Search: Posts Made By: mk42
Forum: LIVE PLC Questions And Answers April 2nd, 2020, 07:20 AM
Replies: 6
Views: 213
Posted By mk42
As they said, only the CU has an IP. You don't...

As they said, only the CU has an IP. You don't assign IP addresses to the motor modules/line modules/etc. They are on DriveCliq, which uses cables that look like Ethernet cables, but is actually...
Forum: LIVE PLC Questions And Answers April 1st, 2020, 09:19 AM
Replies: 15
Views: 834
Posted By mk42
Not personally an integrator, but my thoughts: ...

Not personally an integrator, but my thoughts:



To me, it seems fair to charge for remote support, if you are up front about it. If you say "that's a great question, and something I can help...
Forum: LIVE PLC Questions And Answers March 31st, 2020, 07:22 AM
Replies: 15
Views: 442
Posted By mk42
FYI, for every PLC I've ever used, "Upload" means...

FYI, for every PLC I've ever used, "Upload" means from PLC to PC, and "Download" means from PC to PLC. Might vary brand by brand, though.


FYI as well that Siemens does offer an API called...
Forum: LIVE PLC Questions And Answers March 30th, 2020, 01:14 PM
Replies: 6
Views: 366
Posted By mk42
Modbus question

Got a PM from a user "shwe", thought it should be a thread instead:




RS485 conversion is completely different to the TCP vs UDP question. What are you trying to do?
Forum: LIVE PLC Questions And Answers March 30th, 2020, 10:19 AM
Replies: 17
Views: 611
Posted By mk42
Probably the best solution, good luck!

Probably the best solution, good luck!
Forum: LIVE PLC Questions And Answers March 30th, 2020, 10:19 AM
Replies: 17
Views: 611
Posted By mk42
I've seen some Siemens devices that have a VD...

I've seen some Siemens devices that have a VD option (variable distance). Instead of the more common copper or fiber as the Ethernet medium, it lets you use 2 wire serial cables. That's using it in...
Forum: LIVE PLC Questions And Answers March 26th, 2020, 12:25 PM
Replies: 24
Views: 1,055
Posted By mk42
The key thing for our IT team is that the host PC...

The key thing for our IT team is that the host PC is NEVER allowed on the company office network, only the guest network. The VM is encrypted, so the data is secure in place. There is really minimal...
Forum: LIVE PLC Questions And Answers March 26th, 2020, 10:04 AM
Replies: 24
Views: 1,055
Posted By mk42
The mapping works out pretty much the same in the...

The mapping works out pretty much the same in the Siemens world. Bridged lets you do network scanning/browsing, and changing device names. NAT might work if the HW is set up, and you know all the...
Forum: LIVE PLC Questions And Answers March 25th, 2020, 08:38 PM
Replies: 15
Views: 621
Posted By mk42
I guess I was one off, whichever. I think DNS...

I guess I was one off, whichever. I think DNS showed up in the 1200 somewhere along the way as well. New FW def does add OPC UA to the 1200, which is nice.

I've heard that dealing with...
Forum: LIVE PLC Questions And Answers March 25th, 2020, 08:21 PM
Replies: 24
Views: 1,055
Posted By mk42
100% full control, which is why our team likes it...

100% full control, which is why our team likes it so much. IT literally doesn't even know the laptop exists, they just know that I'm running their VM on SOMETHING. I mean, they probably could know,...
Forum: LIVE PLC Questions And Answers March 25th, 2020, 03:41 PM
Replies: 15
Views: 621
Posted By mk42
Latest FW for 1200 (v4.4, requires v16) allows...

Latest FW for 1200 (v4.4, requires v16) allows for secure communication.
Forum: LIVE PLC Questions And Answers March 25th, 2020, 03:40 PM
Replies: 24
Views: 1,055
Posted By mk42
Use one computer. I put control programs in host...

Use one computer. I put control programs in host (and VMs as needed). IT issued a VM with all company stuff (outlook, VPN, etc). Main comp can never be on company office network, but IT only gets...
Forum: LIVE PLC Questions And Answers March 24th, 2020, 09:19 AM
Replies: 2
Views: 235
Posted By mk42
The 200 -> 1200 converter isn't great, because...

