Forum: LIVE PLC Questions And Answers October 24th, 2018, 01:13 PM
Replies: 8
Views: 267
Posted By Dravik
Well, you can use a momentary button w/ images...

Well, you can use a momentary button w/ images set.
Forum: LIVE PLC Questions And Answers October 24th, 2018, 10:23 AM
Replies: 9
Views: 230
Posted By Dravik
I generally create a timed task instead of using...

I generally create a timed task instead of using a timer, but that works.
Forum: LIVE PLC Questions And Answers October 24th, 2018, 10:17 AM
Replies: 9
Views: 230
Posted By Dravik
You can also take a look at the PIDE instruction...

You can also take a look at the PIDE instruction which has some extended features.
Forum: LIVE PLC Questions And Answers October 23rd, 2018, 08:10 AM
Replies: 7
Views: 258
Posted By Dravik
There is, for the Micrologix 1400 that is 7...

There is, for the Micrologix 1400 that is 7 modules per the RA specs. I've not personally seen it done offhand.
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 04:50 PM
Replies: 10
Views: 293
Posted By Dravik
Essentially what you are doing in that setup is...

Essentially what you are doing in that setup is this -

This assumes each subnet range is assigned to a unique VLAN -

1 port from the switch, setup as a trunk, allowed to pass all the 'tagged'...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 04:45 PM
Replies: 15
Views: 679
Posted By Dravik
You can... But this does add another point of...

You can... But this does add another point of failure and consider if your future self will hate you for it.

Fiber good.
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 04:28 PM
Replies: 10
Views: 293
Posted By Dravik
So, I've done this before but I had help from the...

So, I've done this before but I had help from the IT folks.
What I ended up doing was getting a trunk port setup for my main lan connection and then using the intel nic drivers to setup virtual...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 12:39 PM
Replies: 10
Views: 355
Posted By Dravik
If we're talking thermal transfer, I've used...

If we're talking thermal transfer, I've used Zebra and Domino printers pretty extensively. Mostly Zebra (common printer at the plant).

Most of the Zebra printers have on-board memory and can store...
Forum: LIVE PLC Questions And Answers October 16th, 2018, 12:20 PM
Replies: 11
Views: 367
Posted By Dravik
Here's the one I use - Works great. ...

Here's the one I use - Works great.
https://pogostick.net/~pnh/ntpasswd/

You could also, assuming you had a backup, just delete the SAM file. This assumes you don't care about any of the accounts.
Forum: LIVE PLC Questions And Answers October 12th, 2018, 03:14 PM
Replies: 4
Views: 206
Posted By Dravik
I have had to reflash a panel(with the same...

I have had to reflash a panel(with the same version as before) that did that to me.
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 10:56 AM
Replies: 9
Views: 557
Posted By Dravik
Regulatory and AHJ requirements outside of normal...

Regulatory and AHJ requirements outside of normal compliance requirements. (IE, for example compliance with CFR 21 Part 11 for Pharma industries)

Safety requirements
Ergonomic Requirements...
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 03:41 PM
Replies: 4
Views: 278
Posted By Dravik
Yes but it depends on what you want to do w/ it. ...

Yes but it depends on what you want to do w/ it.
Just start/stop via digital i/o and feed it an analog speed ref, no worries.
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 12:39 PM
Replies: 8
Views: 337
Posted By Dravik
Have you put a scope on the sensor itself?

Have you put a scope on the sensor itself?
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 12:03 PM
Replies: 8
Views: 337
Posted By Dravik
So, depending on your de-bounce time, probably...

So, depending on your de-bounce time, probably fine there.
If I didn't have a high-speed counter module, I would probably put some secondary logic in to count the number of time the sensor goes...
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 11:28 AM
Replies: 8
Views: 337
Posted By Dravik
How fast does your sensor switch? At 200ft/min...

How fast does your sensor switch? At 200ft/min how long is your part in front of the sensor for?

Edit: What is the RPI of this module set to and what kind of task is your counting logic executing...
Forum: LIVE PLC Questions And Answers October 1st, 2018, 04:14 PM
Replies: 1
Views: 282
Posted By Dravik
Sure, here you go.

Sure, here you go.
Forum: LIVE PLC Questions And Answers September 28th, 2018, 12:19 PM
Replies: 15
Views: 1,040
Posted By Dravik
Ahh fun, yeah if no server is listed, no ldap...

Ahh fun, yeah if no server is listed, no ldap funtimes.

I'd guess the username/passwords you have are actually local users. So yeah, those would work w/out the connection.

I don't think these...
Forum: LIVE PLC Questions And Answers September 26th, 2018, 04:26 PM
Replies: 15
Views: 1,040
Posted By Dravik
Well, and they may not have setup individual...

Well, and they may not have setup individual users in the directory. They may just be referencing windows-linked groups which may or may not display the domain.