The 200 -> 1200 converter isn't great, because there are some concepts in the 200 that don't map over exactly, but it's better than nothing. 1200s convert to 1500s almost 100% with minimal effort.
...
Forum: LIVE PLC Questions And Answers March 23rd, 2020, 09:35 AM
Replies: 17
Views: 854
Posted By mk42
Something to watch out for, although it probably...

Something to watch out for, although it probably won't affect IO traffic:


PRP adds a few bytes of header to the normal Ethernet frame. If the packet is already max size (1500ish bytes), and...
Forum: LIVE PLC Questions And Answers March 23rd, 2020, 07:32 AM
Replies: 15
Views: 757
Posted By mk42
Here in the US, the average PLC "programmer" at...

Here in the US, the average PLC "programmer" at most plants is a 60 yr old electrician/maintenance guy who resents the fact that he has to use a computer at all. Employers don't pay enough to hire...
Forum: LIVE PLC Questions And Answers March 22nd, 2020, 07:00 PM
Replies: 16
Views: 777
Posted By mk42
Siemens S7-300 (if it has Ethernet), 1200, and...

Siemens S7-300 (if it has Ethernet), 1200, and 1500 all can include custom web pages.
Forum: LIVE PLC Questions And Answers March 22nd, 2020, 09:24 AM
Replies: 17
Views: 854
Posted By mk42
First choice solution would be to fix the...

First choice solution would be to fix the existing wifi. That can be tricky though, physics can be cranky.

There are other redundancy protocols that could make more sense. PRP (Parallel...
Forum: LIVE PLC Questions And Answers March 20th, 2020, 07:59 AM
Replies: 9
Views: 393
Posted By mk42
As Jesper said, any IO devices (VFDs included)...

As Jesper said, any IO devices (VFDs included) would have I and Q addresses. DBs are the internal memory of the PLC to remember things from scan to scan. In your case, it looks like DB140 holds the...
Forum: LIVE PLC Questions And Answers March 20th, 2020, 07:52 AM
Replies: 3
Views: 312
Posted By mk42
Doesn't directly address your question, but: ...

Doesn't directly address your question, but:


1) Data signals should intersect power lines at 90 degree angles, parallel right next to each other is bad. I think I've seen guidelines that if...
Forum: LIVE PLC Questions And Answers March 20th, 2020, 07:46 AM
Replies: 2
Views: 155
Posted By mk42
S7-300 cards often have separate power from the...

S7-300 cards often have separate power from the main CPU. Power must usually be wired to each card.
Forum: LIVE PLC Questions And Answers March 20th, 2020, 07:44 AM
Replies: 14
Views: 529
Posted By mk42
If you had read either the readme or the release...

If you had read either the readme or the release documents link at the v5.6 trial software download site, you would have seen that it supports:



MS Windows 7 (64bit) Professional, Enterprise...
Forum: LIVE PLC Questions And Answers March 19th, 2020, 09:10 AM
Replies: 41
Views: 1,513
Posted By mk42
Pretty poor results are what the early versions...

Pretty poor results are what the early versions of Portal are known for (first version was v10.5, we're at v16 now about 10 years later). Good luck!
Forum: LIVE PLC Questions And Answers March 19th, 2020, 09:08 AM
Replies: 10
Views: 611
Posted By mk42
that's the story I heard, at any rate

that's the story I heard, at any rate
Forum: LIVE PLC Questions And Answers March 19th, 2020, 09:08 AM
Replies: 14
Views: 529
Posted By mk42
They'll usually approve you eventually, but it...

They'll usually approve you eventually, but it can take a couple days under normal circumstances. I wouldn't be surprised to hear it take longer these days.



Essentially, due to legal...
Forum: LIVE PLC Questions And Answers March 18th, 2020, 01:06 PM
Replies: 41
Views: 1,513
Posted By mk42
Most licenses can be moved around via either USB...

Most licenses can be moved around via either USB stick or over the network. Only in very rare/old cases (like v10.5-V11 Basic) are the licenses not transferable. Heck, legally I think you can even...